Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 297

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

A118G Single Nucleotide Polymorphism of Human μ-Opioid Receptor Gene Influences Pain Perception and Patient-controlled Intravenous Morphine Consumption after Intrathecal Morphine for Postcesarean Analgesia

Open access
Sia, Alex T., Lim, Yvonne, Lim, Eileen C. P., Goh, Rachelle W. C., Law, Hai Yang, Landau, Ruth, Teo, Yik-ying, Tan, Ene Choo·2008·Anesthesiology

Abstract

Background: Previous studies have shown that genetic variability at position 118 of the human mu-opioid receptor gene altered patients' response to intravenous morphine. The purpose of this study was to investigate whether this polymorphism contributes to the variability in response to morphine for postcesarean analgesia. Methods: After investigators obtained informed consent, 588 healthy women received 0.1 mg intrathecal morphine for postcesarean analgesia. Their blood samples were genotyped for the A118G polymorphism-A118 homozygous (AA), heterozygous (AG), or homozygous for the G allele (GG). Pain scores, the severity of nausea and vomiting, the incidence of pruritus, and the total self-administered intravenous morphine were recorded for the first 24 postoperative hours. Results: Two hundred seventy women (46%) were AA, 234 (40%) were AG, and 82 (14%) were GG. The 24-h self-administered intravenous morphine consumption was lowest in the AA group (P = 0.001; mean, 5.9; 95% confidence interval, 5.1-6.8) versus the AG (8.0; 6.9-9.1) and GG groups (9.4; 7.3-11.5). Pain scores were lowest in the AA group and highest in the GG group, with a statistically significant difference detected between AA, AG, and GG (P = 0.049). Total morphine consumption was also influenced by patients' age and paying status. AA group was associated with the highest incidence of nausea (26 of 272 [9.6%]; P = 0.02) versus the other two groups (13 of 234 [5.6%] and 1 of 82 [1.2%] for AG and GG, respectively). Conclusion: Genetic variation at position 118 of the mu-opioid receptor is associated with interindividual differences in pain scores, self-administered intravenous morphine, and the incidence of nausea postoperatively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e318182af21

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 297

Metadata

Authors
Sia, A. T., Lim, Y., Lim, E. C. P., Goh, R. W. C., Law, H. Y., Landau, R., Teo, Y.-Y., & Tan, E. C.
Venue
Anesthesiology
Published
2008-09-01
Volume
109
Issue
3
Pages
520-526
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1974645621
Cited by
297
References
16
FWCI
22.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A118G Single Nucleotide Polymorphism of Human μ-Opioid Receptor Gene Influences Pain Perception and Patient-controlled Intravenous Morphine Consumption after Intrathecal Morphine for Postcesarean Analgesia. https://app.cochat.ai/papers/10.1097/aln.0b013e318182af21
The paper
Sia, A. T., Lim, Y., Lim, E. C. P., Goh, R. W. C., Law, H. Y., Landau, R., Teo, Y.-Y., & Tan, E. C. (2008). A118G Single Nucleotide Polymorphism of Human μ-Opioid Receptor Gene Influences Pain Perception and Patient-controlled Intravenous Morphine Consumption after Intrathecal Morphine for Postcesarean Analgesia. Anesthesiology. https://doi.org/10.1097/aln.0b013e318182af21

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.