The DOI matches its Crossref record; 106 of the 108 references it cites were found in a registry or an index.
Nocturnal blood pressure measured by home devices: evidence and perspective for clinical application
Open accessAbstract
: Studies using ambulatory blood pressure (BP) monitoring have shown that BP during night-time sleep is a stronger predictor of cardiovascular outcomes than daytime ambulatory or conventional office BP. However, night-time ambulatory BP recordings may interfere with sleep quality because of the device cuff inflation and frequency of measurements. Hence, there is an unmet need for obtaining high quality BP values during sleep. In the last two decades, technological development of home BP devices enabled automated BP measurements during night-time. Preliminary data suggest that nocturnal home BP measurements yield similar BP values and show good agreement in detecting nondippers when compared with ambulatory BP monitoring. Thus, nocturnal home BP measurements might be a reliable and practical alternative to ambulatory BP monitoring to evaluate BP during sleep. As the use of home BP devices is widespread, well accepted by users and has relatively low cost, it may prove to be more feasible and widely available for routine clinical assessment of nocturnal BP. At present, however, data on the prognostic relevance of nocturnal BP measured by home devices, the optimal measurement schedule, and other methodological issues are lacking and await further investigation. This article offers a systematic review of the current evidence on nocturnal home BP, highlights the remaining research questions, and provides preliminary recommendations for application of this novel approach in BP management.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Even though several automated wrist devices have successfully passed international validation protocols in a laboratory setting, they are considered more prone to errors than the upper arm devices in real-life conditions [79].”
Citations
Cites
2013 ESH/ESC Guidelines for the management of arterial hypertension
Authors Task Force Members, Mancia, G., Fagard, R., Narkiewicz, K., Redon, J., Zanchetti, A., Böhm, M., Christiaens, T., Cífková, R., Backer, G. D., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,739
Self-citationCappuccio, F. P., Cooper, D., D'Elia, L., Strazzullo, P., & Miller, M. A. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr007 · Cited by 2,146
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationMarino, M., Li, Y., Rueschman, M. N., Winkelman, J. W., Ellenbogen, J. M., Solet, J. M., Dulin, H., Berkman, L. F., & Buxton, O. M. (2013) · Sleep · doi:10.5665/sleep.3142 · Cited by 1,056
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2014)
(2014) · Hypertension Research · doi:10.1038/hr.2014.20 · Cited by 1,049
Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887
Self-citationBobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationOhkubo, T., Imai, Y., Tsuji, I., Nagai, K., Kato, J., Kikuchi, N., Nishiyama, A., Aihara, A., Sekino, M., Kikuya, M., et al. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816070-00010 · Cited by 746
Self-citationBrook, R. D., & Rajagopalan, S. (2018) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2018.01.004 · Cited by 731
Increase in Nocturnal Blood Pressure and Progression to Microalbuminuria in Type 1 Diabetes
Lurbe, E., Redón, J., Kesani, A., Pascual, J. M., Tacons, J., Álvarez, V., & BATLLE, D. C. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013410 · Cited by 723
Martínez-García, M.-A., Capote, F., Campos-Rodríguez, F., Lloberes, P., Díaz de Atauri, M. J., Somoza, M., Masa, J. F., González, M., Sacristán, L., Barbé, F., et al. (2013) · JAMA · doi:10.1001/jama.2013.281250 · Cited by 685
Call to Action on Use and Reimbursement for Home Blood Pressure Monitoring
Pickering, T. G., Miller, N. H., Ogedegbe, G. G., Krakoff, L. R., Artinian, N. T., & Goff, D. C. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 666
Green, B. B. (2008) · JAMA · doi:10.1001/jama.299.24.2857 · Cited by 653
Prognostic Effect of the Nocturnal Blood Pressure Fall in Hypertensive Patients
Salles, G. F., Reboldi, G., Fagard, R. H., Cardoso, C. R. L., Pierdomenico, S. D., Verdecchia, P., Eguchi, K., Kario, K., Hoshide, S., Polónia, J. J., et al. (2016) · Hypertension · doi:10.1161/hypertensionaha.115.06981 · Cited by 525
Self-citationClinical Relevance of Nighttime Blood Pressure and of Daytime Blood Pressure Variability
Palatini, P. (1992) · Archives of Internal Medicine · doi:10.1001/archinte.1992.00400210081013 · Cited by 424
Arterial blood pressure responses to graded transient arousal from sleep in normal humans
Davies, R. J. O., Belt, P. J., Roberts, S. J., Ali, N. J., & Stradling, J. R. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.3.1123 · Cited by 314
Diagnostic Thresholds for Ambulatory Blood Pressure Monitoring Based on 10-Year Cardiovascular Risk
Kikuya, M., Hansen, T. W., Thijs, L., Björklund-Bodegård, K., Kuznetsova, T., Ohkubo, T., Richart, T., Torp-Pedersen, C., Lind, L., Ibsen, H., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.662254 · Cited by 314
Self-citationLovibond, K., Jowett, S., Barton, P., Caulfield, M., Heneghan, C., Hobbs, F. R., Hodgkinson, J., Mant, J., Martin, U., Williams, B., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61184-7 · Cited by 311
Nocturnal Hypertension: New Technology and Evidence
Kario, K. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.10971 · Cited by 298
Self-citationDay-Night Dip and Early-Morning Surge in Blood Pressure in Hypertension
Verdecchia, P., Angeli, F., Mazzotta, G., Garofoli, M., Ramundo, E., Gentile, G., Ambrosio, G., & Reboldi, G. (2012) · Hypertension · doi:10.1161/hypertensionaha.112.191858 · Cited by 287
Minutolo, R., Agarwal, R., Borrelli, S., Chiodini, P., Bellizzi, V., Nappi, F., Cianciaruso, B., Zamboli, P., Conte, G., Gabbai, F. B., et al. (2011) · Archives of Internal Medicine · doi:10.1001/archinternmed.2011.230 · Cited by 286
Roush, G. C., Fagard, R. H., Salles, G. F., Pierdomenico, S. D., Reboldi, G., Verdecchia, P., Eguchi, K., Kario, K., Hoshide, S., Polonia, J., et al. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000355 · Cited by 272
Self-citationStergiou, G. S., Baibas, N. M., Gantzarou, A. P., Skeva, I. I., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02324-x · Cited by 268
Self-citationReproducibility and clinical value of nocturnal hypotension
Omboni, S., Parati, G., Palatini, P., Vanasia, A., Muiesan, M. L., Cuspidi, C., & Mancia, G. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816060-00003 · Cited by 250
Self-citationOhkubo, T., Hozawa, A., Nagaie, K., Kikuya, M., Tsujia, I., Itoc, S., Satoh, H., Hisamichi, S., & Imaid, Y. (2000) · Journal of Hypertension · doi:10.1097/00004872-200018070-00005 · Cited by 242
Self-citationOscillometric blood pressure: a review for clinicians
Alpert, B. S., Quinn, D. E., & Gallick, D. (2014) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2014.08.014 · Cited by 213
Imai, Y., Kario, K., Shimada, K., Kawano, Y., Hasebe, N., Matsuura, H., Tsuchihashi, T., Ohkubo, T., Kuwajima, I., & Miyakawa, M. (2012) · Hypertension Research · doi:10.1038/hr.2012.56 · Cited by 204
Self-citationCuspidi, C., Meani, S., Salerno, M., Valerio, C., Fusi, V., Severgnini, B., Lonati, L. M., Magrini, F., & Zanchetti, A. (2004) · Journal of Hypertension · doi:10.1097/00004872-200402000-00010 · Cited by 195
on behalf of Hypertension Objective Treatment Based on Measurement by Electrical Devices of Blood Pressure (HOMED-BP) investigators, Asayama, K., Ohkubo, T., Metoki, H., Obara, T., Inoue, R., Kikuya, M., Thijs, L., Staessen, J. A., & Imai, Y. (2012) · Hypertension Research · doi:10.1038/hr.2012.125 · Cited by 186
Self-citationAltered circadian blood pressure rhythm in patients with Cushing's syndrome.
Imai, Y., Abe, K., Sasaki, S., Minami, N., Nihei, M., Munakata, M., Murakami, O., Matsue, K., Sekino, H., & Miura, Y. (1988) · Hypertension · doi:10.1161/01.hyp.12.1.11 · Cited by 178
Self-citationDiurnal Variation of Blood Pressure in Elderly Patients with Essential Hypertension
Kobrin, I., Oigman, W., Kumar, A., Ventura, H. O., Messerli, F. H., Frohlich, E. D., & Dunn, F. G. (1984) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1984.tb00890.x · Cited by 166
Loss of nocturnal decline in blood pressure after cardiac transplantation.
Reeves, R. A., Shapiro, A. P., Thompson, M. E., & Johnsen, A. M. (1986) · Circulation · doi:10.1161/01.cir.73.3.401 · Cited by 160
Trazzi, S., Mutti, E., Frattola, A., Imholz, B. P. M., Parati, G., & Mancia, G. (1991) · Journal of Hypertension · doi:10.1097/00004872-199102000-00003 · Cited by 158
Self-citationAsayama, K., Thijs, L., Li, Y., Gu, Y.-M., Hara, A., Liu, Y.-P., Zhang, Z., Wei, F.-F., Lujambio, I., Mena, L. J., et al. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.03614 · Cited by 157
Self-citationParati, G., Pomidossi, G. A., Casadei, R., & Mancia, G. (1985) · Hypertension · doi:10.1161/01.hyp.7.4.597 · Cited by 139
Self-citationAmbulatory Blood Pressure and Cardiovascular Outcome in Relation to Perceived Sleep Deprivation
Verdecchia, P., Angeli, F., Borgioni, C., Gattobigio, R., & Reboldi, G. (2007) · Hypertension · doi:10.1161/01.hyp.0000258215.26755.20 · Cited by 133
Imai, Y., Sasaki, S., Minami, N., Munakata, M., Hashimoto, J., Sakuma, H., Sakuma, M., Watanabe, N., Imai, K., Sekino, H., et al. (1992) · American Journal of Hypertension · doi:10.1093/ajh/5.10.719 · Cited by 130
Self-citationEguchi, K., Pickering, T. G., Schwartz, J. E., Hoshide, S., Ishikawa, J., Ishikawa, S., Shimada, K., & Kario, K. (2008) · Archives of Internal Medicine · doi:10.1001/archinte.168.20.2225 · Cited by 127
Self-citationNighttime Home Blood Pressure and the Risk of Hypertensive Target Organ Damage
Ishikawa, J., Hoshide, S., Eguchi, K., Ishikawa, S., Shimada, K., Kario, K., & for the Japan Morning Surge-Home Blood Pressure Study Investigators Group (2012) · Hypertension · doi:10.1161/hypertensionaha.112.198101 · Cited by 123
Self-citationKario, K., Hoshide, S., Shimizu, M., Yano, Y., Eguchi, K., Ishikawa, J., Ishikawa, S., & Shimada, K. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283395267 · Cited by 122
Self-citationReproducibility of Home Blood Pressure Measurements Over a 1-Year Period
Sakuma, M. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00117-9 · Cited by 122
Effect of measuring ambulatory blood pressure on sleep and on blood pressure during sleep
Davies, R. J. O., Jenkins, N., & Stradling, J. R. (1994) · BMJ · doi:10.1136/bmj.308.6932.820 · Cited by 115
White, W. B., Lund-Johansen, P., & McCabe, E. J. (1989) · Journal of Hypertension · doi:10.1097/00004872-198906000-00007 · Cited by 115
Self-citationDevice for the self-measurement of blood pressure that can monitor blood pressure during sleep
Chonan, K., Kikuya, M., Araki, T., Fujiwara, T., Suzuki, M., Michimata, M., Hashimoto, J., Ohkubo, T., Hozawa, A., Yamamoto, N., et al. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200108000-00008 · Cited by 95
Self-citationAccuracy and reliability of wrist-cuff devices for self-measurement of blood pressure
Kikuya, M., Chonan, K., Imai, Y., Gotō, E., & Ishii, M. (2002) · Journal of Hypertension · doi:10.1097/00004872-200204000-00019 · Cited by 92
Self-citationWang, C., Zhang, J., Liu, X., Li, C., Ye, Z., Peng, H., Chen, Z.-J., & Lou, T. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055419 · Cited by 91
Exogenous glucocorticoid eliminates or reverses circadian blood pressure variations
Imai, Y., Abe, K., Sasaki, S., Minami, N., Munakata, M., Nihei, M., Sekino, H., & YOSHINAGA, K. (1989) · Journal of Hypertension · doi:10.1097/00004872-198902000-00006 · Cited by 91
Self-citationKollias, A., Ntineri, A., & Stergiou, G. S. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001189 · Cited by 90
Self-citationAsayama, K., Thijs, L., Brguljan-Hitij, J., Niiranen, T. J., Hozawa, A., Boggia, J., Aparicio, L. S., Hara, A., Johansson, J. K., Ohkubo, T., et al. (2014) · PLoS Medicine · doi:10.1371/journal.pmed.1001591 · Cited by 87
Self-citationAgarwal, R., & Light, R. P. (2009) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.07011009 · Cited by 77
Kario, K., Hoshide, S., Haimoto, H., Yamagiwa, K., Uchiba, K., Nagasaka, S., Yano, Y., Eguchi, K., Matsui, Y., Shimizu, M., et al. (2015) · Journal of Clinical Hypertension · doi:10.1111/jch.12500 · Cited by 76
Self-citationStergiou, G. S., Myrsilidi, A., Κόλλιας, Α., Destounis, A., Roussias, L. G., & Kalogeropoulos, P. G. (2015) · Hypertension Research · doi:10.1038/hr.2015.96 · Cited by 73
Self-citationMancia, G., Omboni, S., Parati, G., Trazzi, S., & Mutti, E. (1992) · Journal of Hypertension · doi:10.1097/00004872-199210120-00014 · Cited by 72
Self-citationKario, K., Tomitani, N., Kanegae, H., Ishii, H., Uchiyama, K., Yamagiwa, K., Shiraiwa, T., Katsuya, T., Yoshida, T., Kanda, K., et al. (2017) · Circulation Journal · doi:10.1253/circj.cj-17-0109 · Cited by 71
Self-citationPatients’ preference for ambulatory versus home blood pressure monitoring
Nasothimiou, E. G., Karpettas, N., Dafni, M. G., & Stergiou, G. S. (2014) · Journal of Human Hypertension · doi:10.1038/jhh.2013.104 · Cited by 66
Self-citationDoes non-invasive ambulatory blood pressure monitoring disturb sleep?
Degaute, J. P., van de Borne, P., Kerkhofs, M., Dramaix, M., & Linkowski, P. (1992) · PubMed · Cited by 62
Reproducibility of ambulatory blood pressure in treated and untreated hypertensive patients
Eguchi, K., Hoshide, S., Hoshide, Y., Ishikawa, S., Shimada, K., & Kario, K. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283378477 · Cited by 60
Self-citationDetecting Sodium-Sensitivity in Hypertensive Patients
Castiglioni, P., Parati, G., Brambilla, L., Brambilla, V., Gualerzi, M., Rienzo, M. D., & Coruzzi, P. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.158972 · Cited by 58
Self-citationReproducibility of blood pressure dipping: Relation to day-to-day variability in sleep quality
Hinderliter, A. L., Routledge, F. S., Blumenthal, J. A., Koch, G. G., Hussey, M. A., Wohlgemuth, W. K., & Sherwood, A. (2013) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2013.06.001 · Cited by 58
Stergiou, G. S., Nasothimiou, E. G., Destounis, A., Poulidakis, E., Evagelou, I., & Tzamouranis, D. (2012) · American Journal of Hypertension · doi:10.1038/ajh.2012.82 · Cited by 55
Self-citationEffects of cuff inflation on self-recorded blood pressure
Veerman, D. P., van Montfrans, G. A., & Wieling, W. (1990) · The Lancet · doi:10.1016/0140-6736(90)90676-v · Cited by 53
Reproducibility of Nocturnal Blood Pressure Assessed by Self-Measurement of Blood Pressure at Home
Hosohata, K., Kikuya, M., Ohkubo, T., Metoki, H., Asayama, K., Inoue, R., Obara, T., Hashimoto, J., Totsune, K., Hoshi, H., et al. (2007) · Hypertension Research · doi:10.1291/hypres.30.707 · Cited by 51
Self-citationMancia, G., Ulian, L., Parati, G., & Trazzi, S. (1994) · PubMed · Cited by 49
Self-citationIwahori, T., Ueshima, H., Ohgami, N., Yamashita, H., Miyagawa, N., Kondo, K., Torii, S., Yoshita, K., Shiga, T., Ohkubo, T., et al. (2017) · Journal of Epidemiology · doi:10.2188/jea.je20160144 · Cited by 46
Self-citationIshikawa, J., Shimizu, M., Edison, E. S., Yano, Y., Hoshide, S., Eguchi, K., & Kario, K. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328365c8a8 · Cited by 45
Self-citationSchwan, K., & Eriksson, G. (1992) · Journal of Hypertension · doi:10.1097/00004872-199202000-00013 · Cited by 44
Acceptance and side effects of ambulatory blood pressure monitoring: evaluation of a new technology.
Beltman, F. W., Heesen, W. F., Smit, A. J., May, J. F., Lie, K. I., & Jong, B. M. (1996) · PubMed · Cited by 43
Ushio, H., Ishigami, T., Araki, N., Minegishi, S., Tamura, K., Okano, Y., Uchino, K., Tochikubo, O., & Umemura, S. (2009) · Clinical and Experimental Nephrology · doi:10.1007/s10157-009-0192-4 · Cited by 41
The Effect of Blood Pressure Cuff Inflation on Sleep A Polysomnographic Examination
Dimsdale, J. E., Coy, T. V., Ancoli‐Israel, S., Clausen, J. L., & Berry, C. C. (1993) · American Journal of Hypertension · doi:10.1093/ajh/6.10.888 · Cited by 40
Charmoy, A., Wuerzner, G., Ruffieux, C., Hasler, C., Cachat, F., Waeber, B., & Burnier, M. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3282c9ac9a · Cited by 40
Kuwabara, M., Hamasaki, H., Tomitani, N., Shiga, T., & Kario, K. (2016) · Journal of Clinical Hypertension · doi:10.1111/jch.12878 · Cited by 38
Self-citationShirasaki, O., Kuwabara, M., Saito, M., Tagami, K., Washiya, S., & Kario, K. (2011) · Hypertension Research · doi:10.1038/hr.2011.52 · Cited by 36
Self-citationNight-time home versus ambulatory blood pressure in determining target organ damage
Andreadis, E. A., Agaliotis, G. D., Κόλλιας, Α., Kolyvas, G. N., Achimastos, A. D., & Stergiou, G. S. (2016) · Journal of Hypertension · doi:10.1097/hjh.0000000000000815 · Cited by 36
Self-citationAmbulatory blood pressure monitoring does not interfere with the haemodynamic effects of sleep.
Parati, G., Pomidossi, G. A., Casadei, R., Malaspina, D., Colombo, A., Ravogli, A., & Mancia, G. (1985) · PubMed · Cited by 36
Self-citationAcceptability and tolerance of ambulatory blood pressure measurement in the hypertensive patient.
Jm, M., Gaudemaris, R. D., Baguet, J.-P., Azzouzi, L., Quesada, J., Sauzeau, C., Siche, J. P., Tremel, F., & Boutelant, S. (1996) · PubMed · Cited by 35
The importance of night-time systolic blood pressure in diabetic patients
Draman, M. S., Dolan, E., Poel, L. V. D., Tun, T. K., McDermott, J. H., Sreenan, S., & O’Brien, E. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000576 · Cited by 35
Heude, E., Bourgin, P., Feigel, P., & Escourrou, P. (1996) · Clinical Science · doi:10.1042/cs0910045 · Cited by 35
Mancia, G., Ulian, L., Parati, G., & Trazzi, S. (1994) · Journal of Hypertension · doi:10.1097/00004872-199404000-00018 · Cited by 35
Self-citationKollias, A., Andreadis, E., Agaliotis, G., Kolyvas, G. N., Achimastos, A., & Stergiou, G. S. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001562 · Cited by 34
Self-citationLindroos, A. S., Johansson, J. K., Puukka, P. J., Kantola, I. M., Salomaa, V. V., Juhanoja, E. P., Sivén, S. S. E., Jousilahti, P., Jula, A., & Niiranen, T. (2016) · Journal of Hypertension · doi:10.1097/hjh.0000000000000995 · Cited by 33
Takahashi, H., Yokoi, & Yoshika (2013) · Vascular Health and Risk Management · doi:10.2147/vhrm.s44569 · Cited by 31
Self blood pressure monitoring: a worthy substitute for ambulatory blood pressure?
McGowan, N., & Padfield, P. L. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.15 · Cited by 31
Diurnal blood pressure changes
Asayama, K., Satoh, M., & Kikuya, M. (2018) · Hypertension Research · doi:10.1038/s41440-018-0054-0 · Cited by 27
Self-citationKario, K., Ikemoto, T., Kuwabara, M., Ishiyama, H., Saito, K., & Hoshide, S. (2015) · Journal of Clinical Hypertension · doi:10.1111/jch.12759 · Cited by 25
Self-citationYarows, S. A. (2003) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2003.09.003 · Cited by 24
Reproducibility of ambulatory blood pressure changes from the initial values on two different days
Ash, G. I., Walker, T. J., Olson, K. M., Stratton, J. H., Gómez, A. L., Kraemer, W. J., Volek, J. S., & Pescatello, L. S. (2013) · Clinics · doi:10.6061/clinics/2013(12)06 · Cited by 23
Satoh, M., Asayama, K., Kikuya, M., Inoue, R., Tsubota‐Utsugi, M., Obara, T., Murakami, K., Matsuda, A., Murakami, T., Nomura, K., et al. (2017) · Clinical and Experimental Hypertension · doi:10.1080/10641963.2016.1259324 · Cited by 23
Self-citationNoninvasive Automatic Blood Pressure Monitoring Does Not Attenuate Nighttime Hypotension
Villani, A., Parati, G., Groppelli, A., Omboni, S., Rienzo, M. D., & Mancia, G. (1992) · American Journal of Hypertension · doi:10.1093/ajh/5.10.744 · Cited by 23
Self-citationKario, K., & Hamasaki, H. (2015) · Journal of Clinical Hypertension · doi:10.1111/jch.12576 · Cited by 22
Self-citationKario, K., Tomitani, N., Matsumoto, Y., Hamasaki, H., Okawara, Y., Kondo, M., Nozue, R., Yamagata, H., Okura, A., & Hoshide, S. (2016) · Annals of Global Health · doi:10.1016/j.aogh.2016.02.004 · Cited by 22
Self-citationon behalf of the Japanese Society of Hypertension Working Group on Mercury Sphygmomanometer and Minamata Convention on Mercury, Asayama, K., Ohkubo, T., Hoshide, S., Kario, K., Ohya, Y., Rakugi, H., & Umemura, S. (2016) · Hypertension Research · doi:10.1038/hr.2015.158 · Cited by 21
Self-citationVenkatraghavan, L., Sheshadri, V., Tiwari, A., & Nagappa, M. (2016) · Anesthesia Essays and Researches · doi:10.4103/0259-1162.181430 · Cited by 21
Nocturnal dipping is reproducible in the long term
McGowan, N., Gough, K., & Padfield, P. L. (2009) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32832ff4e1 · Cited by 20
Fujiwara, T., Tomitani, N., Kanegae, H., & Kario, K. (2018) · Journal of Clinical Hypertension · doi:10.1111/jch.13154 · Cited by 20
Self-citationAlessi, A., Alessi, C. R., Piana, E. R., Assis, M., Oliveira, L. R., & da Cunha, C. L. P. (2002) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2002000200010 · Cited by 18
Yatabe, M., Yatabe, J., Asayama, K., Staessen, J. A., Mujaj, B., Thijs, L., Ito, K., Sonoo, T., Morimoto, S., & Ichihara, A. (2017) · Blood Pressure · doi:10.1080/08037051.2017.1406306 · Cited by 18
Self-citationLimited reproducibility of 24-h ambulatory blood pressure monitoring.
Keren, S., Leibowitz, A., Grossman, E., & Sharabi, Y. (2015) · PubMed · doi:10.3109/10641963.2015.1036065 · Cited by 17
Comparison of Acceptability of Traditional and Novel Blood Pressure Measurement Methods
Lindroos, A. S., Jula, A., Puukka, P. J., Kantola, I. M., Salomaa, V. V., Juhanoja, E. P., Sivén, S. S. E., Jousilahti, P., & Niiranen, T. (2015) · American Journal of Hypertension · doi:10.1093/ajh/hpv167 · Cited by 15
Asleep home blood pressure monitoring in obstructive sleep apnea
Stergiou, G. S., Triantafyllidou, E., Cholidou, K. G., Κόλλιας, Α., Destounis, A., Nasothimiou, E. G., Markozannes, E., & Alchanatis, M. (2012) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32835d3608 · Cited by 15
Self-citationObjective sleep quality and night-time blood pressure in the general elderly population
Oume, M., Obayashi, K., Asai, Y., Ogura, M., Takeuchi, K., Tai, Y., Kurumatani, N., & Saeki, K. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001569 · Cited by 14
Tani, S., Asayama, K., Oiwa, K., Harasawa, S., Okubo, K., Takahashi, A., Tanabe, A., Ohkubo, T., Hirayama, A., & Kushiro, T. (2017) · Hypertension Research · doi:10.1038/hr.2017.56 · Cited by 13
Self-citationSelf-Monitoring of Ambulatory Blood Pressure by the Microlife WatchBP O3 – An Application Test
Nakano, H., Kikuya, M., Hara, A., Nakashita, M., Hirose, T., Obara, T., Metoki, H., Inoue, R., Asayama, K., Ohkubo, T., et al. (2010) · Clinical and Experimental Hypertension · doi:10.3109/10641963.2010.503300 · Cited by 12
Self-citationHead, G. A. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001244 · Cited by 9
Cuff inflations do not affect night-time blood pressure
Petersen, E. H., Theilade, S., Hansen, T. W., Lindhardt, M. K., & Rossing, P. R. (2015) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000140 · Cited by 6
O’Brien, E., Parati, G., & Stergiou, G. S. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000104 · Cited by 5
Self-citation
Research works printed but not linked: 1
- Degaute, 1992, Does noninvasive ambulatory blood pressure monitoring disturb sleep?, J Hypertens, 10, 879
Cited by
Sorted by citations
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Self-citationThe Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
Self-citationKario, K., Hoshide, S., Mizuno, H., Kabutoya, T., Nishizawa, M., Yoshida, T., Abe, H., Katsuya, T., Fujita, Y., Okazaki, O., et al. (2020) · Circulation · doi:10.1161/circulationaha.120.049730 · Cited by 324
Self-citationStergiou, G. S., Mukkamala, R., Avolio, A. P., Kyriakoulis, K. G., Mieke, S., Murray, A., Parati, G., Schutte, A. E., Sharman, J. E., Asmar, R. G., et al. (2022) · Journal of Hypertension · doi:10.1097/hjh.0000000000003224 · Cited by 231
Self-citationContinuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos
Kireev, D., Sel, K., Ibrahim, B., Kumar, N., Akbari, A., Jafari, R., & Akinwande, D. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01145-w · Cited by 249
Metadata
- Authors
- Asayama, K., Fujiwara, T., Hoshide, S., Ohkubo, T., Kario, K., Stergiou, G. S., Parati, G., White, W. B., Weber, M. A., & Imai, Y.
- Affiliations
- Tohoku Institute for Management of Blood Pressure (JP)
- Jichi Medical University (JP)
- National and Kapodistrian University of Athens (GR)
- IRCCS Istituto Auxologico Italiano (IT)
- University of Connecticut (US)
- SUNY Downstate Health Sciences University (US)
- Corresponding author
- Imai, Yutaka
- ORCID
- Venue
- Journal of Hypertension
- Published
- 2019-05
- Volume
- 37
- Issue
- 5
- Pages
- 905-916
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2921362417
- Cited by
- 120
- References
- 108
- Citations by year
- 2026: 9 · 2025: 11 · 2024: 18 · 2023: 15 · 2022: 25 · 2021: 13 · 2020: 12 · 2019: 17
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Journal of Hypertension (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Lirias (submittedVersion, other-oa)
- Funders
- Omron Healthcare
- Japan Society for the Promotion of Science (26293192)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- nocturnal blood pressure, home blood pressure monitoring, ambulatory blood pressure monitoring, non-dippers, sleep, cardiovascular risk prediction, antihypertensive therapy
- MeSH terms
- Blood Pressure, Circadian Rhythm, Humans, Hypertension, Sleep, Blood Pressure Monitoring, Ambulatory, Sphygmomanometers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›