Noninvasive Temperature Monitoring in Postanesthesia Care Units
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background: Initial postoperative core temperature is a physician and hospital performance measure. However, the extent to which core temperature changes during emergence from anesthesia and transport from the operating room to the postanesthesia care unit (PACU) remains unknown. Similarly, the accuracy of many noninvasive temperature-monitoring methods used in the PACU has yet to be quantified. This study, therefore, quantified the change in core temperature occurring during emergence and transport and evaluated the accuracy and precision of eight noninvasive thermometers in the PACU. Methods: In 50 patients having laparoscopic surgery, the authors measured temperatures upon PACU arrival and 30 and 60 min thereafter. Monitoring methods included oral, axillary, temporal artery, forehead skin-surface, forehead liquid-crystal display, infrared aural canal, deep forehead, and deep chest. Bladder temperature was used as the reference and was also measured at the end of surgery. The primary outcome was agreement between individual temperatures from each method and bladder temperature in the PACU. A priori, the authors chose 0.5 degrees C as a clinically important temperature deviation. Results: Bladder temperature increased 0.2 +/- 0.3 degrees C (95% confidence interval 0.1 to 0.3 degrees C), P < 0.001, during transport. None of the tested noninvasive thermometers was consistently within 0.5 degrees C of bladder temperature. However, oral, deep forehead, and temporal artery temperatures were significantly better than other methods and agreed reasonably well with bladder temperature. Conclusions: Invasive temperature monitoring available intraoperatively is more accurate than any generally available postoperative methods. Physician performance measures should therefore not be based exclusively on postoperative temperatures. Among the generally available postoperative monitoring methods, electronic oral thermometry appears to be the best.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Temperature Monitoring and Perioperative Thermoregulation
Sessler, D. I., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31817f6d76 · Cited by 758 · cited 1×
“sites, including the urinary bladder or rectum, reflects core temperature if certain precautions are taken.(10)”
BackgroundSelf-citation
Cited by
Perioperative thermoregulation and heat balance
Sessler, D. I. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00981-2 · Cited by 593
Self-citationNiven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1150 · Cited by 240
Core Temperature Measurement—Principles of Correct Measurement, Problems, and Complications
Hymczak, H., Gołąb, A., Mendrala, K., Plicner, D., Darocha, T., Podsiadło, P., Hudziak, D., Gocoł, R., & Kosiński, S. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph182010606 · Cited by 161
“The preferred place for oral temperature measurement is the sublingual pocket [6,13,15].”
BackgroundAn Evaluation of a Zero-Heat-Flux Cutaneous Thermometer in Cardiac Surgical Patients
Eshraghi, Y., Nasr, V., Parra-Sanchez, I., Van Duren, A., Botham, M., Santoscoy, T., & Sessler, D. I. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000319 · Cited by 161
Self-citationChen, H.-Y., Chen, A., & Chen, C. (2020) · Sensors · doi:10.3390/s20102885 · Cited by 139
“[39] reported a 2 ◦C difference in forehead temperature, as measured using an IRT, and the reference value was the bladder temperature.”
Method
Metadata
- Authors
- Langham, G. E., Maheshwari, A., Contrera, K., You, J., Mascha, E., & Sessler, D. I.
- Venue
- Anesthesiology
- Published
- 2009-07-01
- Volume
- 111
- Issue
- 1
- Pages
- 90-96
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2050950040
- Cited by
- 77
- References
- 4
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.