CoChat

Clinical Impact of Sample Interference on Intensive Insulin Therapy in Severely Burned Patients: A Pilot Study

Open access
Tran, Nam K., Godwin, Zachary R., Bockhold, Jennifer C., Passerini, Anthony G., Cheng, Julian, Ingemason, Morgan · 2014 · Journal of Burn Care & Research
Cited by 21

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Severely burned patients benefit from intensive insulin therapy (IIT) for tight glycemic control (TGC). The authors evaluated the clinical impact of automatic correction of hematocrit and ascorbic acid interference for bedside glucose monitoring performance in critically ill burn patients. The performance of two point-of-care glucose monitoring systems (GMSs): 1) GMS1, an autocorrecting device, and 2) GMS2, a noncorrecting device were compared. Sixty remnant arterial blood samples were collected in a prospective observational study to evaluate hematocrit and ascorbic acid effects on GMS1 vs GMS2 accuracy paired against a plasma glucose reference. Next, we enrolled 12 patients in a pilot randomized controlled trial. Patients were randomized 1:1 to receive IIT targeting a TGC interval of 111 to 151 mg/dl and guided by either GMS1 or GMS2. GMS bias, mean insulin rate, and glycemic variability were calculated. In the prospective study, GMS1 results were similar to plasma glucose results (mean bias, -0.75 [4.0] mg/dl; n = 60; P = .214). GMS2 results significantly differed from paired plasma glucose results (mean bias, -5.66 [18.7] mg/dl; n = 60; P = .048). Ascorbic acid therapy elicited significant GMS2 performance bias (29.2 [27.2]; P < .001). Randomized controlled trial results reported lower mean bias (P < .001), glycemic variability (P < .05), mean insulin rate (P < .001), and frequency of hypoglycemia (P < .001) in the GMS1 group than in the GMS2 group. Anemia and high-dose ascorbic acid therapy negatively impact GMS accuracy and TGC in burn patients. Automatic correction of confounding factors improves glycemic control. Further studies are warranted to determine outcomes associated with accurate glucose monitoring during IIT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/bcr.0b013e31829b3700

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 21

Metadata

Authors
Tran, N. K., Godwin, Z. R., Bockhold, J. C., Passerini, A. G., Cheng, J., & Ingemason, M.
Venue
Journal of Burn Care & Research
Published
2014
Volume
35
Issue
1
Pages
72-79
ISSN
1559-047X (ISSN-L)
OpenAlex
W1972652808
Cited by
21
References
3
FWCI
2.36
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical Impact of Sample Interference on Intensive Insulin Therapy in Severely Burned Patients: A Pilot Study. https://app.cochat.ai/papers/10.1097/bcr.0b013e31829b3700
The paper
Tran, N. K., Godwin, Z. R., Bockhold, J. C., Passerini, A. G., Cheng, J., & Ingemason, M. (2014). Clinical Impact of Sample Interference on Intensive Insulin Therapy in Severely Burned Patients: A Pilot Study. Journal of Burn Care & Research. https://doi.org/10.1097/bcr.0b013e31829b3700

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.