OBJECTIVE: Ambulatory blood pressure (BP) monitoring and home blood pressure measurements predicted the presence of target organ damage and the risk of cardiovascular events better than did office blood pressure. METHODS: To compare these two methods in their correlation with organ damage, we consecutively included 325 treated (70%) or untreated hypertensives (125 women, mean age = 64.5 +/- 11.3) with office (three measurements at two consultations), home (three measurements morning and evening over 3 days) and 24-h ambulatory monitoring. Target organs were evaluated by ECG, echocardiography, carotid echography and detection of microalbuminuria. Data from 302 patients were analyzed. RESULTS: Mean BP levels were 142/82 mmHg for office, 135.5/77 mmHg for home and 128/76 mmHg for 24-h monitoring (day = 130/78 mmHg; night = 118.5/67 mmHg). With a 135 mmHg cut-off, home and daytime blood pressure diverged in 20% of patients. Ambulatory and Home blood pressure were correlated with organ damage more closely than was office BP with a trend to better correlations with home BP. Using regression analysis, a 140 mmHg home systolic blood pressure corresponded to a 135 mmHg daytime systolic blood pressure; a 133 mmHg daytime ambulatory blood pressure and a 140 mmHg home blood pressure corresponded to the same organ damage cut-offs (Left ventricular mass index = 50 g/m, Cornell.QRS = 2440 mm/ms, carotid intima media thickness = 0.9 mm). Home-ambulatory differences were significantly associated with age and antihypertensive treatment. CONCLUSION: We showed that home blood pressure was at least as well correlated with target organ damage, as was the ambulatory blood pressure. Home-ambulatory correlation and their correlation with organ damage argue in favor of different cut-offs, that are approximately 5 mmHg higher for systolic home blood pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chobanian, A. V., Bakris, G. L., Black, H. R., Cushman, W. C., Green, L. A., Izzo, J. L., Jones, D. W., Materson, B. J., Oparil, S., Wright, J. T., et al. (2003) · Hypertension · doi:10.1161/01.hyp.0000107251.49515.c2 · Cited by 13,271
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Prognostic Value of Ambulatory Blood-Pressure Recordings in Patients with Treated Hypertension
Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., de Leeuw, P. W., Duprez, D. A., Fagard, R. H., Gheeraert, P. J., Missault, L. H., Braun, J. J., Six, R. O., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022273 · Cited by 1,085
Sega, R., Facchetti, R., Bombelli, M., Cesana, G., Corrao, G., Grassi, G., & Mancia, G. (2005) · Circulation · doi:10.1161/01.cir.0000160923.04524.5b · Cited by 1,009
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Mancia, G., Zanchetti, A., Agebiti-Rosei, E., Benemio, G., De Cesaris, R., Fogari, R., Pessino, A., Porcellati, C., Salvetti, A., & Trimarco, B. (1997) · Circulation · doi:10.1161/01.cir.95.6.1464 · Cited by 596
Kikuya, M., Ohkubo, T., Asayama, K., Metoki, H., Obara, T., Saito, S., Hashimoto, J., Totsune, K., Hoshi, H., Satoh, H., et al. (2005) · Hypertension · doi:10.1161/01.hyp.0000152079.04553.2c · Cited by 417
Ambulatory Blood Pressure and Mortality: A Population-Based Study
Hansen, T. W., Jeppesen, J., Rasmussen, S., Ibsen, H., & Torp-Pedersen, C. (2005) · Hypertension · doi:10.1161/01.hyp.0000160402.39597.3b · Cited by 317
Diagnostic Thresholds for Ambulatory Blood Pressure Monitoring Based on 10-Year Cardiovascular Risk
Kikuya, M., Hansen, T. W., Thijs, L., Björklund-Bodegård, K., Kuznetsova, T., Ohkubo, T., Richart, T., Torp-Pedersen, C., Lind, L., Ibsen, H., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.662254 · Cited by 314
DESIMONE, G., KIZER, J., CHINALI, M., ROMAN, M., BELLA, J., BEST, L., LEE, E., & DEVEREUX, R. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2004.08.032 · Cited by 233
Cited by
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
Diretrizes Brasileiras de Hipertensão Arterial – 2020
Barroso, W. K. S., Rodrigues, C. I. S., Bortolotto, L. A., Mota-Gomes, M. A., Brandão, A. A., Feitosa, A. D. D. M., Machado, C. A., Poli-de-Figueiredo, C. E., Amodeo, C., Mion, D., et al. (2021) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20201238 · Cited by 1,068
Daskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Mancia, G., Fagard, R., Narkiewicz, K., Redon, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Blood Pressure · doi:10.3109/08037051.2013.812549 · Cited by 426
Bliziotis, I. A., Destounis, A., & Stergiou, G. S. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283531eaf · Cited by 261
“Unauth Journal of Hypertension and methods for GFR estimation, pooling of the data was not possible.”
BackgroundMethodInfluentialReboussin, D. M., Allen, N. B., Griswold, M. E., Guallar, E., Hong, Y., Lackland, D. T., Miller, E. (. R., Polonsky, T., Thompson-Paul, A. M., & Vupputuri, S. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.004 · Cited by 221
“Observational studies suggest that the association of self-measured BP with target organ damage, such as left ventricular hypertrophy, is comparable to ambulatory blood pressure monitoring (ABPM), and superior to office-measured BP (11, 12).”
ResultFranklin, S. S., Thijs, L., Hansen, T. W., Li, Y., Boggia, J., Kikuya, M., Björklund-Bodegård, K., Ohkubo, T., Jeppesen, J., Torp-Pedersen, C., et al. (2012) · Hypertension · doi:10.1161/hypertensionaha.111.180653 · Cited by 184
Home Blood Pressure Monitoring in the Diagnosis and Treatment of Hypertension: A Systematic Review
Stergiou, G. S., & Bliziotis, I. A. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2010.194 · Cited by 182
Reboussin, D. M., Allen, N. B., Griswold, M. E., Guallar, E., Hong, Y., Lackland, D. T., Miller, E. (. R., Polonsky, T., Thompson-Paul, A. M., & Vupputuri, S. (2018) · Hypertension · doi:10.1161/hyp.0000000000000067 · Cited by 175
(2022) · PubMed Central · doi:10.6515/acs.202205_38(3).20220321a · Cited by 117
Home blood pressure monitoring: Australian Expert Consensus Statement
Sharman, J. E., Howes, F. S., Head, G. A., McGrath, B. P., Stowasser, M., Schlaich, M., Glasziou, P., & Nelson, M. R. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000673 · Cited by 83
“Compared with clinic BP, home BP has stronger associations with hypertensive target organ disease [30–34], as well as being a better predictor of cardiovascular events and mortality [35–41].”
Hara, A., Tanaka, K., Ohkubo, T., Kondo, T., Kikuya, M., Metoki, H., Hashimoto, T., Satoh, M., Inoue, R., Asayama, K., et al. (2012) · Hypertension · doi:10.1161/hypertensionaha.111.174938 · Cited by 79
Mancia, G., Facchetti, R., Seravalle, G., Cuspidi, C., Corrao, G., & Grassi, G. (2021) · Hypertension · doi:10.1161/hypertensionaha.120.16303 · Cited by 37
Self blood pressure monitoring: a worthy substitute for ambulatory blood pressure?
McGowan, N., & Padfield, P. L. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.15 · Cited by 31
Her, A.-Y., Kim, Y. H., Rim, S.-J., Kim, J.-Y., Choi, E.-Y., Min, P.-K., Lee, B.-K., Hong, B.-K., & Kwon, H. M. (2014) · Anadolu Kardiyoloji Dergisi/The Anatolian Journal of Cardiology · doi:10.5152/akd.2014.5119 · Cited by 12
Metadata
- Authors
- Gaborieau, V., Delarche, N., & Gosse, P.
- Venue
- Journal of Hypertension
- Published
- 2008-10
- Volume
- 26
- Issue
- 10
- Pages
- 1919-1927
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2052893344
- Cited by
- 169
- References
- 10
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.