Postmortem Magnetic Resonance Imaging to Guide the Pathologic Cut: Individualized, 3-Dimensionally Printed Cutting Boxes for Fixed Brains
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Interfacing magnetic resonance imaging (MRI) with pathology is critically important for understanding the pathologic basis of MRI signal changes in vivo and for clinicopathologic correlations. Postmortem MRI is an intermediate step in this process; unfortunately, however, relating the data to standard pathologic sections, which are relatively thick and often nonparallel, is both time-consuming and insufficiently accurate. The aim of this project was to develop technology to integrate postmortem, high-resolution, whole-brain MRI into the planning and execution of pathologic analysis through precise localization of the target and coordinates of cut. Compared with standard pathologic sectioning, the use of an individualized, 3-dimensionally printed cutting box-designed based on postmortem MRI of formalin-fixed whole brains-improved the speed, quality, and accuracy of radiologic-pathologic correlations and, specifically, the histopathologic localization of imaging findings. The technology described herein is easily implemented, applicable to any brain disorder, and potentially extendable to other organs. From the point of view of the pathologist, this technique can improve localization of small or subtle abnormalities, whereas from the point of view of the radiologist, it has the potential to improve understanding of MRI signal changes observed in diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortical lesions in multiple sclerosis
Kidd, D., Barkhof, F., McConnell, R., Algra, P. R., Allen, I. V., & Revesz, T. (1999) · Brain · doi:10.1093/brain/122.1.17 · Cited by 766 · cited 1×
“This lesion can be classified as a type 3 subpial cortical lesion (18).”
Diffusion tensor imaging of post mortem multiple sclerosis brain
Schmierer, K., Wheeler-Kingshott, C. A. M., Boulby, P. A., Scaravilli, F., Altmann, D. R., Barker, G. J., Tofts, P. S., & Miller, D. H. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.12.010 · Cited by 395 · cited 1×
“Conventional studies of MRI-pathology correlations involve imaging slices of tissue after the initial cutting of the brain (1, 3, 5, 19, 21, 26).”
Quantitative magnetic resonance of postmortem multiple sclerosis brain before and after fixation
Schmierer, K., Wheeler‐Kingshott, C. A. M., Tozer, D. J., Boulby, P. A., Parkes, H. G., Yousry, T. A., Scaravilli, F., Barker, G. J., Tofts, P. S., & Miller, D. H. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21487 · Cited by 281
Postmortem MRI of human brain hemispheres: T 2 relaxation times during formaldehyde fixation
Dawe, R. J., Bennett, D. A., Schneider, J. A., Vasireddi, S. K., & Arfanakis, K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21909 · Cited by 162
Schmierer, K., Scaravilli, F., Barker, G. J., Gordon, R., MacManus, D. G., & Miller, D. H. (2003) · Neuropathology and Applied Neurobiology · doi:10.1046/j.0305-1846.2003.00497.x · Cited by 35 · cited 1×
“Postmortem MRI acquisition of fixed brain tissue is useful because it provides a more detailed view of brain structures and identifies minute findings that may have been missed in vivo; thus, it may facilitate better MRI-neuropathology analysis for clinical-pathologic correlations (8, 19).”
Cited by
A lymphocyte–microglia–astrocyte axis in chronic active multiple sclerosis
Absinta, M., Maric, D., Gharagozloo, M., Garton, T., Smith, M. D., Jin, J., Fitzgerald, K. C., Song, A., Liu, P., Lin, J.-P., et al. (2021) · Nature · doi:10.1038/s41586-021-03892-7 · Cited by 768
Self-citationAbsinta, M., Ha, S.-K., Nair, G., Sati, P., Luciano, N. J., Palisoc, M., Louveau, A., Zaghloul, K. A., Pittaluga, S., Kipnis, J., et al. (2017) · eLife · doi:10.7554/elife.29738 · Cited by 643
Association of Chronic Active Multiple Sclerosis Lesions With Disability In Vivo
Absinta, M., Sati, P., Masuzzo, F., Nair, G., Sethi, V., Kolb, H., Ohayon, J., Wu, T., Cortese, I. C. M., & Reich, D. S. (2019) · JAMA Neurology · doi:10.1001/jamaneurol.2019.2399 · Cited by 534
Self-citationPersistent 7-tesla phase rim predicts poor outcome in new multiple sclerosis patient lesions
Absinta, M., Sati, P., Schindler, M., Leibovitch, E. C., Ohayon, J., Wu, T., Meani, A., Filippi, M., Jacobson, S., Cortese, I. C. M., et al. (2016) · Journal of Clinical Investigation · doi:10.1172/jci86198 · Cited by 327
“individualized, MRI-designed, 3D-printed cutting box (53).”
Self-citationGadolinium-based MRI characterization of leptomeningeal inflammation in multiple sclerosis
Absinta, M., Vuolo, L., Rao, A., Nair, G., Sati, P., Cortese, I. C. M., Ohayon, J., Fenton, K., Reyes-Mantilla, M. I., Maric, D., et al. (2015) · Neurology · doi:10.1212/wnl.0000000000001587 · Cited by 296
Self-citation
Metadata
- Authors
- Absinta, M., Nair, G., Filippi, M., Ray-Chaudhury, A., Reyes-Mantilla, M. I., Pardo, C. A., & Reich, D. S.
- Venue
- Journal of Neuropathology & Experimental Neurology
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-08
- Volume
- 73
- Issue
- 8
- Pages
- 780-788
- ISSN
- 0022-3069 (ISSN-L)
- 1554-6578
- OpenAlex
- W2331109341
- Cited by
- 73
- References
- 5
- FWCI
- 2.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Postmortem Magnetic Resonance Imaging to Guide the Pathologic Cut: Individualized, 3-Dimensionally Printed Cutting Boxes for Fixed Brains. https://app.cochat.ai/papers/10.1097/nen.0000000000000096
- The paper
- Absinta, M., Nair, G., Filippi, M., Ray-Chaudhury, A., Reyes-Mantilla, M. I., Pardo, C. A., & Reich, D. S. (2014). Postmortem Magnetic Resonance Imaging to Guide the Pathologic Cut: Individualized, 3-Dimensionally Printed Cutting Boxes for Fixed Brains. Journal of Neuropathology & Experimental Neurology. https://doi.org/10.1097/nen.0000000000000096
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.