Near-Continuous Glucose Monitoring Makes Glycemic Control Safer in ICU Patients*
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Objectives: Tight glycemic control using intermittent blood glucose measurements is associated with a risk of hypoglycemia. Glucose concentrations can now be measured near continuously (every 5–15 min). We assessed the quality and safety of glycemic control guided by a near-continuous glucose monitoring system in ICU patients. Design: Prospective, cluster-randomized, crossover study. Setting: Thirty-five–bed medico-surgical department of intensive care with four separate ICUs. Patients: Adult patients admitted to the department and expected to stay for at least 3 days were considered for inclusion if they had persistent hyperglycemia (blood glucose > 150 mg/dL) up to 6 hours after admission and/or were receiving insulin therapy. Interventions: A peripheral venous catheter was inserted in all patients and connected to a continuous glucose monitoring sensor (GlucoClear; Edwards Lifesciences, Irvine, CA). The four ICUs were randomized in pairs in a crossover design to glycemic control using unblinded or blinded continuous glucose monitoring monitors. The insulin infusion rate was adjusted to keep blood glucose between 90 and 150 mg/dL using the blood glucose values displayed on the continuous glucose monitor (continuous glucose monitoring group—unblinded units) or according to intermittent blood glucose readings (intermittent glucose monitoring group—blinded units). Measurements and Main Results: The quality and safety of glycemic control were assessed using the proportion of time in range, the frequency of blood glucose less than 70 mg/dL, and the time spent with blood glucose less than 70 mg/dL (TB70), using blood glucose values measured by the continuous glucose monitoring device. Seventy-seven patients were enrolled: 39 in the continuous glucose monitoring group and 38 in the intermittent glucose monitoring group. A total of 43,107 blood glucose values were recorded. The time in range was similar in the two groups. The incidence of hypoglycemia (8/39 [20.5%] vs 15/38 [39.5%]) and the TB70 (0.4% ± 0.9% vs 1.6% ± 3.4%; p < 0.05) was lower in the continuous glucose monitoring than in the intermittent glucose monitoring group. Conclusions: Use of a continuous glucose monitoring–based strategy decreased the incidence and severity of hypoglycemia, thus improving the safety of glycemic control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moghissi, E. S., Korytkowski, M. T., DiNardo, M., Einhorn, D., Hellman, R., Hirsch, I. B., Inzucchi, S. E., Ismail-Beigi, F., Kirkman, M. S., & Umpierrez, G. E. (2009) · Diabetes Care · doi:10.2337/dc09-9029 · Cited by 1,444
Hypoglycemia and risk of death in critically ill patients
The NICE-SUGAR Study Investigators (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1204942 · Cited by 1,009
Hyperglycemia-related mortality in critically ill patients varies with admission diagnosis
Falciglia, M., Freyberg, R. W., Almenoff, P. L., D’Alessio, D. A., & Render, M. L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b083f7 · Cited by 576
Toward Understanding Tight Glycemic Control in the ICU
Marik, P. E., & Preiser, J.-C. (2010) · Chest · doi:10.1378/chest.09-1737 · Cited by 365
Self-citationAssociation between intensive care unit-acquired dysglycemia and in-hospital mortality.
Badawi, O., Waite, M. D., Fuhrman, S. A., & Zuckerman, I. H. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182656ae5 · Cited by 142
International recommendations for glucose control in adult non diabetic critically ill patients
Ichai, C., Preiser, J.-C., (SFAR), F. T. S. F. D.-R., & Société de Réanimation de langue Française (SRLF) and the Experts group (2010) · Critical Care · doi:10.1186/cc9258 · Cited by 127
Self-citationIntensive versus intermediate glucose control in surgical intensive care unit patients
Okabayashi, T., Shima, Y., Sumiyoshi, T., Kozuki, A., Tokumaru, T., Iiyama, T., Sugimoto, T., Kobayashi, M., Yokoyama, M., & Hanazaki, K. (2014) · Diabetes Care · doi:10.2337/dc13-1771 · Cited by 119
Schultz, M. J., Harmsen, R. E., & Spronk, P. E. (2010) · Critical Care · doi:10.1186/cc8966 · Cited by 53
Zhang, R., Isakow, W., Kollef, M. H., & Scott, M. G. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002572 · Cited by 25
Cited by
Gunst, J., De Bruyn, A., & Van den Berghe, G. (2019) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000000706 · Cited by 84
Cook, D. J., Rutherford, W. B., Scales, D. C., Adhikari, N. K. J., & Cuthbertson, B. H. (2021) · Critical Care Medicine · doi:10.1097/ccm.0000000000004885 · Cited by 14
Giovannetti, E. R., Lee, R. O., Thomas, R. L., Wolinsky, T., Talbot, A. V., Ali, R. S., Cavaiola, T. S., Kulasa, K., & Boeder, S. C. (2025) · Endocrine Practice · doi:10.1016/j.eprac.2025.05.751 · Cited by 7
Metadata
- Authors
- Preiser, J.-C., Lheureux, O., Thooft, A., Brimioulle, S., Goldstein, J., & Vincent, J.-L.
- Venue
- Critical Care Medicine
- Published
- 2018-08
- Volume
- 46
- Issue
- 8
- Pages
- 1224-1229
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2799970170
- Cited by
- 67
- References
- 9
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-Continuous Glucose Monitoring Makes Glycemic Control Safer in ICU Patients*. https://app.cochat.ai/papers/10.1097/ccm.0000000000003157
- The paper
- Preiser, J.-C., Lheureux, O., Thooft, A., Brimioulle, S., Goldstein, J., & Vincent, J.-L. (2018). Near-Continuous Glucose Monitoring Makes Glycemic Control Safer in ICU Patients*. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000003157
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.