CoChat

Ambulatory blood pressure monitoring versus self-measurement of blood pressure at home: correlation with target organ damage

Gaborieau, Valérie, Delarche, Nicolas, Gosse, Philippe · 2008 · Journal of Hypertension
Cited by 169

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Ambulatory blood pressure (BP) monitoring and home blood pressure measurements predicted the presence of target organ damage and the risk of cardiovascular events better than did office blood pressure. METHODS: To compare these two methods in their correlation with organ damage, we consecutively included 325 treated (70%) or untreated hypertensives (125 women, mean age = 64.5 +/- 11.3) with office (three measurements at two consultations), home (three measurements morning and evening over 3 days) and 24-h ambulatory monitoring. Target organs were evaluated by ECG, echocardiography, carotid echography and detection of microalbuminuria. Data from 302 patients were analyzed. RESULTS: Mean BP levels were 142/82 mmHg for office, 135.5/77 mmHg for home and 128/76 mmHg for 24-h monitoring (day = 130/78 mmHg; night = 118.5/67 mmHg). With a 135 mmHg cut-off, home and daytime blood pressure diverged in 20% of patients. Ambulatory and Home blood pressure were correlated with organ damage more closely than was office BP with a trend to better correlations with home BP. Using regression analysis, a 140 mmHg home systolic blood pressure corresponded to a 135 mmHg daytime systolic blood pressure; a 133 mmHg daytime ambulatory blood pressure and a 140 mmHg home blood pressure corresponded to the same organ damage cut-offs (Left ventricular mass index = 50 g/m, Cornell.QRS = 2440 mm/ms, carotid intima media thickness = 0.9 mm). Home-ambulatory differences were significantly associated with age and antihypertensive treatment. CONCLUSION: We showed that home blood pressure was at least as well correlated with target organ damage, as was the ambulatory blood pressure. Home-ambulatory correlation and their correlation with organ damage argue in favor of different cut-offs, that are approximately 5 mmHg higher for systolic home blood pressure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e32830c4368

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 169

Metadata

Authors
Gaborieau, V., Delarche, N., & Gosse, P.
Venue
Journal of Hypertension
Published
2008-10
Volume
26
Issue
10
Pages
1919-1927
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2052893344
Cited by
169
References
10
FWCI
4.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.