The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Intensive care unit alarms—How many do we need?*
Abstract
OBJECTIVE: To validate cardiovascular alarms in critically ill patients in an experimental setting by generating a database of physiologic data and clinical alarm annotations, and report the current rate of alarms and their clinical validity. Currently, monitoring of physiologic parameters in critically ill patients is performed by alarm systems with high sensitivity, but low specificity. As a consequence, a multitude of alarms with potentially negative impact on the quality of care is generated. DESIGN: Prospective, observational, clinical study. SETTING: Medical intensive care unit of a university hospital. DATA SOURCE: Data from different medical intensive care unit patients were collected between January 2006 and May 2007. MEASUREMENTS AND MAIN RESULTS: Physiologic data at 1-sec intervals, monitor alarms, and alarm settings were extracted from the surveillance network. Video recordings were annotated with respect to alarm relevance and technical validity by an experienced physician. During 982 hrs of observation, 5934 alarms were annotated, corresponding to six alarms per hour. About 40% of all alarms did not correctly describe the patient condition and were classified as technically false; 68% of those were caused by manipulation. Only 885 (15%) of all alarms were considered clinically relevant. Most of the generated alarms were threshold alarms (70%) and were related to arterial blood pressure (45%). CONCLUSION: This study used a new approach of off-line, video-based physician annotations, showing that even with modern monitoring systems most alarms are not clinically relevant. As the majority of alarms are simple threshold alarms, statistical methods may be suitable to help reduce the number of false-positive alarms. Our study is also intended to develop a reference database of annotated monitoring alarms for further application to alarm algorithm research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lawless (1994) · doi:10.1097/00003246-199406000-00017 · Cited by 406
Chambrin, M.-C., Ravaux, P., Calvelo-Aros, D., Jaborska, A., Chopin, C., & Boniface, B. (1999) · Intensive Care Medicine · doi:10.1007/s001340051082 · Cited by 227
Research works printed but not linked: 12
- Chambrin, 2001, Crit Care, 5, 184, 10.1186/cc1021 · DOI
- Balogh, 1993, Intensive Care Med, 19, 343, 10.1007/BF01694709 · DOI
- Bliss, 1995, Ergonomics, 38, 2300, 10.1080/00140139508925269 · DOI · Paper page
- Pugh, 2007, Care Crit Ill, 23, 105
- Koski, 1990, Int J Clin Monit Comput, 7, 129, 10.1007/BF01724206 · DOI
- Tsien, 1997, Crit Care Med, 25, 614, 10.1097/00003246-199704000-00010 · DOI · Paper page
- Cropp, 1994, Chest, 105, 1217, 10.1378/chest.105.4.1217 · DOI
- Aaron, 1996, Sleep, 19, 707, 10.1093/sleep/19.9.707 · DOI · Paper page
- Cooper, 2000, Chest, 117, 809, 10.1378/chest.117.3.809 · DOI · Paper page
- Imhoff, 2006, Anesth Analg, 102, 1525, 10.1213/01.ane.0000204385.01983.61 · DOI · Paper page
- Siebig, 2009, Anästhesist, 58, 240, 10.1007/s00101-008-1487-7 · DOI
- Siebig, 2009, Anaesth Intensive Care, 37, 112, 10.1177/0310057X0903700116 · DOI
Cited by
Monitor Alarm Fatigue : An Integrative Review
Cvach, M. (2012) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-46.4.268 · Cited by 632
Sendelbach, S., & Funk, M. (2013) · AACN Advanced Critical Care · doi:10.4037/nci.0b013e3182a903f9 · Cited by 497
Drew, B. J., Harris, P., Zègre-Hemsey, J. K., Mammone, T., Schindler, D., Salas-Boni, R., Bai, Y., Tinoco, A., Ding, Q., & Hu, X. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110274 · Cited by 438
Challenges and Research Directions in Medical Cyber–Physical Systems
Lee, I., Sokolsky, O., Chen, S., Hatcliff, J., Jee, E., Kim, B., King, A., Mullen-Fortino, M., Park, S., Roederer, A., et al. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165270 · Cited by 373
Sandau, K. E., Funk, M., Auerbach, A., Barsness, G. W., Blum, K., Cvach, M., Lampert, R., May, J. L., McDaniel, G. M., Perez, M. V., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000527 · Cited by 342
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
Paine, C. W., Goel, V. V., Ely, E., Stave, C. D., Stemler, S., Zander, M., & Bonafide, C. P. (2016) · Journal of Hospital Medicine · doi:10.1002/jhm.2520 · Cited by 183
“Finally, though not necessarily a limitation, several studies were conducted by authors involved in or funded by the medical device industry.(11,15,19,31,32) This has the potential to introduce bias, although we have no indication that the quality of the science was adversely impacted.”
BackgroundMethodMakam, A. N., Nguyen, O. K., & Auerbach, A. D. (2015) · Journal of Hospital Medicine · doi:10.1002/jhm.2347 · Cited by 99
Sowan, A. K., Gomez, T. M., Tarriela, A. F., Reed, C. C., & Paper, B. M. (2016) · JMIR Human Factors · doi:10.2196/humanfactors.5098 · Cited by 83
“Alarm safety is a priority in intensive care units (ICUs) where alarm rates are known to be the highest [7,8].”
Sowan, A. K., Tarriela, A. F., Gomez, T. M., Reed, C. C., & Rapp, K. M. (2015) · JMIR Human Factors · doi:10.2196/humanfactors.4196 · Cited by 79
“It is worth noting that the combined samples of 2005-2006 and 2011 HTF clinical alarms surveys were from more than ten different hospital departments, including the intensive care units (ICUs).”
BackgroundInfluentialStop the Noise: A Quality Improvement Project to Decrease Electrocardiographic Nuisance Alarms
Sendelbach, S., Wahl, S., Anthony, A., & Shotts, P. (2015) · Critical Care Nurse · doi:10.4037/ccn2015858 · Cited by 64
Reduction of false arrhythmia alarms using signal selection and machine learning
Eerikäinen, L. M., Vanschoren, J., Rooijakkers, M. J., Vullings, R., & Aarts, R. M. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/8/1204 · Cited by 48
“The number of false alarms in intensive care units (ICUs) have been reported to be 40 – 86% (Lawless 1994, Tsien and Fackler 1997, Siebig et al 2010).”
Background
Metadata
- Authors
- Siebig, S., Kuhls, S., Imhoff, M., Gather, U., Schölmerich, J., & Wrede, C. E.
- Venue
- Critical Care Medicine
- Published
- 2010-02
- Volume
- 38
- Issue
- 2
- Pages
- 451-456
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2009398155
- Cited by
- 206
- References
- 2
- FWCI
- 14.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.