Automatic quality assessment for 2D fetal sonographic standard plane based on multitask learning
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
The quality control of fetal sonographic (FS) images is essential for the correct biometric measurements and fetal anomaly diagnosis. However, quality control requires professional sonographers to perform and is often labor-intensive. To solve this problem, we propose an automatic image quality assessment scheme based on multitask learning to assist in FS image quality control. An essential criterion for FS image quality control is that all the essential anatomical structures in the section should appear full and remarkable with a clear boundary. Therefore, our scheme aims to identify those essential anatomical structures to judge whether an FS image is the standard image, which is achieved by 3 convolutional neural networks. The Feature Extraction Network aims to extract deep level features of FS images. Based on the extracted features, the Class Prediction Network determines whether the structure meets the standard and Region Proposal Network identifies its position. The scheme has been applied to 3 types of fetal sections, which are the head, abdominal, and heart. The experimental results show that our method can make a quality assessment of an FS image within less a second. Also, our method achieves competitive performance in both the segmentation and diagnosis compared with state-of-the-art methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Faster R-CNN: Towards Real-Time Object Detection with Region Proposal Networks
Ren, S., He, K., Girshick, R., & Sun, J. (2017) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2016.2577031 · Cited by 73,472
You Only Look Once: Unified, Real-Time Object Detection
Redmon, J., Divvala, S., Girshick, R., & Farhadi, A. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.91 · Cited by 53,803
Feature Pyramid Networks for Object Detection
Lin, T.-Y., Dollar, P., Girshick, R., He, K., Hariharan, B., & Belongie, S. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.106 · Cited by 30,939
A systematic analysis of performance measures for classification tasks
Sokolova, M., & Lapalme, G. (2009) · Information Processing & Management · doi:10.1016/j.ipm.2009.03.002 · Cited by 7,515
Relation Networks for Object Detection
Hu, H., Gu, J., Zhang, Z., Dai, J., & Wei, Y. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2018.00378 · Cited by 1,524
SonoNet: Real-Time Detection and Localisation of Fetal Standard Scan Planes in Freehand Ultrasound
Baumgartner, C. F., Kamnitsas, K., Matthew, J., Fletcher, T. P., Smith, S., Koch, L. M., Kainz, B., & Rueckert, D. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2712367 · Cited by 416
Multi-Scale Deep Reinforcement Learning for Real-Time 3D-Landmark Detection in CT Scans
Ghesu, F.-C., Georgescu, B., Zheng, Y., Grbic, S., Maier, A., Hornegger, J., & Comaniciu, D. (2019) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2017.2782687 · Cited by 310
FUIQA: Fetal Ultrasound Image Quality Assessment with Deep Convolutional Networks
Wu, L., Cheng, J.-Z., Li, S., Lei, B., Wang, T., & Ni, D. (2017) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2017.2671898 · Cited by 242 · cited 2×
“The proposed scheme achieved competitive performance in both view diagnosis and region localization.([18]) Chang et al([19]) proposed an automatic mid-sagittal plane (MSP) assessment method for categorizing the 3D fetal ultrasound images.”
MethodZhang, J., Liu, M., & Shen, D. (2017) · IEEE Transactions on Image Processing · doi:10.1109/tip.2017.2721106 · Cited by 192
Cited by
Use of artificial intelligence and deep learning in fetal ultrasound imaging
Ramirez Zegarra, R., & Ghi, T. (2023) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.26130 · Cited by 102
Nurmaini, S., Rachmatullah, M. N., Sapitri, A. I., Darmawahyuni, A., Tutuko, B., Firdaus, F., Partan, R. U., & Bernolian, N. (2021) · Sensors · doi:10.3390/s21238007 · Cited by 81
Sakai, A., Komatsu, M., Komatsu, R., Matsuoka, R., Yasutomi, S., Dozen, A., Shozu, K., Arakaki, T., Machino, H., Asada, K., et al. (2022) · Biomedicines · doi:10.3390/biomedicines10030551 · Cited by 68
Jost, E., Kosian, P., Jimenez Cruz, J., Albarqouni, S., Gembruch, U., Strizek, B., & Recker, F. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12216833 · Cited by 44
“Zhang et al. proposed an image quality assessment method for evaluating whether US images of standard planes fully show the anatomical structures with clear boundaries [29].”
Method
Metadata
- Authors
- Zhang, B., Liu, H., Luo, H., & Li, K.
- Venue
- Medicine
- Published
- 2021-01-29
- Volume
- 100
- Issue
- 4
- Pages
- e24427
- ISSN
- 0025-7974 (ISSN-L)
- 1536-5964
- OpenAlex
- W3127641755
- Cited by
- 61
- References
- 12
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic quality assessment for 2D fetal sonographic standard plane based on multitask learning. https://app.cochat.ai/papers/10.1097/md.0000000000024427
- The paper
- Zhang, B., Liu, H., Luo, H., & Li, K. (2021). Automatic quality assessment for 2D fetal sonographic standard plane based on multitask learning. Medicine. https://doi.org/10.1097/md.0000000000024427
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.