The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
National Performance on the Medicare SEP-1 Sepsis Quality Measure
Open accessAbstract
Objectives: The Centers for Medicare and Medicaid Services requires hospitals to report compliance with a sepsis treatment bundle as part of its Inpatient Quality Reporting Program. We used recently released data from this program to characterize national performance on the sepsis measure, known as SEP-1. Design: Cross-sectional study of United States hospitals participating in the Centers for Medicare and Medicaid Services Hospital Inpatient Quality Reporting Program linked to Centers for Medicare and Medicaid Services’ Healthcare Cost Reporting Information System. Setting: General, short-stay, acute-care hospitals in the United States. Measurements and Main Results: We examined the hospital factors associated with reporting SEP-1 data, the hospital factors associated with performance on the SEP-1 measure, and the relationship between SEP-1 performance and performance on other quality measures related to time-sensitive medical conditions. A total of 3,283 hospitals were eligible for the analysis, of which 2,851 (86.8%) reported SEP-1 performance data. SEP-1 reporting was more common in larger, nonprofit hospitals. The most common reason for nonreporting was an inadequate case volume. Among hospitals reporting SEP-1 performance data, overall bundle compliance was generally low, but it varied widely across hospitals (mean and sd : 48.9% ± 19.4%). Compared with hospitals with worse SEP-1 performance, hospitals with better SEP-1 performance tended to be smaller, for-profit, nonteaching, and with intermediate-sized ICUs. Better hospital performance on SEP-1 was associated with higher rates of timely head CT interpretation for stroke patients (rho = 0.16; p < 0.001), more frequent aspirin administration for patients with chest pain or heart attacks (rho = 0.24; p < 0.001) and shorter median time to electrocardiogram for patients with chest pain (rho = –0.12; p < 0.001). Conclusions: The majority of eligible hospitals reported SEP-1 data, and overall bundle compliance was highly variable. SEP-1 performance was associated with structural hospital characteristics and performance on other measures of hospital quality, providing preliminary support for SEP-1 performance as a marker of timely hospital sepsis care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“National SEP-1 performance has remained modest and heterogeneous since implementation. Mean hospital compliance is approximately 49%, with wide interhospital variability [15].”
From Artificial Intelligence to Facilitate SEP-1 Measure Compliance and Fluid Management in Sepsis (2026) · cites this paper as [15]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“However, individual elements can vary in feasibility obscuring true performance [15,16].”
From Artificial Intelligence to Facilitate SEP-1 Measure Compliance and Fluid Management in Sepsis (2026) · cites this paper as [15]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While some studies associate compliance with improved outcomes, measurement variability and limited evidence for certain mandated elements remain central concerns [7,8,15,19].”
From Artificial Intelligence to Facilitate SEP-1 Measure Compliance and Fluid Management in Sepsis (2026) · cites this paper as [15]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Despite consensus that sepsis treatment bundles improve patient outcomes, only 49% of patients in US hospitals receive appropriate care [14].”
From Integrating a Machine Learning System Into Clinical Workflows: Qualitative Study (2020) · cites this paper as [14]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“National SEP-1 performance remains modest and variably measured.”
From Artificial Intelligence to Facilitate SEP-1 Measure Compliance and Fluid Management in Sepsis (2026) · cites this paper as [15]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessing construct validity in organizational research
Bagozzi, R. P., Yi, Y., & Phillips, L. W. (1991) · Administrative Science Quarterly · doi:10.2307/2393203 · Cited by 6,621
Time to treatment and mortality during mandated emergency care for sepsis.
Seymour, C. W., Gesten, F., Prescott, H. C., Friedrich, M. E., Iwashyna, T. J., Phillips, G. S., Lemeshow, S., Osborn, T., Terry, K. M., & Levy, M. M. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1703058 · Cited by 2,225
Incidence and trends of sepsis in US hospitals using clinical vs claims data, 2009-2014.
Rhee, C., Dantes, R., Epstein, L., Murphy, D. J., Seymour, C. W., Iwashyna, T. J., Kadri, S. S., Angus, D. C., Danner, R. L., Fiore, A. E., et al. (2017) · JAMA · doi:10.1001/jama.2017.13836 · Cited by 1,884
The timing of early antibiotics and hospital mortality in sepsis.
Liu, V. X., Fielding-Singh, V., Greene, J. D., Baker, J. M., Iwashyna, T. J., Bhattacharya, J., & Escobar, G. J. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201609-1848oc · Cited by 1,006
Hospital Deaths in Patients With Sepsis From 2 Independent Cohorts
Liu, V., Escobar, G. J., Greene, J. D., Soule, J., Whippy, A., Angus, D. C., & Iwashyna, T. J. (2014) · JAMA · doi:10.1001/jama.2014.5804 · Cited by 977
Levy, M. M., Dellinger, R. P., Townsend, S. R., Linde-Zwirble, W. T., Marshall, J. C., Bion, J., Schorr, C., Artigas, A., Ramsay, G., Beale, R., et al. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181cb0cdc · Cited by 950
Ferrer, R. (2008) · JAMA · doi:10.1001/jama.299.19.2294 · Cited by 741
Early, Goal-Directed Therapy for Septic Shock — A Patient-Level Meta-Analysis
The PRISM Investigators (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1701380 · Cited by 600
Fonarow, G. C., Smith, E. E., Saver, J. L., Reeves, M. J., Bhatt, D. L., Grau-Sepulveda, M. V., Olson, D. M., Hernandez, A. F., Peterson, E. D., & Schwamm, L. H. (2011) · Circulation · doi:10.1161/circulationaha.110.974675 · Cited by 579
Surviving Sepsis Campaign: Association Between Performance Metrics and Outcomes in a 7.5-Year Study
Levy, M. M., Rhodes, A., Phillips, G. S., Townsend, S. R., Schorr, C. A., Beale, R., Osborn, T., Lemeshow, S., Chiche, J.-D., Artigas, A., et al. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000000723 · Cited by 566
Research works printed but not linked: 1
- Rhee, 2018, Compliance with the national SEP-1 quality measure and association with sepsis outcomes., Crit Care Med, 1
Cited by
Fluid Therapy for Critically Ill Adults With Sepsis: A Review
Zampieri, F. G., Bagshaw, S. M., & Semler, M. W. (2023) · JAMA · doi:10.1001/jama.2023.7560 · Cited by 184
Integrating a Machine Learning System Into Clinical Workflows: Qualitative Study
Sandhu, S., Lin, A. L., Brajer, N., Sperling, J., Ratliff, W., Bedoya, A. D., Balu, S., O'Brien, C., & Sendak, M. P. (2020) · Journal of Medical Internet Research · doi:10.2196/22421 · Cited by 168
Sivaraman, V., Bukowski, L. A., Levin, J., Kahn, J. M., & Perer, A. (2023) · Proceedings of the 2023 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3544548.3581075 · Cited by 141
Self-citationYealy, D. M., Mohr, N. M., Shapiro, N. I., Venkatesh, A. K., Jones, A. E., & Self, W. H. (2021) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2021.02.006 · Cited by 136
Evaluation of hospital nurse-to-patient staffing ratios and sepsis bundles on patient outcomes
Lasater, K. B., Sloane, D. M., McHugh, M. D., Cimiotti, J. P., Connell, K. A., Martin, B., Alexander, M., & Aiken, L. H. (2020) · American Journal of Infection Control · doi:10.1016/j.ajic.2020.12.002 · Cited by 99
Metadata
- Authors
- Barbash, I. J., Davis, B., & Kahn, J. M.
- Affiliations
- University of Pittsburgh (US)
- Venue
- Critical Care Medicine
- Published
- 2019-08
- Volume
- 47
- Issue
- 8
- Pages
- 1026-1032
- ISSN
- 0090-3493 (ISSN-L)
- PMC
- PMC6588513
- OpenAlex
- W2908328259
- Cited by
- 86
- References
- 29
- Citations by year
- 2026: 12 · 2025: 9 · 2024: 8 · 2023: 11 · 2022: 11 · 2021: 15 · 2020: 14 · 2019: 6
- FWCI
- 8.75
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Agency for Healthcare Research and Quality (K08 HS025455)
- National Heart, Lung, and Blood Institute (K24HL133444)
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Quality and Management
- Social Sciences › Economics, Econometrics and Finance › Economics and Econometrics › Healthcare Policy and Management
- Keywords
- sepsis, hospital quality reporting, bundle compliance, hospital characteristics, patient volume, chest pain, electrocardiogram
- MeSH terms
- Cross-Sectional Studies, Emergency Service, Hospital, Female, Humans, Male, Shock, Septic, United States, Sepsis, Quality Indicators, Health Care, Patient Care Bundles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: National Performance on the Medicare SEP-1 Sepsis Quality Measure. https://app.cochat.ai/papers/10.1097/ccm.0000000000003613
- The paper
- Barbash, I. J., Davis, B., & Kahn, J. M. (2019). National Performance on the Medicare SEP-1 Sepsis Quality Measure. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000003613
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.