The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Clinical Acceptance and Accuracy Assessment of Spinal Implants Guided With SpineAssist Surgical Robot: Retrospective Study
Abstract
STUDY DESIGN: Retrospective, multicenter study of robotically-guided spinal implant insertions. Clinical acceptance of the implants was assessed by intraoperative radiograph, and when available, postoperative computed tomography (CT) scans were used to determine placement accuracy. OBJECTIVE: To verify the clinical acceptance and accuracy of robotically-guided spinal implants and compare to those of unguided free-hand procedures. SUMMARY OF BACKGROUND DATA: SpineAssist surgical robot has been used to guide implants and guide-wires to predefined locations in the spine. SpineAssist which, to the best of the authors' knowledge, is currently the sole robot providing surgical assistance in positioning tools in the spine, guided over 840 cases in 14 hospitals, between June 2005 and June 2009. METHODS: Clinical acceptance of 3271 pedicle screws and guide-wires inserted in 635 reported cases was assessed by intraoperative fluoroscopy, where placement accuracy of 646 pedicle screws inserted in 139 patients was measured using postoperative CT scans. RESULTS: Screw placements were found to be clinically acceptable in 98% of the cases when intraoperatively assessed by fluoroscopic images. Measurements derived from postoperative CT scans demonstrated that 98.3% of the screws fell within the safe zone, where 89.3% were completely within the pedicle and 9% breached the pedicle by up to 2 mm. The remaining 1.4% of the screws breached between 2 and 4 mm, while only 2 screws (0.3%) deviated by more than 4 mm from the pedicle wall. Neurologic deficits were observed in 4 cases yet, following revisions, no permanent nerve damage was encountered, in contrast to the 0.6% to 5% of neurologic damage reported in the literature. CONCLUSION: SpineAssist offers enhanced performance in spinal surgery when compared to free-hand surgeries, by increasing placement accuracy and reducing neurologic risks. In addition, 49% of the cases reported herein used a percutaneous approach, highlighting the contribution of SpineAssist in procedures without anatomic landmarks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accuracy of Pedicular Screw Placement In Vivo
GERTZBEIN, S. D., & ROBBINS, S. E. (1990) · Spine · doi:10.1097/00007632-199001000-00004 · Cited by 1,381
Schwender, J. D., Holly, L. T., Rouben, D. P., & Foley, K. T. (2005) · Journal of Spinal Disorders & Techniques · doi:10.1097/01.bsd.0000132291.50455.d0 · Cited by 561
Complications Associated with Pedicle Screws*
LONSTEIN, J. E., DENIS, F., PERRA, J. H., PINTO, M. R., SMITH, M. D., & WINTER, R. B. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199911000-00003 · Cited by 542
Amiot, L.-P., Lang, K., Putzier, M., Zippel, H., & Labelle, H. (2000) · Spine · doi:10.1097/00007632-200003010-00012 · Cited by 450
Bone-mounted miniature robot for surgical procedures: concept and clinical applications
Shoham, M., Burman, M., Zehavi, E., Joskowicz, L., Batkilin, E., & Kunicher, Y. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817075 · Cited by 292
Self-citationComplications of Lumbar Spinal Fusion with Transpedicular Instrumentation
Davne, S. H., & Myers, D. L. (1992) · Spine · doi:10.1097/00007632-199206001-00021 · Cited by 248
Clinical Accuracy of Fluoroscopic Computer-Assisted Pedicle Screw Fixation: A CT Analysis
Rampersaud, Y. R., Pik, J. H. T., Salonen, D., & Farooq, S. (2005) · Spine · doi:10.1097/01.brs.0000157490.65706.38 · Cited by 160
Robotic assisted spinal surgery-from concept to clinical practice
Shoham, M., Lieberman, I. H., Benzel, E. C., Togawa, D., Zehavi, E., Zilberstein, B., ROFFMAN, M., Bruskin, A., Fridlander, A., Joskowicz, L., et al. (2007) · Computer Aided Surgery · doi:10.3109/10929080701243981 · Cited by 113
Self-citationMorphological Study of the Spinal Canal Content for Subarachnoid Endoscopy
Zaaroor, M., Kósa, G., Peri-Eran, A., Maharil, I., Shoham, M., & Goldsher, D. (2006) · min - Minimally Invasive Neurosurgery · doi:10.1055/s-2006-948000 · Cited by 35
Self-citation
Cited by
Medical Robotics and Computer-Integrated Surgery
Taylor, R. H., Menciassi, A., Fichtinger, G., Fiorini, P., & Dario, P. (2016) · Springer Handbooks · doi:10.1007/978-3-319-32552-1_63 · Cited by 325
Technique, Results, and Complications Related to Robot-Assisted Stereoelectroencephalography
González-Martínez, J., Bulacio, J., Thompson, S., Gale, J., Smithason, S., Najm, I., & Bingaman, W. (2016) · Neurosurgery · doi:10.1227/neu.0000000000001034 · Cited by 315
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Hyun, S.-J., Kim, K.-J., Jahng, T.-A., & Kim, H.-J. (2017) · Spine · doi:10.1097/brs.0000000000001778 · Cited by 305
Gautschi, O. P., Schatlo, B., Schaller, K., & Tessitore, E. (2011) · Neurosurgical Focus · doi:10.3171/2011.7.focus11168 · Cited by 268
Metadata
- Authors
- Devito, D. P., Kaplan, L., Dietl, R., Pfeiffer, M., Horne, D., Silberstein, B., Hardenbrook, M., Kiriyanthan, G., Barzilay, Y., Bruskin, A., Sackerer, D., Alexandrovsky, V., Stüer, C., Burger, R., Maeurer, J., Gordon, D. G., Schoenmayr, R., Friedlander, A., Knoller, N., Schmieder, K., Pechlivanis, I., Kim, I.-S., Meyer, B., & Shoham, M.
- Venue
- Spine
- Published
- 2010-11
- Volume
- 35
- Issue
- 24
- Pages
- 2109-2115
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2088839360
- Cited by
- 407
- References
- 9
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.