The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Awake Fiberoptic or Awake Video Laryngoscopic Tracheal Intubation in Patients with Anticipated Difficult Airway Management: A Randomized Clinical Trial
Open accessAbstract
Background: Awake flexible fiberoptic intubation (FFI) is the gold standard for management of anticipated difficult tracheal intubation. The purpose of this study was to compare awake FFI to awake McGrath® video laryngoscope, (MVL), (Aircraft Medical, Edinburgh, Scotland, United Kingdom) intubation in patients with an anticipated difficult intubation. The authors examined the hypothesis that MVL intubation would be faster than FFI. Methods: Ninety-three adult patients with anticipated difficult intubation were randomly allocated to awake FFI or awake MVL, patients were given glycopyrrolate, nasal oxygen, topical lidocaine orally, and a transtracheal injection of 100 mg lidocaine. Remifentanil infusion was administered intravenously to a Ramsay sedation score of 2-4. Time to tracheal intubation was recorded by independent assessors. The authors also recorded intubation success on the first attempt, investigators' evaluation of ease of the technique, and patients reported intubation-discomfort evaluated on a visual analog scale. Results: Eighty-four patients were eligible for analysis. Time to tracheal intubation was median [interquartile range, IQR] 80 s [IQR 58-117] with FFI and 62 s [IQR 55-109] with MVL (P = 0.17). Intubation success on the first attempt was 79% versus 71% for FFI and MVL, respectively. The median visual analog scale score for ease of intubation was 2 (IQR 1-4) versus 1 (IQR 1-6) for FFI and MVL, respectively. The median visual analog scale score for patients' assessment of discomfort for both techniques was 2, FFI (IQR 0-3), MVL (IQR 0-4). Conclusions: The authors found no difference in time to tracheal intubation between awake FFI and awake MVL intubation performed by experienced anesthesiologists in patients with anticipated difficult airway.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlled Sedation with Alphaxalone-Alphadolone
Ramsay, M. A. E., Savege, T. M., Simpson, B. R. J., & Goodwin, R. (1974) · BMJ · doi:10.1136/bmj.2.5920.656 · Cited by 2,861
Updated by the Committee on Standards and Practice Parameters, Apfelbaum, J. L., Hagberg, C. A., Caplan, R. A., Blitt, C. D., Connis, R. T., Nickinovich, D. G., Hagberg, C. A., The previous update was developed by the American Society of Anesthesiologists Task Force on Difficult Airway Management, Caplan, R. A., et al. (2013) · Anesthesiology · doi:10.1097/aln.0b013e31827773b2 · Cited by 2,559
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415
Adverse Respiratory Events in Anesthesia: A Closed Claims Analysis
Caplan, R. A., Posner, K. L., Ward, R. J., & Cheney, F. W. (1990) · Anesthesiology · doi:10.1097/00000542-199005000-00010 · Cited by 1,060
Management of the Difficult Airway: A Closed Claims Analysis
Peterson, G. N., Domino, K. B., Caplan, R. A., Posner, K. L., Lee, L. A., & Cheney, F. W. (2005) · Anesthesiology · doi:10.1097/00000542-200507000-00009 · Cited by 852
Preoperative Airway Assessment: Predictive Value of a Multivariate Risk Index
El-Ganzouri, A. R., McCarthy, R. J., Tuman, K. J., Tanck, E. N., & Ivankovich, A. D. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199606000-00017 · Cited by 553
Lundstrøm, L. H., Møller, A. M., Rosenstock, C., Astrup, G., & Wetterslev, J. (2009) · Anesthesiology · doi:10.1097/aln.0b013e318194cac8 · Cited by 280
Self-citationEvaluation of the McGrath ® Series 5 videolaryngoscope after failed direct laryngoscopy*
Noppens, R. R., Möbus, S., Heid, F., Schmidtmann, I. M., Werner, C. D., & Piepho, T. (2010) · Anaesthesia · doi:10.1111/j.1365-2044.2010.06388.x · Cited by 132
A comparison of McGrath and Macintosh laryngoscopes in novice users: a manikin study
Ray, D. C., Billington, C. J., Kearns, P. K. A., Kirkbride, R., Mackintosh, K., Reeve, C. S., Robinson, N. J., Stewart, C. J., & Trudeau, T. (2009) · Anaesthesia · doi:10.1111/j.1365-2044.2009.06061.x · Cited by 117
Rosenstock, C. V., Møller, J., & Hauberg, A. (2001) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2001.450109.x · Cited by 79
Self-citation
Cited by
Apfelbaum, J. L., Hagberg, C. A., Connis, R. T., Abdelmalak, B. B., Agarkar, M., Dutton, R. P., Fiadjoe, J. E., Greif, R., Klock, P. A., Mercier, D., et al. (2022) · Anesthesiology · doi:10.1097/aln.0000000000004002 · Cited by 1,340
Difficult Airway Society guidelines for awake tracheal intubation (ATI) in adults
Ahmad, I., El‐Boghdadly, K., Bhagrath, R., Hodzovic, I., McNarry, A. F., Mir, F., O'Sullivan, E. P., Patel, A., Stacey, M., & Vaughan, D. (2020) · Anaesthesia · doi:10.1111/anae.14904 · Cited by 563
Apfelbaum, J. L., Hagberg, C. A., Connis, R. T., Abdelmalak, B., Agarkar, M., Dutton, R. P., Fiadjoe, J. E., Greif, R. T., Klock, P. A., Mercier, D. W., et al. (2022) · doi:10.48350/161339 · Cited by 526
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
Limitations of videolaryngoscopy
Norris, A., & Heidegger, T. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew122 · Cited by 38
Metadata
- Authors
- Rosenstock, C. V., Thøgersen, B., Afshari, A., Christensen, A.-L., Eriksen, C., & Gätke, M. R.
- Venue
- Anesthesiology
- Published
- 2012-06-01
- Volume
- 116
- Issue
- 6
- Pages
- 1210-1216
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2093544523
- Cited by
- 255
- References
- 12
- FWCI
- 26.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Awake Fiberoptic or Awake Video Laryngoscopic Tracheal Intubation in Patients with Anticipated Difficult Airway Management: A Randomized Clinical Trial. https://app.cochat.ai/papers/10.1097/aln.0b013e318254d085
- The paper
- Rosenstock, C. V., Thøgersen, B., Afshari, A., Christensen, A.-L., Eriksen, C., & Gätke, M. R. (2012). Awake Fiberoptic or Awake Video Laryngoscopic Tracheal Intubation in Patients with Anticipated Difficult Airway Management: A Randomized Clinical Trial. Anesthesiology. https://doi.org/10.1097/aln.0b013e318254d085
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.