Fully implantable, battery-free wireless optoelectronic devices for spinal optogenetics
Open accessThe DOI matches its Crossref record; 42 of the 43 references it cites were found in a registry or an index.
Abstract
The advent of optogenetic tools has allowed unprecedented insights into the organization of neuronal networks. Although recently developed technologies have enabled implementation of optogenetics for studies of brain function in freely moving, untethered animals, wireless powering and device durability pose challenges in studies of spinal cord circuits where dynamic, multidimensional motions against hard and soft surrounding tissues can lead to device degradation. We demonstrate here a fully implantable optoelectronic device powered by near-field wireless communication technology, with a thin and flexible open architecture that provides excellent mechanical durability, robust sealing against biofluid penetration and fidelity in wireless activation, thereby allowing for long-term optical stimulation of the spinal cord without constraint on the natural behaviors of the animals. The system consists of a double-layer, rectangular-shaped magnetic coil antenna connected to a microscale inorganic light-emitting diode (μ-ILED) on a thin, flexible probe that can be implanted just above the dura of the mouse spinal cord for effective stimulation of light-sensitive proteins expressed in neurons in the dorsal horn. Wireless optogenetic activation of TRPV1-ChR2 afferents with spinal μ-ILEDs causes nocifensive behaviors and robust real-time place aversion with sustained operation in animals over periods of several weeks to months. The relatively low-cost electronics required for control of the systems, together with the biocompatibility and robust operation of these devices will allow broad application of optogenetics in future studies of spinal circuits, as well as various peripheral targets, in awake, freely moving and untethered animals, where existing approaches have limited utility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For instance, flexible deep brain needles or wires offers the most widely adopted carrier for optogenetic localization of cellular-scale stimulation in brain.[342,563–568]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [566]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This radio frequency-based optogenetics device and its successful operation for up to four weeks represent a novel stride into closed-loop wireless optogenetic modulation for expediting the adoption of optogenetics technologies in clinical applications (Figure 15H).[566]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [566]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Millisecond-timescale, genetically targeted optical control of neural activity
Boyden, E. S., Zhang, F., Bamberg, E., Nagel, G., & Deisseroth, K. (2005) · Nature Neuroscience · doi:10.1038/nn1525 · Cited by 4,861 · cited 1×
“The advent of optogenetics allows for temporally precise control of neuronal populations with light by targeted expression of light-sensitive proteins or opsins.(5,12) Optogenetic”
BackgroundThe development and application of optogenetics
Fenno, L., Yizhar, O., & Deisseroth, K. (2011) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-061010-113817 · Cited by 1,822 · cited 1×
“approaches are extensively applied in the neuroscience community to interrogate the causal role of neural circuits in mediating various behaviors.(1,3,10,14,15,23,28,31) Although optogenetics has”
BackgroundA toolbox of Cre-dependent optogenetic transgenic mice for light-induced activation and silencing
Madisen, L., Mao, T., Koch, H., Zhuo, J.-M., Berenyi, A., Fujisawa, S., Hsu, Y.-W. A., Garcia, A. J., Gu, X., Zanella, S., et al. (2012) · Nature Neuroscience · doi:10.1038/nn.3078 · Cited by 1,398
Optogenetics: 10 years of microbial opsins in neuroscience
Deisseroth, K. (2015) · Nature Neuroscience · doi:10.1038/nn.4091 · Cited by 1,283 · cited 1×
“The advent of optogenetics allows for temporally precise control of neuronal populations with light by targeted expression of light-sensitive proteins or opsins.(5,12) Optogenetic”
BackgroundInjectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174 · cited 1×
“Recent advances in materials science have allowed for the development of ultraminiaturized LEDs, powered and controlled wirelessly and suitable for use as a device implant for optogenetic stimulation of the brain, and the spinal cord.(7,18,22,27,32,34,35) The original embodiments involved operation in RF (radio freque…”
BackgroundSelf-citationJin, S.-X., Zhuang, Z.-Y., Woolf, C. J., & Ji, R.-R. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-10-04017.2003 · Cited by 853 · cited 1×
“3C–F), consistent with previous reports.(20,35,42) We next examined the functionality and tolerability of these devices in freely moving animals.”
ResultReaChR: a red-shifted variant of channelrhodopsin enables deep transcranial optogenetic excitation
Lin, J. Y., Knutsen, P. M., Muller, A., Kleinfeld, D., & Tsien, R. Y. (2013) · Nature Neuroscience · doi:10.1038/nn.3502 · Cited by 835 · cited 1×
“Further improvements in light-dependent modulation of cells or circuits deeper in the spinal cord could be achieved using longer wavelength light in combination with redshifted opsins.(9,24,41) The deviceswe describe here are capable of powerful illumination of$ 50mW/mm(2), and can be fitted with red m-ILEDs.”
BackgroundSoft, stretchable, fully implantable miniaturized optoelectronic systems for wireless optogenetics
Park, S. I., Brenner, D. S., Shin, G., Morgan, C. D., Copits, B. A., Chung, H. U., Pullen, M. Y., Noh, K. N., Davidson, S., Oh, S. J., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3415 · Cited by 794 · cited 7×
“2C).(11,32,35) Here, wireless performance is assessed by the examination of 2 components, the Q-factor and the observed resonance frequency.”
BackgroundMethodResultInfluentialSelf-citationZhuang, Z.-Y., Gerner, P., Woolf, C. J., & Ji, R.-R. (2005) · Pain · doi:10.1016/j.pain.2004.12.022 · Cited by 774
Canales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668 · cited 1×
“Recent advances in materials science have allowed for the development of ultraminiaturized LEDs, powered and controlled wirelessly and suitable for use as a device implant for optogenetic stimulation of the brain, and the spinal cord.(7,18,22,27,32,34,35) The original embodiments involved operation in RF (radio freque…”
Background
Research works printed but not linked: 3
- Davis JR. ASM Specialty Handbook: Copper and Copper Alloys. USA: ASM international; 2001. [Google Scholar]
- Park SI, Brenner DS, Shin G, Morgan CD, Copits BA, Chung HU, Pullen MY, Noh KN, Davidson S, Oh SJ, Yoon J, Jang KI, Samineni VK, Norman M, Grajales-Reyes JG, Vogt SK, Sundaram SS, Wilson KM, Ha JS, Xu R, Pan T, Kim TI, Huang Y, Montana MC, Golden JP, Bruchas MR, Gereau RW, IV, Rogers JA. Soft, stretchable, fully implantable miniaturized optoelectronic systems for wireless optogenetics. Nat Biotechnol. 2015;33(12):1280–1286. doi: 10.1038/nbt.3415. [DOI] [PMC free article] [PubMed] [Google Scholar] · DOI · Paper page
- Park SI, Shin G, Banks A, McCall JG, Siuda ER, Schmidt MJ, Chung HU, Noh KN, Mun JG, Rhodes J, Bruchas MR, Rogers JA. Ultraminiaturized photovoltaic and radio frequency powered optoelectronic systems for wireless optogenetics. J Neural Eng. 2015;12(5):056002. doi: 10.1088/1741-2560/12/5/056002. [DOI] [PMC free article] [PubMed] [Google Scholar] · DOI · Paper page
Cited by
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G.-H., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 667
Flexible Hybrid Electronics for Digital Healthcare
Ma, Y., Zhang, Y., Cai, S., Han, Z., Liu, X., Wang, F., Cao, Y., Wang, Z., Li, H., Chen, Y., et al. (2020) · Advanced Materials · doi:10.1002/adma.201902062 · Cited by 620
Self-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
A wireless closed-loop system for optogenetic peripheral neuromodulation
Mickle, A. D., Won, S. M., Noh, K. N., Yoon, J., Meacham, K. W., Xue, Y., McIlvried, L. A., Copits, B. A., Samineni, V. K., Crawford, K. E., et al. (2019) · Nature · doi:10.1038/s41586-018-0823-6 · Cited by 514
Self-citationElectrospinning: An enabling nanotechnology platform for drug delivery and regenerative medicine
Chen, S., Li, R., Li, X., & Xie, J. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.05.001 · Cited by 383
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Self-citationFlexible and Stretchable Antennas for Biointegrated Electronics
Xie, Z., Avila, R., Huang, Y., & Rogers, J. A. (2020) · Advanced Materials · doi:10.1002/adma.201902767 · Cited by 262
Self-citation3D Printed Functional and Biological Materials on Moving Freeform Surfaces
Zhu, Z., Guo, S., Hirdler, T., Eide, C., Fan, X., Tolar, J., & McAlpine, M. C. (2018) · Advanced Materials · doi:10.1002/adma.201707495 · Cited by 245
Tissue-adhesive wirelessly powered optoelectronic device for metronomic photodynamic cancer therapy
Yamagishi, K., Kirino, I., Takahashi, I., Amano, H., Takeoka, S., Morimoto, Y., & Fujie, T. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0261-7 · Cited by 241
Advanced Energy Harvesters and Energy Storage for Powering Wearable and Implantable Medical Devices
Gao, Z., Zhou, Y., Zhang, J., Foroughi, J., Peng, S., Baughman, R. H., Wang, Z. L., & Wang, C. H. (2024) · Advanced Materials · doi:10.1002/adma.202404492 · Cited by 231
Gutruf, P., Yin, R. T., Lee, K. B., Ausra, J., Brennan, J. A., Qiao, Y., Xie, Z., Peralta, R., Talarico, O., Murillo, A., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-13637-w · Cited by 220
Self-citationGutruf, P., Krishnamurthi, V., Vázquez-Guardado, A., Xie, Z., Banks, A., Su, C.-J., Xu, Y., Haney, C. R., Waters, E. A., Kandela, I., et al. (2018) · Nature Electronics · doi:10.1038/s41928-018-0175-0 · Cited by 210
Self-citationRecent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
Self-citationRecent advances in neurotechnologies with broad potential for neuroscience research
Vázquez-Guardado, A., Yang, Y., Bandodkar, A. J., & Rogers, J. A. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-00739-8 · Cited by 202
Self-citationZhang, Y., Mickle, A. D., Gutruf, P., McIlvried, L. A., Guo, H., Wu, Y., Golden, J. P., Xue, Y., Grajales-Reyes, J. G., Wang, X., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw5296 · Cited by 195
Self-citationTowards translational optogenetics
Bansal, A., Shikha, S., & Zhang, Y. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00829-3 · Cited by 166
Metasurfaces for bioelectronics and healthcare
Li, Z., Tian, X., Qiu, C.-W., & Ho, J. S. (2021) · Nature Electronics · doi:10.1038/s41928-021-00589-7 · Cited by 159
Printing Flexible and Hybrid Electronics for Human Skin and Eye‐Interfaced Health Monitoring Systems
Kim, K., Kim, B., & Lee, C. H. (2020) · Advanced Materials · doi:10.1002/adma.201902051 · Cited by 147
Optophysiology: Illuminating cell physiology with optogenetics
Tan, P., He, L., Huang, Y., & Zhou, Y. (2022) · Physiological Reviews · doi:10.1152/physrev.00021.2021 · Cited by 155
Self-citationCho, Y., Park, S., Lee, J., & Yu, K. J. (2021) · Advanced Materials · doi:10.1002/adma.202005786 · Cited by 151
Ultra‐Deformable and Tissue‐Adhesive Liquid Metal Antennas with High Wireless Powering Efficiency
Yamagishi, K., Zhou, W., Ching, T., Huang, S. Y., & Hashimoto, M. (2021) · Advanced Materials · doi:10.1002/adma.202008062 · Cited by 137
Intravital imaging to study cancer progression and metastasis
Entenberg, D. R., Oktay, M. H., & Condeelis, J. S. (2022) · Nature reviews. Cancer · doi:10.1038/s41568-022-00527-5 · Cited by 134
Wireless closed-loop optogenetics across the entire dorsoventral spinal cord in mice
Kathe, C., Michoud, F., Schönle, P., Rowald, A., Brun, N., Ravier, J., Furfaro, I., Paggi, V., Kim, K., Soloukey, S., et al. (2022) · Nature Biotechnology · doi:10.1038/s41587-021-01019-x · Cited by 119
Clinical presentation, management, and pathophysiology of neuropathic itch
Steinhoff, M. S., Schmelz, M., Szabó, I. L., & Oaklander, A. L. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30217-5 · Cited by 116
Near-Field Communication Sensors
Cao, Z., Chen, P., Ma, Z., Li, S., Gao, X., Wu, R.-X., Pan, L., & Shi, Y. (2019) · Sensors · doi:10.3390/s19183947 · Cited by 100
“When the smartphone is close to the WISP device, the NFC chips can collect additional wireless power from NFC-enabled smartphones [76,93,94].”
BackgroundAdvances in Soft Bioelectronics for Brain Research and Clinical Neuroengineering
Sunwoo, S., Han, S. I., Joo, H., Cha, G. D., Kim, D., Choi, S. H., Hyeon, T., & Kim, D. (2020) · Matter · doi:10.1016/j.matt.2020.10.020 · Cited by 115
Conformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Ultra-Small Wearable Flexible Biosensor for Continuous Sweat Analysis
Wang, J., Wang, L., Li, G., Yan, D., Liu, C., Xu, T., & Zhang, X. (2022) · ACS Sensors · doi:10.1021/acssensors.2c01533 · Cited by 107
Cao, Y., Zhang, G., Zhang, Y., Yue, M., Chen, Y., Cai, S., Xie, T., & Feng, X. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201804604 · Cited by 93
Self-citationBandodkar, A. J., Choi, J., Lee, S. P., Jeang, W. J., Agyare, P., Gutruf, P., Wang, S., Sponenburg, R. A., Reeder, J. T., Schon, S., et al. (2019) · Advanced Materials · doi:10.1002/adma.201902109 · Cited by 92
Self-citationInjectable Biomedical Devices for Sensing and Stimulating Internal Body Organs
Jung, Y. H., Kim, J. U., Lee, J. S., Shin, J. H., Jung, W., Ok, J., & Kim, T. (2020) · Advanced Materials · doi:10.1002/adma.201907478 · Cited by 87
Self-citationAusra, J., Wu, M., Zhang, X., Vázquez‐Guardado, A., Skelton, P. D., Peralta, R., Avila, R. O., Murickan, T., Haney, C. R., Huang, Y. Y., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2025775118 · Cited by 81
“Operational area and volume are 4,900 cm(2) and 68,600 cm(3), respectively, reflecting a 444% increase in surface area and 408% increase in volume over prior work (1, 3, 4).”
BackgroundSelf-citationWireless and battery-free platforms for collection of biosignals
Stuart, T., Cai, L., Burton, A., & Gutruf, P. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113007 · Cited by 82
Printed nanofilms mechanically conforming to living bodies
Yamagishi, K., Takeoka, S., & Fujie, T. (2019) · Biomaterials Science · doi:10.1039/c8bm01290c · Cited by 77
Wireless battery free fully implantable multimodal recording and neuromodulation tools for songbirds
Ausra, J., Munger, S. J., Azami, A., Burton, A., Peralta, R., Miller, J. E., & Gutruf, P. (2021) · Nature Communications · doi:10.1038/s41467-021-22138-8 · Cited by 66
Insights Into Spinal Dorsal Horn Circuit Function and Dysfunction Using Optical Approaches
Harding, E. K., Fung, S. W., & Bonin, R. P. (2020) · Frontiers in Neural Circuits · doi:10.3389/fncir.2020.00031 · Cited by 63
A guide to the optogenetic regulation of endogenous molecules
Manoilov, K. Y., Verkhusha, V. V., & Shcherbakova, D. M. (2021) · Nature Methods · doi:10.1038/s41592-021-01240-1 · Cited by 60
Karatum, O., Gwak, M.-J., Hyun, J., Önal, A., Koirala, G. R., Kim, T., & Nizamoğlu, S. (2023) · Chemical Society Reviews · doi:10.1039/d2cs01020h · Cited by 60
Kim, H., Kim, M. J., Kwon, Y. W., Jeon, S., Lee, S., Kim, C., Choi, B. T., Shin, Y., Hong, S. W., & Shin, H. K. (2022) · Advanced Science · doi:10.1002/advs.202104629 · Cited by 52
Wireless Battery-free and Fully Implantable Organ Interfaces
Bhatia, A., Hanna, J., Stuart, T., Kasper, K. A., Clausen, D. M., & Gutruf, P. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00425 · Cited by 54
Recent progress of skin-integrated electronics for intelligent sensing
Li, D., Yao, K., Gao, Z., Liu, Y., & Yu, X. (2021) · Light Advanced Manufacturing · doi:10.37188/lam.2021.004 · Cited by 52
Nelson, T. S., Sinha, G. P., dos Santos, D. F. D. S., Jukkola, P. I., Prasoon, P., Winter, M. K., McCarson, K. E., Smith, B. N., & Taylor, B. K. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2204515119 · Cited by 50
“awake and freely moving mice, we took advantage of newly developed wireless, lightweight, flexible, and implantable optoelectronic devices (84, 85).”
BackgroundDissecting the Neural Circuitry for Pain Modulation and Chronic Pain: Insights from Optogenetics
Guo, F., Du, Y., Qu, F.-H., Lin, S.-D., Chen, Z., & Zhang, S. (2022) · Neuroscience Bulletin · doi:10.1007/s12264-022-00835-8 · Cited by 45
“Along with the improvement of devices and methodology, the application of optogenetics at the spinal level helps elucidate the cellular, molecular, and circuit mechanisms of pain transmission and integration with less tissue damage [22, 29].”
Wirelessly Operated, Implantable Optoelectronic Probes for Optogenetics in Freely Moving Animals
Zhao, Y., Liu, C., Liu, Z., Luo, W., Li, L., Cai, X., Dong, L., Su, Y., Ding, H., Wang, Q., et al. (2018) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2018.2882397 · Cited by 41
“Sputtered layers of 10 nm Cr/800 nm Cu/200 nm Au serve as the metalized electrode, and dip-coated polyisobutylene (8% w/v in heptane, thickness ∼7 μm, from J&K Scientific) and PDMS (mixed at 10:1 ratio, thickness ∼30 μm, Sylgard 184, DowCorning) layers [21] work as a waterproof encapsulation.”
MethodRestoring Function After Severe Spinal Cord Injury Through BioLuminescent-OptoGenetics
Petersen, E. D., Sharkey, E. D., Pal, A., Shafau, A.-L., Zenchak, J. R., Peña, A. J., Aggarwal, A., Prakash, M., & Hochgeschwender, U. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2021.792643 · Cited by 40
A bright future? Optogenetics in the periphery for pain research and therapy
Mickle, A. D., & Gereau, R. W. (2018) · Pain · doi:10.1097/j.pain.0000000000001329 · Cited by 39
Self-citationSoft–Hard Composites for Bioelectric Interfaces
Lin, Y., Fang, Y., Yue, J., & Tian, B. (2020) · Trends in Chemistry · doi:10.1016/j.trechm.2020.03.005 · Cited by 37
IL-23 Enhances C-Fiber-Mediated and Blue Light-Induced Spontaneous Pain in Female Mice
Ji, J., He, Q., Luo, X., Bang, S., Matsuoka, Y., McGinnis, A., Nackley, A. G., & Ji, R. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.787565 · Cited by 36
Optogenetics and its application in pain and anxiety research
Jarrin, S., & Finn, D. P. (2019) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2019.08.007 · Cited by 35
Lee, J., Parker, K. E., Kawakami, C., Kim, J. R., Qazi, R., Yea, J., Zhang, S., Kim, C. Y., Bilbily, J., Xiao, J., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202004285 · Cited by 34
Self-citationGrajales‐Reyes, J. G., Copits, B. A., Lie, F., Yu, Y., Avila, R. O., Vogt, S. K., Huang, Y. Y., Banks, A. R., Rogers, J. A., Gereau, R. W., et al. (2021) · Nature Protocols · doi:10.1038/s41596-021-00532-2 · Cited by 33
Self-citationSoft, Flexible, and Stretchable Platforms for Tissue‐Interfaced Bioelectronics
Yamagishi, K., Lee, S., Yokota, T., & Someya, T. (2026) · Advanced Science · doi:10.1002/advs.202521521 · Cited by 33
DeBerry, J. J., Samineni, V. K., Copits, B. A., Sullivan, C. J., Vogt, S. K., Albers, K. M., Davis, B. M., & Gereau, R. W. (2018) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2018.00005 · Cited by 30
Self-citationTruong, T., Nguyen, T., Huang, X., Ashok, A., Yadav, S., Park, Y., Thai, M. T., Nguyen, N., Fallahi, H., Peng, S., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202211781 · Cited by 28
Self-citationA micro-LED implant and technique for optogenetic stimulation of the rat spinal cord
Mondello, S. E., Pedigo, B. D., Sunshine, M. D., Fischedick, A. E., Horner, P. J., & Moritz, C. T. (2020) · Experimental Neurology · doi:10.1016/j.expneurol.2020.113480 · Cited by 28
“The current device is one of the few spinal implants to be designed for optogenetic stimulation in rats, with the majority of approaches targeting mice (Lu et al., 2017, 2014; Montgomery et al., 2015; Park et al., 2015; Samineni et al., 2017).”
BackgroundKumari, L. S., & Kouzani, A. Z. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2022.3141369 · Cited by 27
Ikefuama, E. C., Kendziorski, G., Anderson, K. A., Shafau, A.-L., Prakash, M., Hochgeschwender, U., & Petersen, E. D. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms232112994 · Cited by 25
Mayer, P., Sivakumar, N., Pritz, M., Varga, M., Mehmann, A., Lee, S., Salvatore, A., Magno, M., Pharr, M., Johannssen, H. C., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00819 · Cited by 24
“The scattering during penetration through the spinal cord white and gray matter tissue has been shown to decreases the power of the excitation light by 65–75% at a depth of 250 μm (Samineni et al., 2017).”
BackgroundOptogenetic Modulation of Neural Progenitor Cells Improves Neuroregenerative Potential
Giraldo, E., Palmero-Canton, D., Martínez-Rojas, B., Sánchez-Martín, M. D. M., & Moreno‐Manzano, V. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms22010365 · Cited by 24
“Additionally, our results regarding the effects of optogenetic stimulation on NPC differentiation and maturation revealed the potential of in vivo optogenetic stimulation after transplantation, which has been recently enabled by the development of small, wireless, and fully-internal implants for light-mediated stimula…”
BackgroundSoft, wireless and subdermally implantable recording and neuromodulation tools
Cai, L., & Gutruf, P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe805 · Cited by 24
Neurohumoral Cardiac Regulation: Optogenetics Gets Into the Groove
Scalco, A., Moro, N., Mongillo, M., & Zaglia, T. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.726895 · Cited by 25
Optogenetics and photopharmacology in pain research and therapeutics
Iseppon, F., & Arcangeletti, M. (2020) · STEMedicine · doi:10.37175/stemedicine.v1i3.43 · Cited by 23
“The most recent versions of these devices use near-field power coupling and radio frequencies transmission to power and activate the LEDs, as well as softer and more durable encapsulation of the microcircuits, strategies that reduce both the fabrication cost and the technical expertise necessary to produce such device…”
BackgroundWiggin, T. D., Montgomery, J. E., Brunick, A. J., Peck, J. H., & Masino, M. A. (2022) · eNeuro · doi:10.1523/eneuro.0476-21.2022 · Cited by 25
Li, J., & Baccei, M. L. (2019) · Journal of Neuroscience · doi:10.1523/jneurosci.0509-19.2019 · Cited by 21
“Chemogenetic (Peirs et al., 2015; Christensen et al., 2016) or optogenetic (François et al., 2017; Samineni et al., 2017) strategies could elucidate whether enhancing the activation of GABAergic neurons in the adult SDH can reverse the behavioral manifestations of neonatal priming.”
BackgroundXu, Z., Agbigbe, O., Nigro, N., Yakobi, G., Shapiro, J., & Ginosar, Y. (2021) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2021.102981 · Cited by 18
Widman, A. J., Bashar, T., Burton, A., Clausen, D. M., Gupta, P., Wolf, D. K., Folarin‐Hines, J., Payne, M., Rogers, J. A., Meacham, K., et al. (2025) · Advanced Science · doi:10.1002/advs.202415963 · Cited by 18
Self-citationLamkaddem, A., Yousfi, A. E., Huang, Y., González‐Posadas, V., & Segovia-Vargas, D. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3587334 · Cited by 18
“The SC stimulation device needs to be as small as 23 × 22 × 7 mm 2 [37], [38].”
Self-citationFlexible and Soft Materials and Devices for Neural Interface
Castagnola, E., Zheng, X. S., & Cui, X. T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_5 · Cited by 15
Gutruf, P., Good, C. H., & Rogers, J. A. (2018) · APL Photonics · doi:10.1063/1.5040256 · Cited by 15
Self-citationFrederick, R. A., Shih, E., Towle, V. L., Joshi‐Imre, A., Troyk, P. R., & Cogan, S. F. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.876032 · Cited by 13
“Power supply for wireless neural interfaces is most often accomplished with near-field magnetic resonant coupling (Samineni et al., 2017; Gutruf et al., 2018; Won et al., 2021).”
BackgroundDesign of the Magnetic Stamp Film for Electromagnetic-Assisted Transfer Printing
Yu, Q., Li, A., Yu, X., Zhou, H., & Cheng, H. (2021) · Journal of Applied Mechanics · doi:10.1115/1.4050536 · Cited by 13
Optogenetic Control of the Peripheral Nervous System
Chang, R. B. (2019) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a034397 · Cited by 13
“An alternative strategy is to illuminate nerve or nerve endings on the organ surface using LED meshes (Samineni et al. 2017a).”
BackgroundMethodKim, S., Kim, T., Kim, H., Kim, J., Rogers, J. A., & Hahn, S. K. (2024) · Advanced Materials · doi:10.1002/adma.202413189 · Cited by 12
Self-citationLynch, N. A., Luca, R. D., Spinieli, R. L., Rillosi, E., Thomas, R. C., Sailesh, S., Gangeddula, N., Lima, J. D., Bandaru, S. S., Arrigoni, E., et al. (2025) · Advanced Science · doi:10.1002/advs.202500325 · Cited by 12
Aetiology, pathogenesis and management of neuropathic itch: A narrative review with recent updates
Poddar, S., Mondal, H., & Podder, I. (2023) · Indian Journal of Dermatology Venereology and Leprology · doi:10.25259/ijdvl_846_2022 · Cited by 12
Assembly‐Type Wireless Communication Patch for Miniaturized Flexible Wearable Sensors
Song, M., Kang, S., Kim, J., & Kim, J. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202100034 · Cited by 13
Self-citationLee, J. Y., Kim, T., Cho, S., Shin, J. H., Yeo, W., Kim, T. S., & Yu, K. J. (2025) · Bioactive Materials · doi:10.1016/j.bioactmat.2025.02.006 · Cited by 11
“These attributes make μ -LEDs particularly well-suited for applications involving behavioral experiments in freely moving animals, where unrestricted movement and long-term stability are crucial [50 – 53].”
Kim, M., López‐Cano, M., Zhang, K., Wang, Y., Gómez‐Santacana, X., Flores, Á., Wu, M., Li, S., Zhang, H., Wei, Y., et al. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117440 · Cited by 11
Self-citationLaser Micromachining for Bioelectronics: Past, Present, and Future
Troughton, J. G., & Proctor, C. M. (2025) · Small Methods · doi:10.1002/smtd.202501560 · Cited by 10
Yu, Q., Yu, X., Zhou, H., Chen, F., Cheng, H., & Wu, H. (2019) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab10b0 · Cited by 10
Sánchez-Martín, M. D. M., Giraldo, E., Alastrue‐Agudo, A., Mocholi, E. L., Pérez, S. M., Mannino, L., Paniagua, G., Sánchez, A. I. F., Monreal-Trigo, J., Haro, J. M. T., et al. (2025) · Molecular Therapy · doi:10.1016/j.ymthe.2025.07.041 · Cited by 9
“Sustained BL stimulation was applied by the implanted μ LED device 17 immediately over the laminectomy area for 1 h/d for 4 weeks in awake rats.”
A HO-1 gene knockout using a NanoCRISPR scaffold suppresses metastasis in mouse models
Wang, N., Luo, Z., Liu, C., Ma, J., Wu, X., Wu, Q., Liu, X., & Gong, C. (2025) · Nature Biomedical Engineering · doi:10.1038/s41551-025-01518-1 · Cited by 9
“These approaches can overcome the limitations posed by the limited depth of light penetration through tissues, making AVAX more applicable for treating deep-seated tumours 3,65,66 .”
Survey of near-field wireless communication and power transfer for biomedical implants
Abduljaleel, H. K., Mutashar, S., & Gharghan, S. K. (2024) · Engineering and Technology Journal · doi:10.30684/etj.2024.144480.1636 · Cited by 9
Flexible and Soft Materials and Devices for Neural Interface
Castagnola, E., Zheng, X. S., & Cui, X. T. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_5-1 · Cited by 8
Implantable micro and nanophotonic devices: toward a new generation of neural interfaces
Pisanello, F. (2019) · Microelectronic Engineering · doi:10.1016/j.mee.2019.110979 · Cited by 8
Fang, X., Ding, H., Chen, Y., Wang, Q., Yuan, X., Zhang, C., Huang, J., Huang, J., Lv, J., Hu, H., et al. (2024) · Small Methods · doi:10.1002/smtd.202400216 · Cited by 7
Self-citationGonzalez, M., Gradwell, M. A., Thackray, J. K., Temkar, K. K., Patel, K., & Abraira, V. E. (2025) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2025.110495 · Cited by 7
Recent developments and future perspectives on neuroelectronic devices
Rinklin, P., & Wolfrum, B. L. (2021) · e-Neuroforum · doi:10.1515/nf-2021-0019 · Cited by 7
“Similar to electrical devices, optical technology was also advanced to reach wireless (Park et al., 2015; Samineni et al., 2017) or injectable (Kim et al., 2013; see Figure 5c) levels.”
BackgroundSingle-channel opto-neurostimulators: a review
Yang, W., Khan, W., Wu, J., & Li, W. (2019) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ab003d · Cited by 6
“Compared to farfield EM coupling, near-field EM power transfer relies on inductive coupling through pairs of antenna coils [40, 92] to sufficiently power the light sources at much lower frequencies (<135 MHz) [91] without surpassing the SAR limits.”
Background3D-printed optogenetic neural probe integrated with microfluidic tube for opsin/drug delivery
Sukesan, R., Mohammed, M., Oh, K., Sharma, M., Chaudhury, D., & Ha, S. (2025) · Scientific Reports · doi:10.1038/s41598-025-13654-4 · Cited by 5
“This microfabrication-based approach enables the utilization of various materials, such as silicon 21–23 , SU-8 24 , polyimide (PI) 25,26 and polyethylene terephthalate (PET) 27,28 to create highly customizable designs.”
The 2026 roadmap on wireless and microwave metasurfaces
Alomainy, A., Henthorn, S. D., Abbasi, Q. H., Burton, F. A., Walker, A., Zhang, Y., Kazim, J. U. R., Tahir, F. A., Imran, M. A., Baraclough, M., et al. (2026) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ae2b7c · Cited by 5
“Wireless technologies are essential for bioelectronic devices used in diagnostics and therapy, ranging from early pacemakers [96] to modern implants like cochlear [97] and retinal devices [98], health monitors, ingestible cameras [99], and spinal cord stimulators [100].”
From materials to systems: resonant inductive coupling for wireless bioelectronics
Kim, D., Joo, J., Kim, B., Park, Y., Won, S. M., & Yoo, J. (2026) · npj Flexible Electronics · doi:10.1038/s41528-026-00576-y · Cited by 4
“7,whenbenttoaradiusof5mm 31 .”
Gharabli, S. A., Al‐Rifai, N., Abu-samha, M., Alotaibi, S., & Kujawa, J. (2026) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2026.218079 · Cited by 4
Maruta, T., Hidaka, K., Kouroki, S., Koshida, T., Kurogi, M., Kage, Y., Mizuno, S., Shirasaka, T., Yanagita, T., Takahashi, S., et al. (2022) · PLoS ONE · doi:10.1371/journal.pone.0275751 · Cited by 4
Implantable LED for Optogenetics
Yang, Y., Vázquez‐Guardado, A., & Rogers, J. A. (2021) · Series in display science and technology · doi:10.1007/978-981-16-5505-0_6 · Cited by 4
Self-citationProspects of neuromodulation for chronic pain
Isagulyan, E. D., Mikhailova, V. A., Aslakhanova, K. S., & Slavin, K. V. (2021) · Brain Disorders · doi:10.1016/j.dscb.2021.100027 · Cited by 4
Kim, W. S., Hong, S., & Park, S. I. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629753 · Cited by 3
“These are linked to biological strains and/or mechanical stress due to natural motions of an animal (contortion of abdomen cavity, gastric distension) [11], [18,19].”
BackgroundIn Vivo Evaluation of Thermally Drawn Biodegradable Optical Fibers as Brain Implants
Abdollahiyan, P., Sui, K., Li, G., Wang, J., Zhang, C., Wang, Y., Berg, R. W., Meneghetti, M., & Markos, C. (2025) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.35549 · Cited by 3
Optogenetic modulation of peripheral nociceptive neurons with biocompatible optoelectronic implants
Chung, P. C. S., Paggi, V., Pertin, M., Kirschmann, G., Konnova, E. A., Michoud, F., Furfaro, I., Schneider, B. L., Lacour, S. P., & Décosterd, I. (2025) · Bioengineering & Translational Medicine · doi:10.1002/btm2.70034 · Cited by 2
“29 Significant improvements in the field have been made by the development of refined devices powered through miniaturized antennas 30,31 or Bluetooth-controlled headstage units.”
Wide Area Uniform Illumination Scheme Using LED Matrix for Optogenetic Cardiac Pacing
Izadi, I., Dusend, V., Takrouni, A., Nudds, N., Gradkowski, K., O'Brien, P. A., Sasse, P., & Corbett, B. (2021) · Photonics · doi:10.3390/photonics8110499 · Cited by 2
“…and prosthetics such as deep brain stimulation electrodes [6,7], retina implants [8,9], cochlear implants [10,11] and spinal cord injury implants [12] or early stage experiments for restoring function to permanently denervated muscles in motor neuron diseases such as Amyotrophic Lateral…”
Background
Metadata
- Authors
- Samineni, V. K., Yoon, J., Crawford, K. E., Jeong, Y. R., McKenzie, K. C., Shin, G., Xie, Z., Sundaram, S. S., Li, Y., Yang, M. Y., Kim, J., Wu, D., Xue, Y., Feng, X., Huang, Y., Mickle, A. D., Banks, A., Ha, J. S., Golden, J. P., Rogers, J. A., & Gereau, R. W.
- Affiliations
- Washington University in St. Louis (US)
- University of Illinois Urbana-Champaign (US)
- Korea University (KR)
- Northwestern University (US)
- Beihang University (CN)
- Tsinghua University (CN)
- Corresponding author
- Gereau, Robert W.
- ORCID
- Venue
- Pain
- Published
- 2017-06-08
- Volume
- 158
- Issue
- 11
- Pages
- 2108-2116
- ISSN
- 0304-3959 (ISSN-L)
- 1872-6623
- PMC
- PMC5640477
- OpenAlex
- W2735867997
- Semantic Scholar
- d4ca851f9aa32e0c8da2c891e485386750bf2117
- Cited by
- 119
- References
- 43
- Citations by year
- 2026: 8 · 2025: 17 · 2024: 6 · 2023: 5 · 2022: 15 · 2021: 25 · 2020: 11 · 2019: 19 · 2018: 12 · 2017: 1
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Pain (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (R01NS048602, R01NS081707, R01NS042595)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Photoreceptor and optogenetics research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Keywords
- wireless power transfer, battery-free devices, near-field wireless communication, dorsal horn, nocifensive behavior, place aversion, freely moving animals, spinal cord circuits, biocompatibility, device durability
- MeSH terms
- Animals, Calcium-Binding Proteins, Disease Models, Animal, Exploratory Behavior, Glial Fibrillary Acidic Protein, Locomotion, Male, Mice, Transgenic, Microfilament Proteins, Spinal Cord, Spinal Nerves, Wakefulness, Calcitonin Gene-Related Peptide, Green Fluorescent Proteins, TRPV Cation Channels, Mice, Electromagnetic Phenomena, Wireless Technology, Optogenetics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.