Diaphragm dysfunction assessed by ultrasonography: Influence on weaning from mechanical ventilation*
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine the prevalence of diaphragmatic dysfunction diagnosed by M-mode ultrasonography (vertical excursion <10 mm or paradoxic movements) in medical intensive care unit patients and to assess the influence of diaphragmatic dysfunction on weaning outcome. DESIGN: Prospective, observational study. SETTING: Twenty-eight-bed medical intensive care unit in a university-affiliated hospital. PATIENTS: Eighty-eight consecutive patients in the medical intensive care unit who required mechanical ventilation over 48 hrs and met the criteria for a spontaneous breathing trial were assessed. Patients with a history of diaphragmatic or neuromuscular disease or evidence of pneumothorax or pneumomediastinum were excluded. INTERVENTIONS: During spontaneous breathing trial, each hemidiaphragm was evaluated by M-mode ultrasonography using the liver and spleen as windows with the patient supine. Rapid shallow breathing index was simultaneously calculated at the bedside. MEASUREMENTS AND MAIN RESULTS: The prevalence of ultrasonographic diaphragmatic dysfunction among the eligible 82 patients was 29% (n = 24). Patients with diaphragmatic dysfunction had longer weaning time (401 [range, 226-612] hrs vs. 90 [range, 24-309] hrs, p < .01) and total ventilation time (576 [range, 374-850] hrs vs. 203 [range, 109-408] hrs, p < .01) than patients without diaphragmatic dysfunction. Patients with diaphragmatic dysfunction also had higher rates of primary (20 of 24 vs. 34 of 58, p < .01) and secondary (ten of 20 vs. ten of 46, p = .01) weaning failures than patients without diaphragmatic dysfunction. The area under the receiver operating characteristics curve of ultrasonographic criteria in predicting weaning failure was similar to that of rapid shallow breathing index. CONCLUSIONS: Using M-mode ultrasonography, diaphragmatic dysfunction was found in a substantial number of medical intensive care unit patients without histories of diaphragmatic disease. Patients with such diaphragmatic dysfunction showed frequent early and delayed weaning failures. Ultrasonography of the diaphragm may be useful in identifying patients at high risk of difficulty weaning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Comparison of Four Methods of Weaning Patients from Mechanical Ventilation
Esteban, A., Frutos, F., Tobin, M. J., Alía, I., Solsona, J. F., Valverdu, V., Fernández, R., de la Cal, M. A., Benito, S., Tomás, R., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199502093320601 · Cited by 1,549
Yang, K. L., & Tobin, M. J. (1991) · New England Journal of Medicine · doi:10.1056/nejm199105233242101 · Cited by 1,378
Diaphragmatic Motion Studied by M-Mode Ultrasonography
Boussuges, A., Gole, Y., & Blanc, P. (2009) · Chest · doi:10.1378/chest.08-1541 · Cited by 760
Ultrasonographic evaluation of diaphragmatic motion.
Gerscovich, E. O., Cronan, M., McGahan, J. P., Jain, K., Jones, C. D., & McDonald, C. (2001) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2001.20.6.597 · Cited by 312
Monitoring Recovery From Diaphragm Paralysis With Ultrasound
Summerhill, E. M., El-Sameed, Y. A., Glidden, T. J., & McCool, F. D. (2008) · Chest · doi:10.1378/chest.07-2200 · Cited by 254
Ultrasonographic Diagnostic Criterion for Severe Diaphragmatic Dysfunction After Cardiac Surgery
Lerolle, N., Guérot, E., Dimassi, S., Zegdi, R., Faisy, C., Fagon, J.-Y., & Diehl, J.-L. (2009) · Chest · doi:10.1378/chest.08-1531 · Cited by 238
Diaphragmatic thickness-lung volume relationship in vivo
Wait, J. L., Nahormek, P. A., Yost, W. T., & Rochester, D. P. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.4.1560 · Cited by 204
Houston, J. G., Morris, A. D., Howie, C., Reid, J. L., & McMillan, N. C. (1992) · Clinical Radiology · doi:10.1016/s0009-9260(05)80688-9 · Cited by 134
Leupeptin Inhibits Ventilator-induced Diaphragm Dysfunction in Rats
Maes, K., Testelmans, D., Powers, S., Decramer, M., & Gayan-Ramirez, G. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200609-1342oc · Cited by 118
Ventilator-induced diaphragm dysfunction: the clinical relevance of animal models
Vassilakopoulos, T. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0866-x · Cited by 88
Research works printed but not linked: 10
- Esteban, 1994, Chest, 106, 1188, 10.1378/chest.106.4.1188 · doi:10.1378/chest.106.4.1188
- Zhu, 2008, Zhonghua Jie He He Hu Xi Za Zhi, 31, 616
- Schild, 2008, Pneumologie, 62, 33, 10.1055/s-2007-980137 · doi:10.1055/s-2007-980137
- Helzel, 1985, Rontgenblatter, 38, 248
- Fedullo, 1992, Chest, 102, 1683, 10.1378/chest.102.6.1683 · doi:10.1378/chest.102.6.1683
- Epelman, 2005, Pediatr Radiol, 35, 661, 10.1007/s00247-005-1433-7 · doi:10.1007/s00247-005-1433-7
- Lloyd, 2006, Spinal Cord, 44, 505, 10.1038/sj.sc.3101889 · doi:10.1038/sj.sc.3101889
- Chao, 2007, Respiratory Care, 52, 159
- Ayoub, 1997, Can J Anaesth, 44, 739, 10.1007/BF03013389 · doi:10.1007/bf03013389
- Houston, 1994, Thorax, 49, 500, 10.1136/thx.49.5.500 · doi:10.1136/thx.49.5.500
Cited by
ERS statement on respiratory muscle testing at rest and during exercise
Laveneziana, P., Albuquerque, A., Aliverti, A., Babb, T., Barreiro, E., Dres, M., Dubé, B.-P., Fauroux, B., Gea, J., Guenette, J. A., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01214-2018 · Cited by 818
Mechanical Ventilation–induced Diaphragm Atrophy Strongly Impacts Clinical Outcomes
Goligher, E. C., Dres, M., Fan, E., Rubenfeld, G. D., Scales, D. C., Herridge, M. S., Vorona, S., Sklar, M. C., Rittayamai, N., Lanys, A., et al. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201703-0536oc · Cited by 813
Evolution of Diaphragm Thickness during Mechanical Ventilation. Impact of Inspiratory Effort
Goligher, E. C., Fan, E., Herridge, M. S., Murray, A., Vorona, S., Brace, D., Rittayamai, N., Lanys, A., Tomlinson, G., Singh, J. M., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201503-0620oc · Cited by 608
Matamis, D., Soilemezi, E., Tsagourias, M., Akoumianaki, E., Dimassi, S., Boroli, F., Richard, J.-C. M., & Brochard, L. (2013) · Intensive Care Medicine · doi:10.1007/s00134-013-2823-1 · Cited by 576
The Decision to Extubate in the Intensive Care Unit
Thille, A. W., Richard, J.-C. M., & Brochard, L. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201208-1523ci · Cited by 576
Dres, M., Dubé, B.-P., Mayaux, J., Delemazure, J., Reuter, D., Brochard, L., Similowski, T., & Demoule, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201602-0367oc · Cited by 539
Diaphragm ultrasound as a predictor of successful extubation from mechanical ventilation
DiNino, E., Gartman, E. J., Sethi, J. M., & McCool, F. D. (2014) · Thorax · doi:10.1136/thoraxjnl-2013-204111 · Cited by 487
Demoule, A., Jung, B., Prodanovic, H., Molinari, N., Chanques, G., Coirault, C., Matecki, S., Duguet, A., Similowski, T., & Jaber, S. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201209-1668oc · Cited by 459
Goligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Sebastien-Bolz, S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3687-3 · Cited by 448
Diaphragm ultrasonography to estimate the work of breathing during non-invasive ventilation
Vivier, E., Mekontso Dessap, A., Dimassi, S., Vargas, F., Lyazidi, A., Thille, A. W., & Brochard, L. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2547-7 · Cited by 406
Critical illness-associated diaphragm weakness
Dres, M., Goligher, E. C., Heunks, L. M. A., & Brochard, L. J. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4928-4 · Cited by 402
Zambon, M., Greco, M., Bocchino, S., Cabrini, L., Beccaria, P. F., & Zangrillo, A. (2017) · Intensive Care Medicine · doi:10.1007/s00134-016-4524-z · Cited by 386
Neuromuscular ultrasound for evaluation of the diaphragm
Sarwal, A., Walker, F. O., & Cartwright, M. S. (2013) · Muscle & Nerve · doi:10.1002/mus.23671 · Cited by 350
Umbrello, M., Formenti, P., Longhi, D., Galimberti, A., Piva, I., Pezzi, A., Mistraletti, G., Marini, J. J., & Iapichino, G. (2015) · Critical Care · doi:10.1186/s13054-015-0894-9 · Cited by 343
“A limitation of diaphragm sonography is a poor acoustic window; this is reported to occur in a minority of patients, varying between 2 and 10% [14,33].”
BackgroundMethodJung, B., Moury, P. H., Mahul, M., de Jong, A., Galia, F., Prades, A., Albaladejo, P., Chanques, G., Molinari, N., & Jaber, S. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4125-2 · Cited by 330
New International Guidelines and Consensus on the Use of Lung Ultrasound
Demi, L., Wolfram, F., Klersy, C., De Silvestri, A., Ferretti, V. V., Muller, M., Miller, D., Feletti, F., Wełnicki, M., Buda, N., et al. (2023) · Journal of Ultrasound in Medicine · doi:10.1002/jum.16088 · Cited by 328
Goligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Bolz, S.-S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3724-2 · Cited by 315
Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation
Ferrari, G., De Filippi, G., Elia, F., Panero, F., Volpicelli, G., & Aprà, F. (2014) · Critical Ultrasound Journal · doi:10.1186/2036-7902-6-8 · Cited by 306
Tuinman, P. R., Jonkman, A. H., Dres, M., Shi, Z.-H., Goligher, E. C., Goffi, A., de Korte, C., Demoule, A., & Heunks, L. (2020) · Intensive Care Medicine · doi:10.1007/s00134-019-05892-8 · Cited by 292
Goligher, E. C., Brochard, L. J., Reid, W. D., Fan, E., Saarela, O., Slutsky, A. S., Kavanagh, B. P., Rubenfeld, G. D., & Ferguson, N. D. (2019) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(18)30366-7 · Cited by 275
Respiratory Drive in Critically Ill Patients. Pathophysiology and Clinical Implications
Vaporidi, K., Akoumianaki, E., Telias, I., Goligher, E. C., Brochard, L., & Georgopoulos, D. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201903-0596so · Cited by 267
Monitoring of the Respiratory Muscles in the Critically Ill
Doorduin, J., van Hees, H. W. H., van der Hoeven, J. G., & Heunks, L. M. A. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201206-1117cp · Cited by 238
“Using M-mode ultrasonography, diaphragm dysfunction was found in 29% of critically ill patients without history of diaphragm dysfunction (57).”
MethodDiaphragm Dysfunction: Diagnostic Approaches and Management Strategies
Dubé, B.-P., & Dres, M. (2016) · Journal of Clinical Medicine · doi:10.3390/jcm5120113 · Cited by 230
“EXdi is usually measured using a curvilinear probe positioned in the infra-hepatic region [117], and has similarly been shown to be reproducible [134], related to transdiaphragmatic pressure [135] and to weaning outcome in intubated patients [57].”
BackgroundDubé, B.-P., Dres, M., Mayaux, J., Demiri, S., Similowski, T., & Demoule, A. (2017) · Thorax · doi:10.1136/thoraxjnl-2016-209459 · Cited by 216
Inability of Diaphragm Ultrasound to Predict Extubation Failure
Vivier, E., Muller, M., Putegnat, J.-B., Steyer, J., Barrau, S., Boissier, F., Bourdin, G., Mekontso-Dessap, A., Levrat, A., Pommier, C., et al. (2019) · Chest · doi:10.1016/j.chest.2019.03.004 · Cited by 179
Spadaro, S., Grasso, S., Mauri, T., Dalla Corte, F., Alvisi, V., Ragazzi, R., Cricca, V., Biondi, G., Di Mussi, R., Marangoni, E., et al. (2016) · Critical Care · doi:10.1186/s13054-016-1479-y · Cited by 163
“Diaphragmatic dysfunction (defined as DD <10 mm) has been found to be a predictor of weaning failure among patients in medical ICUs [19].”
BackgroundMethodResultInfluentialFarghaly, S., & Hasan, A. A. (2017) · Australian Critical Care · doi:10.1016/j.aucc.2016.03.004 · Cited by 159
Sarwal, A., Parry, S. M., Berry, M. J., Hsu, F.-C., Lewis, M. T., Justus, N. W., Morris, P. E., Denehy, L., Berney, S., Dhar, S., et al. (2015) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.34.7.1191 · Cited by 158
Er, B., Simsek, M., Yildirim, M., Halacli, B., Ocal, S., Ersoy, E. O., Demir, A. U., & Topeli, A. (2021) · Respiratory Medicine · doi:10.1016/j.rmed.2021.106503 · Cited by 24
Metadata
- Authors
- Kim, W. Y., Suh, H. J., Hong, S.-B., Koh, Y., & Lim, C.-M.
- Venue
- Critical Care Medicine
- Published
- 2011-12
- Volume
- 39
- Issue
- 12
- Pages
- 2627-2630
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2317417416
- Cited by
- 550
- References
- 13
- FWCI
- 11.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.