Role of Strain Rate in the Pathogenesis of Ventilator-Induced Lung Edema*
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Objective: Lungs behave as viscoelastic polymers. Harms of mechanical ventilation could then depend on not only amplitude (strain) but also velocity (strain rate) of lung deformation. Herein, we tested this hypothesis. Design: Laboratory investigation. Setting: Animal unit. Subjects: Thirty healthy piglets. Interventions: Two groups of animals were ventilated for 54 hours with matched lung strains (ratio between tidal volume and functional residual capacity) but different lung strain rates (ratio between strain and inspiratory time). Individual strains ranged between 0.6 and 3.5 in both groups. Piglets ventilated with low strain rates had an inspiratory-to-expiratory time ratio of 1:2–1:3. Those ventilated with high strain rates had much lower inspiratory-to-expiratory time ratios (down to 1:9). Respiratory rate was always 15 breaths/min. Lung viscoelastic behavior, with ventilator setting required per protocol, was “quantified” as dynamic respiratory system hysteresis (pressure-volume loop [in Joules]) and stress relaxation (airway pressure drop during an end-inspiratory pause [in cm H 2 O]). Primary outcome was the occurrence of pulmonary edema within 54 hours. Measurements and Main Results: On average, the two study groups were ventilated with well-matched strains (2.1 ± 0.9 vs 2.1 ± 0.9; p = 0.864) but different strain rates (1.8 ± 0.8 vs 4.6 ± 1.5 s–1; p < 0.001), dynamic respiratory system hysteresis (0.6 ± 0.3 vs 1.4 ± 0.8 J; p = 0.001), and stress relaxation (3.1 ± 0.9 vs 5.0 ± 2.3 cm H 2 O; p = 0.008). The prevalence of pulmonary edema was 20% among piglets ventilated with low strain rates and 73% among those ventilated with high strain rates (p = 0.010). Conclusions: High strain rate is a risk factor for ventilator-induced pulmonary edema, possibly because it amplifies lung viscoelastic behavior.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
Driving pressure and survival in the acute respiratory distress syndrome.
Amato, M. B. P., Meade, M. O., Slutsky, A. S., Brochard, L., Costa, E. L. V., Schoenfeld, D. A., Stewart, T. E., Briel, M., Talmor, D., Mercat, A., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmsa1410639 · Cited by 2,801 · cited 1×
“Current guidelines for “safe” mechanical ventilation in humans with acute respiratory failure recommend limiting tidal volume, plateau (end-inspiratory pause), and possibly even driving (endinspiratory pause minus end-expiratory pause) airway pressure (37, 38).”
BackgroundVentilator-induced Lung Injury: Lessons from Experimental Studies
DREYFUSS, D., & SAUMON, G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.9604014 · Cited by 2,297 · cited 1×
“However, it can also worsen, or even cause, pulmonary damage (1, 2).”
BackgroundVentilator-Induced Lung Injury
Slutsky, A. S., & Ranieri, V. M. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208707 · Cited by 2,211
Stress distribution in lungs: a model of pulmonary elasticity.
Mead, J., Takishima, T., & Leith, D. (1970) · Journal of Applied Physiology · doi:10.1152/jappl.1970.28.5.596 · Cited by 1,410
Mechanical Factors in Distribution of Pulmonary Ventilation
Otis, A. B., McKerrow, C. B., Bartlett, R. A., Mead, J., McIlroy, M. B., Selverstone, N. J., & Radford, E. P. (1956) · Journal of Applied Physiology · doi:10.1152/jappl.1956.8.4.427 · Cited by 1,015 · cited 2×
“Alveolar units differ for mechanical properties: those with short time constants inflate rapidly, and therefore receive most of tidal volume, whereas those with long time constants do so with some delay (30).”
BackgroundGattinoni, L., & Pesenti, A. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2627-z · Cited by 837 · cited 1×
“org e843 unpredictable manner (the “baby” lung concept) (18).”
BackgroundSelf-citationLung Stress and Strain during Mechanical Ventilation for Acute Respiratory Distress Syndrome
Chiumello, D., Carlesso, E., Cadringher, P., Caironi, P., Valenza, F., Polli, F., Tallarini, F., Cozzi, P., Cressoni, M., Colombo, A., et al. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200710-1589oc · Cited by 777 · cited 1×
“This is probably not true for tidal volume (19) and gas flow.”
BackgroundSelf-citationLung Inhomogeneity in Patients with Acute Respiratory Distress Syndrome
Cressoni, M., Cadringher, P., Chiurazzi, C., Amini, M., Gallazzi, E., Marino, A., Brioni, M., Carlesso, E., Chiumello, D., Quintel, M., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201308-1567oc · Cited by 352
Self-citationLung Stress and Strain during Mechanical Ventilation: Any Safe Threshold?
Protti, A., Cressoni, M., Santini, A., Langer, T., Mietto, C., Febres, D., Chierichetti, M., Coppola, S., Conte, G., Gatti, S., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201010-1757oc · Cited by 346 · cited 1×
“0 usually develop fatal pulmonary edema (7).”
Self-citation
Cited by
Ventilator-related causes of lung injury: the mechanical power
Gattinoni, L., Tonetti, T., Cressoni, M., Cadringher, P., Herrmann, P., Moerer, O., Protti, A., Gotti, M., Chiurazzi, C., Carlesso, E., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4505-2 · Cited by 1,055
Self-citationMarini, J. J., Rocco, P. R. M., & Gattinoni, L. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201908-1545ci · Cited by 297
Self-citationThe future of mechanical ventilation: lessons from the present and the past
Gattinoni, L., Marini, J. J., Collino, F., Maiolo, G., Rapetti, F., Tonetti, T., Vasques, F., & Quintel, M. (2017) · Critical Care · doi:10.1186/s13054-017-1750-x · Cited by 279
Self-citationDriving pressure and mechanical power: new targets for VILI prevention
Tonetti, T., Vasques, F., Rapetti, F., Maiolo, G., Collino, F., Romitti, F., Camporota, L., Cressoni, M., Cadringher, P., Quintel, M., et al. (2017) · Annals of Translational Medicine · doi:10.21037/atm.2017.07.08 · Cited by 258
Self-citationAirway driving pressure and lung stress in ARDS patients
Chiumello, D., Carlesso, E., Brioni, M., & Cressoni, M. (2016) · Critical Care · doi:10.1186/s13054-016-1446-7 · Cited by 213
F ifty Y ears of R esearch in ARDS.Respiratory Mechanics in Acute Respiratory Distress Syndrome
Henderson, W. R., Chen, L., Amato, M. B. P., & Brochard, L. J. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201612-2495ci · Cited by 196
“This peak Palv, however, has been directly linked to VILI (55), representing the effective pressure imposed by the ventilator against the respiratory system, being opposed by the elastic tension generated across the alveolar walls and thoracic structures.”
BackgroundChiumello, D., Gotti, M., Guanziroli, M., Formenti, P., Umbrello, M., Pasticci, I., Mistraletti, G., & Busana, M. (2020) · Critical Care · doi:10.1186/s13054-020-03116-w · Cited by 177
“While it can be reasonably assumed that the energy dissipated in the airways and the endotracheal tube does not cause VILI, the one dissipated to perform the tissue strain has been already shown to cause damage and should not be ignored [23].”
BackgroundMechanical power at a glance: a simple surrogate for volume-controlled ventilation
Giosa, L., Busana, M., Pasticci, I., Bonifazi, M., Macrì, M. M., Romitti, F., Vassalli, F., Chiumello, D., Quintel, M., Marini, J. J., et al. (2019) · Intensive Care Medicine Experimental · doi:10.1186/s40635-019-0276-8 · Cited by 166
Self-citationNieman, G. F., Satalin, J., Andrews, P., Aiash, H., Habashi, N. M., & Gatto, L. A. (2017) · Intensive Care Medicine Experimental · doi:10.1186/s40635-017-0121-x · Cited by 143
Metadata
- Authors
- Protti, A., Maraffi, T., Milesi, M., Votta, E., Santini, A., Pugni, P., Andreis, D. T., Nicosia, F., Zannin, E., Gatti, S., Vaira, V., Ferrero, S., & Gattinoni, L.
- Venue
- Critical Care Medicine
- Published
- 2016-09
- Volume
- 44
- Issue
- 9
- Pages
- e838-e845
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2340189633
- Cited by
- 162
- References
- 28
- FWCI
- 14.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.