Routine Clinical Practice Effectiveness of the Glidescope in Difficult Airway Management: An Analysis of 2,004 Glidescope Intubations, Complications, and Failures from Two Institutions
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Introduction: The Glidescope video laryngoscope has been shown to be a useful tool to improve laryngeal view. However, its role in the daily routine of airway management remains poorly characterized. Methods: This investigation evaluated the use of the Glidescope at two academic medical centers. Electronic records from 71,570 intubations were reviewed, and 2,004 cases were identified where the Glidescope was used for airway management. We analyzed the success rate of Glidescope intubation in various intubation scenarios. In addition, the incidence and character of complications associated with Glidescope use were recorded. Predictors of Glidescope intubation failure were determined using a logistic regression analysis. Results: Overall success for Glidescope intubation was 97% (1,944 of 2,004). As a primary technique, success was 98% (1,712 of 1,755), whereas success in patients with predictors of difficult direct laryngoscopy was 96% (1,377 of 1,428). Success for Glidescope intubation after failed direct laryngoscopy was 94% (224 of 239). Complications were noticed in 1% (21 of 2,004) of patients and mostly involved minor soft tissue injuries, but major complications, such as dental, pharyngeal, tracheal, or laryngeal injury, occurred in 0.3% (6 of 2,004) of patients. The strongest predictor of Glidescope failure was altered neck anatomy with presence of a surgical scar, radiation changes, or mass. Conclusion: These data demonstrate a high success rate of Glidescope intubation in both primary airway management and rescue-failed direct laryngoscopy. However, Glidescope intubation is not always successful and certain predictors of failure can be identified. Providers should maintain their competency with alternate methods of intubation, especially for patients with neck pathology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Difficult tracheal intubation: a retrospective study
SAMSOON, G. L. T., & YOUNG, J. R. B. (1987) · Anaesthesia · doi:10.1111/j.1365-2044.1987.tb04039.x · Cited by 1,584
Emergency Tracheal Intubation: Complications Associated with Repeated Laryngoscopic Attempts
Mort, T. C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000122825.04923.15 · Cited by 995
Shiga, T., Wajima, Z., Inoue, T., & Sakamoto, A. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00027 · Cited by 902
Management of the Difficult Airway: A Closed Claims Analysis
Peterson, G. N., Domino, K. B., Caplan, R. A., Posner, K. L., Lee, L. A., & Cheney, F. W. (2005) · Anesthesiology · doi:10.1097/00000542-200507000-00009 · Cited by 852
Morbid Obesity and Tracheal Intubation
Brodsky, J. B., Lemmens, H. J. M., Brock-Utne, J. G., Vierra, M., & Saidman, L. J. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200203000-00047 · Cited by 640
Early clinical experience with a new videolaryngoscope (GlideScope®) in 728 patients
Cooper, R. M., Pacey, J. A., Bishop, M. J., & McCluskey, S. A. (2005) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03027728 · Cited by 562
Prediction and Outcomes of Impossible Mask Ventilation: A Review of 50,000 Anesthetics
Kheterpal, S., Martin, L., Shanks, A. M., & Tremper, K. K. (2009) · Anesthesiology · doi:10.1097/aln.0b013e31819b5b87 · Cited by 467
Self-citationArné, J., Descoins, P., Fusciardi, J., Ingrand, P., Ferrier, B., Boudigues, D., & Ariès, J. (1998) · British Journal of Anaesthesia · doi:10.1093/bja/80.2.140 · Cited by 401
The GlideScope® Video Laryngoscope: randomized clinical trial in 200 patients
Sun, D. A., Warriner, C. B., Parsons, D. G., Klein, R., Umedaly, H. S., & Moult, M. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei041 · Cited by 359
Use of a new videolaryngoscope (GlideScope®) in the management of a difficult airway
Cooper, R. M. (2003) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03018651 · Cited by 244
Cited by
Updated by the Committee on Standards and Practice Parameters, Apfelbaum, J. L., Hagberg, C. A., Caplan, R. A., Blitt, C. D., Connis, R. T., Nickinovich, D. G., Hagberg, C. A., The previous update was developed by the American Society of Anesthesiologists Task Force on Difficult Airway Management, Caplan, R. A., et al. (2013) · Anesthesiology · doi:10.1097/aln.0b013e31827773b2 · Cited by 2,559
Apfelbaum, J. L., Hagberg, C. A., Connis, R. T., Abdelmalak, B. B., Agarkar, M., Dutton, R. P., Fiadjoe, J. E., Greif, R., Klock, P. A., Mercier, D., et al. (2022) · Anesthesiology · doi:10.1097/aln.0000000000004002 · Cited by 1,340
Advanced trauma life support (ATLS®): The ninth edition
The ATLS Subcommittee, A. C. O. S. C. O. T. (2013) · Journal of Trauma and Acute Care Surgery · doi:10.1097/ta.0b013e31828b82f5 · Cited by 733
Dort, J. C., Farwell, D. G., Findlay, M., Huber, G. F., Kerr, P., Shea-Budgell, M. A., Simon, C., Uppington, J., Zygun, D., Ljungqvist, O., et al. (2017) · JAMA Otolaryngology–Head & Neck Surgery · doi:10.1001/jamaoto.2016.2981 · Cited by 527
Apfelbaum, J. L., Hagberg, C. A., Connis, R. T., Abdelmalak, B., Agarkar, M., Dutton, R. P., Fiadjoe, J. E., Greif, R. T., Klock, P. A., Mercier, D. W., et al. (2022) · doi:10.48350/161339 · Cited by 526
Complications and failure of airway management
Cook, T. M., & MacDougall-Davis, S. R. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes393 · Cited by 525
Griesdale, D. E. G., Liu, D., McKinney, J., & Choi, P. T. (2012) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-011-9620-5 · Cited by 363
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
“Equally, there is also some evidence that DL-facilitated intubation may succeed should primary use of some of these same alternatives fail.(78,79) As such, an argument can be made that these alternative devices should complement and not necessarily replace DL at this time.”
BackgroundAziz, M. F., Dillman, D., Fu, R., & Brambrink, A. M. (2012) · Anesthesiology · doi:10.1097/aln.0b013e318246ea34 · Cited by 352
Self-citationKheterpal, S., Healy, D., Aziz, M. F., Shanks, A. M., Freundlich, R. E., Linton, F., Martin, L. D., Linton, J., Epps, J. L., Fernandez-Bustamante, A., et al. (2013) · Anesthesiology · doi:10.1097/aln.0000435832.39353.20 · Cited by 343
Self-citationThe difficult airway with recommendations for management – Part 2 – The anticipated difficult airway
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0020-x · Cited by 276
Kleine-Brueggeney, M., Greif, R., Schoettker, P., Savoldelli, G. L., Nabecker, S., & Theiler, L. G. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew058 · Cited by 216
Law, J. A., Duggan, L. V., Asselin, M., Baker, P., Crosby, E., Downey, A., Hung, O. R., Kovacs, G., Lemay, F., Noppens, R., et al. (2021) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-021-02008-z · Cited by 203
Videolaryngoscopy as a new standard of care
Zaouter, C., Calderon, J., & Hemmerling, T. M. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aeu266 · Cited by 185
Law, J. A., Duggan, L. V., Asselin, M., Baker, P., Crosby, E., Downey, A., Hung, O. R., Jones, P. M., Lemay, F., Noppens, R., et al. (2021) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-021-02007-0 · Cited by 184
Strategies for the prevention of airway complications – a narrative review
Cook, T. M. (2018) · Anaesthesia · doi:10.1111/anae.14123 · Cited by 167
Gu, Y., Robert, J., Kovacs, G., Milne, A. D., Morris, I., Hung, O., MacQuarrie, K., Mackinnon, S., & Adam Law, J. (2016) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-016-0654-6 · Cited by 57
Teoh, W. H., & Kristensen, M. S. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew148 · Cited by 21
Metadata
- Authors
- Aziz, M. F., Healy, D., Kheterpal, S., Fu, R. F., Dillman, D., & Brambrink, A. M.
- Venue
- Anesthesiology
- Published
- 2011-01-01
- Volume
- 114
- Issue
- 1
- Pages
- 34-41
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2102325787
- Cited by
- 395
- References
- 26
- FWCI
- 35.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.