Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 206

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Intensive care unit alarms—How many do we need?*

Siebig, Sylvia, Kuhls, Silvia, Imhoff, Michael, Gather, Ursula, Schölmerich, Jürgen, Wrede, Christian E.·2010·Critical Care Medicine

Abstract

OBJECTIVE: To validate cardiovascular alarms in critically ill patients in an experimental setting by generating a database of physiologic data and clinical alarm annotations, and report the current rate of alarms and their clinical validity. Currently, monitoring of physiologic parameters in critically ill patients is performed by alarm systems with high sensitivity, but low specificity. As a consequence, a multitude of alarms with potentially negative impact on the quality of care is generated. DESIGN: Prospective, observational, clinical study. SETTING: Medical intensive care unit of a university hospital. DATA SOURCE: Data from different medical intensive care unit patients were collected between January 2006 and May 2007. MEASUREMENTS AND MAIN RESULTS: Physiologic data at 1-sec intervals, monitor alarms, and alarm settings were extracted from the surveillance network. Video recordings were annotated with respect to alarm relevance and technical validity by an experienced physician. During 982 hrs of observation, 5934 alarms were annotated, corresponding to six alarms per hour. About 40% of all alarms did not correctly describe the patient condition and were classified as technically false; 68% of those were caused by manipulation. Only 885 (15%) of all alarms were considered clinically relevant. Most of the generated alarms were threshold alarms (70%) and were related to arterial blood pressure (45%). CONCLUSION: This study used a new approach of off-line, video-based physician annotations, showing that even with modern monitoring systems most alarms are not clinically relevant. As the majority of alarms are simple threshold alarms, statistical methods may be suitable to help reduce the number of false-positive alarms. Our study is also intended to develop a reference database of annotated monitoring alarms for further application to alarm algorithm research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181cb0888

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 12

  1. Chambrin, 2001, Crit Care, 5, 184, 10.1186/cc1021 · DOI
  2. Balogh, 1993, Intensive Care Med, 19, 343, 10.1007/BF01694709 · DOI
  3. Bliss, 1995, Ergonomics, 38, 2300, 10.1080/00140139508925269 · DOI · Paper page
  4. Pugh, 2007, Care Crit Ill, 23, 105
  5. Koski, 1990, Int J Clin Monit Comput, 7, 129, 10.1007/BF01724206 · DOI
  6. Tsien, 1997, Crit Care Med, 25, 614, 10.1097/00003246-199704000-00010 · DOI · Paper page
  7. Cropp, 1994, Chest, 105, 1217, 10.1378/chest.105.4.1217 · DOI
  8. Aaron, 1996, Sleep, 19, 707, 10.1093/sleep/19.9.707 · DOI · Paper page
  9. Cooper, 2000, Chest, 117, 809, 10.1378/chest.117.3.809 · DOI · Paper page
  10. Imhoff, 2006, Anesth Analg, 102, 1525, 10.1213/01.ane.0000204385.01983.61 · DOI · Paper page
  11. Siebig, 2009, Anästhesist, 58, 240, 10.1007/s00101-008-1487-7 · DOI
  12. Siebig, 2009, Anaesth Intensive Care, 37, 112, 10.1177/0310057X0903700116 · DOI

Cited by

See all 206

Metadata

Authors
Siebig, S., Kuhls, S., Imhoff, M., Gather, U., Schölmerich, J., & Wrede, C. E.
Venue
Critical Care Medicine
Published
2010-02
Volume
38
Issue
2
Pages
451-456
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2009398155
Cited by
206
References
2
FWCI
14.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intensive care unit alarms—How many do we need?*. https://app.cochat.ai/papers/10.1097/ccm.0b013e3181cb0888
The paper
Siebig, S., Kuhls, S., Imhoff, M., Gather, U., Schölmerich, J., & Wrede, C. E. (2010). Intensive care unit alarms—How many do we need?*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3181cb0888

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.