CoChat

Diaphragm dysfunction assessed by ultrasonography: Influence on weaning from mechanical ventilation*

Kim, Won Young, Suh, Hee Jung, Hong, Sang-Bum, Koh, Younsuck, Lim, Chae-Man · 2011 · Critical Care Medicine
Cited by 550

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To determine the prevalence of diaphragmatic dysfunction diagnosed by M-mode ultrasonography (vertical excursion <10 mm or paradoxic movements) in medical intensive care unit patients and to assess the influence of diaphragmatic dysfunction on weaning outcome. DESIGN: Prospective, observational study. SETTING: Twenty-eight-bed medical intensive care unit in a university-affiliated hospital. PATIENTS: Eighty-eight consecutive patients in the medical intensive care unit who required mechanical ventilation over 48 hrs and met the criteria for a spontaneous breathing trial were assessed. Patients with a history of diaphragmatic or neuromuscular disease or evidence of pneumothorax or pneumomediastinum were excluded. INTERVENTIONS: During spontaneous breathing trial, each hemidiaphragm was evaluated by M-mode ultrasonography using the liver and spleen as windows with the patient supine. Rapid shallow breathing index was simultaneously calculated at the bedside. MEASUREMENTS AND MAIN RESULTS: The prevalence of ultrasonographic diaphragmatic dysfunction among the eligible 82 patients was 29% (n = 24). Patients with diaphragmatic dysfunction had longer weaning time (401 [range, 226-612] hrs vs. 90 [range, 24-309] hrs, p < .01) and total ventilation time (576 [range, 374-850] hrs vs. 203 [range, 109-408] hrs, p < .01) than patients without diaphragmatic dysfunction. Patients with diaphragmatic dysfunction also had higher rates of primary (20 of 24 vs. 34 of 58, p < .01) and secondary (ten of 20 vs. ten of 46, p = .01) weaning failures than patients without diaphragmatic dysfunction. The area under the receiver operating characteristics curve of ultrasonographic criteria in predicting weaning failure was similar to that of rapid shallow breathing index. CONCLUSIONS: Using M-mode ultrasonography, diaphragmatic dysfunction was found in a substantial number of medical intensive care unit patients without histories of diaphragmatic disease. Patients with such diaphragmatic dysfunction showed frequent early and delayed weaning failures. Ultrasonography of the diaphragm may be useful in identifying patients at high risk of difficulty weaning.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3182266408

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 10

  1. Esteban, 1994, Chest, 106, 1188, 10.1378/chest.106.4.1188 · doi:10.1378/chest.106.4.1188
  2. Zhu, 2008, Zhonghua Jie He He Hu Xi Za Zhi, 31, 616
  3. Schild, 2008, Pneumologie, 62, 33, 10.1055/s-2007-980137 · doi:10.1055/s-2007-980137
  4. Helzel, 1985, Rontgenblatter, 38, 248
  5. Fedullo, 1992, Chest, 102, 1683, 10.1378/chest.102.6.1683 · doi:10.1378/chest.102.6.1683
  6. Epelman, 2005, Pediatr Radiol, 35, 661, 10.1007/s00247-005-1433-7 · doi:10.1007/s00247-005-1433-7
  7. Lloyd, 2006, Spinal Cord, 44, 505, 10.1038/sj.sc.3101889 · doi:10.1038/sj.sc.3101889
  8. Chao, 2007, Respiratory Care, 52, 159
  9. Ayoub, 1997, Can J Anaesth, 44, 739, 10.1007/BF03013389 · doi:10.1007/bf03013389
  10. Houston, 1994, Thorax, 49, 500, 10.1136/thx.49.5.500 · doi:10.1136/thx.49.5.500

Cited by

See all 550

Metadata

Authors
Kim, W. Y., Suh, H. J., Hong, S.-B., Koh, Y., & Lim, C.-M.
Venue
Critical Care Medicine
Published
2011-12
Volume
39
Issue
12
Pages
2627-2630
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2317417416
Cited by
550
References
13
FWCI
11.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.