Influence of posture on routine hemostasis testing
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Biological variability is an important aspect for appropriate interpretation of hemostasis testing, but unreliable evidence has been provided to date regarding the effect of different postures on first-line clotting tests such as activated partial thromboplastin time (APTT), prothrombin time (PT) and fibrinogen. Variation of APTT, PT and fibrinogen was therefore investigated in 19 healthy volunteers after 25 min in supine position, 20 min in sitting position and 20 min stationary standing in upright position. The change from supine to sitting position caused a significant decrease of PT and a significant increase of fibrinogen. The variation of fibrinogen exceeded the quality specifications for bias. The change from supine to standing position caused a significant bias in all the parameters tested, with a decrease of PT and an increase of fibrinogen that exceeded the quality specifications for bias. The change from sitting to standing position also caused a significant bias in all the parameters tested, but none of these variations was greater than the quality specifications for bias. The results of this investigation show that patient posture may have a significant impact on results of routine hemostasis testing, especially when patient position is changed from supine to standing.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It has been shown that change of a body position from supine to upright and vice versa can dramatically affect the concentration of many laboratory parameters [16], [17], [18], [19].”
From Joint EFLM-COLABIOCLI Recommendation for venous blood sampling (2018) · cites this paper as [17]
Citations
Cites
Calculation of percentage changes in volumes of blood, plasma, and red cells in dehydration.
Dill, D. B., & Costill, D. L. (1974) · Journal of Applied Physiology · doi:10.1152/jappl.1974.37.2.247 · Cited by 3,384
Current databases on biological variation: pros, cons and progress
C. Ricós, V. A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185229 · Cited by 987
Congenital Fibrinogen Disorders: An Update
Casini, A., Neerman-Arbez, M., & de Moerloose, P. (2013) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0033-1349222 · Cited by 302
Plasma volume changes with movement to supine and standing positions
Hagan, R. D., Diaz, F. J., & Horvath, S. M. (1978) · Journal of Applied Physiology · doi:10.1152/jappl.1978.45.3.414 · Cited by 251
Quality Standards for Sample Collection in Coagulation Testing
Lippi, G., Salvagno, G., Montagnana, M., Lima-Oliveira, G., Guidi, G., & Favaloro, E. (2012) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0032-1315961 · Cited by 196
Self-citationQuality Standards for Sample Processing, Transportation, and Storage in Hemostasis Testing
Adcock Funk, D., Lippi, G., & Favaloro, E. (2012) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0032-1319768 · Cited by 144
Self-citationStatland, B. E., Bokelund, H., & Winkel, P. (1974) · Clinical Chemistry · doi:10.1093/clinchem/20.12.1513 · Cited by 96
Activated Partial Thromboplastin Time: New Tricks for an Old Dogma
Lippi, G., & Favaloro, E. (2008) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0028-1104539 · Cited by 82
Self-citationMarlar, R. A., Potts, R. M., & Marlar, A. A. (2006) · American Journal of Clinical Pathology · doi:10.1309/rrqkt2jeyv33d19d · Cited by 74
Preanalytical conditions that affect coagulation testing, including hormonal status and therapy
Blombäck, M., Konkle, B. A., Manco‐Johnson, M. J., Bremme, K. A., Hellgren, M., & Kaaja, R. (2007) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2007.02401.x · Cited by 55
Orthostatic Hypercoagulability
Masoud, M., Sarig, G., Brenner, B., & Jacob, G. (2008) · Hypertension · doi:10.1161/hypertensionaha.108.112003 · Cited by 54
Emergency room crowding: a marker of hospital health.
Barish, R. A., McGauly, P. L., & Arnold, T. (2012) · PubMed Central · Cited by 46
Posture and the composition of plasma.
Dixon, M., & Paterson, C. R. (1978) · Clinical Chemistry · doi:10.1093/clinchem/24.5.824 · Cited by 42
Effect of posture on the plasma cholesterol level.
Stoker, D., Wynn, V., & Robertson, G. (1966) · BMJ · doi:10.1136/bmj.1.5483.336 · Cited by 42
MILOS, M., HERAK, D., KURIC, L., HORVAT, I., & ZADRO, R. (2009) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2007.00999.x · Cited by 40
Biological Variation in Tests of Hemostasis
Banfi, G., & FABBRO, M. D. (2009) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0029-1214155 · Cited by 32
Chen, Q., Shou, W., Wu, W., Guo, Y., Zhang, Y., Huang, C., & Cui, W. (2015) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0034-1543994 · Cited by 29
Laboratory hemostasis: milestones in Clinical Chemistry and Laboratory Medicine
Lippi, G., & Favaloro, E. J. (2012) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0387 · Cited by 27
Self-citationInfluence of two different buffered sodium citrate concentrations on coagulation testing
Lippi, G., Salvagno, G. L., Montagnana, M., & Guidi, G. C. (2005) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000172097.15458.c5 · Cited by 15
Self-citationThe Feasibility and Impact of Midnight Routine Blood Draws on Laboratory Orders and Processing Time
Sorita, A., Patterson, A., Landazuri, P., De-Lin, S., Fischer, C., Husk, G. A., & Sivaprasad, L. (2014) · American Journal of Clinical Pathology · doi:10.1309/ajcppl8kfh3kfhnv · Cited by 11
Hydration does not prevent orthostatic hypercoagulability
Brenner, B., Masoud, M., Sarig, G., & Jacob, G. (2009) · Thrombosis and Haemostasis · doi:10.1160/th09-06-0370 · Cited by 11
Research works printed but not linked: 1
- Favaloro, 2010, Improving the harmonisation of the International Normalized Ratio (INR): Time to think outside the box Clin Chem Lab M, ed, 48, 1079
Cited by
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240
Self-citationLima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117
“Patient posture: patient should be kept in a standardized posture for 15–20min in order to reduce laboratory variability [32,34]; however, this might impact on the workflow of blood collection sites, but can be eased by scheduling blood collections; 4.”
BackgroundSelf-citationPhlebotomy, a bridge between laboratory and patient
Ialongo, C., & Bernardini, S. (2016) · Biochemia Medica · doi:10.11613/bm.2016.002 · Cited by 97
Kitchen, S., Adcock, D. M., Dauer, R., Kristoffersen, A., Lippi, G., Mackie, I. J., Marlar, R. A., & Nair, S. C. (2021) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13702 · Cited by 104
Self-citationMcDonald, S. J., Shultz, S. R., & Agoston, D. V. (2021) · Journal of Neurotrauma · doi:10.1089/neu.2021.0011 · Cited by 75
Metadata
- Authors
- Lippi, G., Salvagno, G. L., Lima-Oliveira, G., Danese, E., Favaloro, E. J., & Guidi, G. C.
- Affiliations
- University of Verona (IT)
- Westmead Hospital (AU)
- Corresponding author
- Lippi, Giuseppe
- ORCID
- Venue
- Blood Coagulation & Fibrinolysis
- Published
- 2015-09
- Volume
- 26
- Issue
- 6
- Pages
- 716-719
- ISSN
- 0957-5235 (ISSN-L)
- OpenAlex
- W2417011101
- Semantic Scholar
- 42499beffa69be47e3d464a874c185570b511ce8
- Cited by
- 27
- References
- 21
- Citations by year
- 2024: 1 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 4 · 2018: 5 · 2017: 5 · 2016: 6 · 2015: 1
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Blood Coagulation & Fibrinolysis (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Hematology › Blood properties and coagulation
- Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
- Keywords
- patient posture, hemostasis testing, activated partial thromboplastin time, prothrombin time, fibrinogen, supine position, sitting posture, standing posture, biological variation, assay bias, quality specifications
- MeSH terms
- Female, Hemostasis, Humans, Male, Posture
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.