Diurnal Variation of Corneal Shape and Thickness
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
PURPOSE: To investigate associations between the diurnal variation in a range of corneal parameters, including anterior and posterior corneal topography, and regional corneal thickness. METHODS: Fifteen subjects had their corneas measured using a rotating Scheimpflug camera (Pentacam) every 3 to 7 h over a 24-h period. Anterior and posterior corneal axial curvature, pachymetry and anterior chamber depth were analyzed. The best fitting corneal sphero-cylinder from the axial curvature, and the average corneal thickness for a series of different corneal regions were calculated. Measures of intraocular pressure and axial length were also taken at each measurement session. RESULTS: Significant diurnal variation was found to occur in both the anterior and posterior corneal curvature and in the regional corneal thickness. Flattening of the anterior corneal best sphere was observed at the early morning measurement upon waking (p < 0.0001). The posterior cornea also underwent a significant steepening (p < 0.0001) and change in astigmatism 90/180 degrees at this time. A significant swelling of the cornea (p < 0.0001) was also evident upon waking. Highly significant associations were found between the diurnal variation in corneal thickness and the changes in corneal curvature. CONCLUSIONS: Small but significant diurnal variation occurs in the regional thickness and the shape of the anterior and posterior cornea. The largest changes in the cornea are typically evident upon waking. The regional corneal swelling observed at this time was not uniform, being slightly greater in peripheral corneal regions. The pattern of corneal swelling evident on waking resulted in a steepening of the posterior, and a flattening of the anterior corneal surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thibos, L. N., WHEELER, W., & Horner, D. G. (1997) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1997.tb04707.x · Cited by 1,238
Bland, J. M., & Altman, D. G. (1995) · BMJ · doi:10.1136/bmj.310.6977.446 · Cited by 1,034
Ambrósio, R., Alonso, R. S., Luz, A., & Coca Velarde, L. G. (2006) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2006.06.025 · Cited by 451
The specific architecture of the anterior stroma accounts for maintenance of corneal curvature
Muller, L. J. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.4.437 · Cited by 424
The shape of the anterior and posterior surface of the aging human cornea
Dubbelman, M., Sicam, V. A. D. P., & Van der Heijde, G. L. (2006) · Vision Research · doi:10.1016/j.visres.2005.09.021 · Cited by 378
LACKNER, B., SCHMIDINGER, G., PIEH, S., FUNOVICS, M. A., & SKORPIK, C. (2005) · Optometry and Vision Science · doi:10.1097/01.opx.0000180817.46312.0a · Cited by 311
Barkana, Y., Gerber, Y., Elbaz, U., Schwartz, S., Ken-Dror, G., Avni, I., & Zadok, D. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2005.03.058 · Cited by 298
A new non-contact optical device for ocular biometry
Santodomingo-Rubido, J. (2002) · British Journal of Ophthalmology · doi:10.1136/bjo.86.4.458 · Cited by 294
Shankar, H., Taranath, D., Santhirathelagan, C. T., & Pesudovs, K. (2008) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2007.09.013 · Cited by 286
Comparison of Dynamic Contour Tonometry with Goldmann Applanation Tonometry
Kaufmann, C., Bachmann, L. M., & Thiel, M. A. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0018 · Cited by 281 · cited 1×
“The DCT has been found to exhibit good inter- and intra-observer repeatability, comparable to Goldmann applanation tonometry.(50) The tonometer’s calibration was checked using the Pascal tonometer performance test kit before commencement of the study.”
MethodDiurnal variations in human corneal thickness.
Harper, C., Boulton, M., BENNETT, D. B., Marcyniuk, B., Jarvis-Evans, J., Tullo, A. B., & Ridgway, A. E. A. (1996) · British Journal of Ophthalmology · doi:10.1136/bjo.80.12.1068 · Cited by 259
Corneal swelling response to contact lenses worn under extended wear conditions.
Holden, B. A., Mertz, G. W., & McNally, J. J. (1983) · PubMed · Cited by 219
Dynamic Contour Tonometry: Presentation of a New Tonometer
Kanngiesser, H. E., Kniestedt, C., & Robert, Y. C. A. (2005) · Journal of Glaucoma · doi:10.1097/01.ijg.0000176936.16015.4e · Cited by 218
Boote, C., Dennis, S., Newton, R. H., Puri, H., & Meek, K. M. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0131 · Cited by 209 · cited 2×
“Boote et al.85 using X-ray diffraction techniques found that while the diameter of stromal collagen fibrils remained constant from center to the periphery, the fibril spacing was greater in the peripheral cornea.”
MethodDiurnal Variation of Corneal Sensitivity and Thickness
du Toit, R., Vega, J. A., Fonn, D., & Simpson, T. (2003) · Cornea · doi:10.1097/00003226-200304000-00004 · Cited by 197
Feng, Y., Varikooty, J., & SIMPSON, T. L. (2001) · Cornea · doi:10.1097/00003226-200107000-00008 · Cited by 195
Kotecha, A. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.075580 · Cited by 184
Diurnal Variation of Axial Length, Intraocular Pressure, and Anterior Eye Biometrics
Read, S. A., Collins, M. J., & Iskander, D. R. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-1833 · Cited by 173 · cited 3×
“Upon first waking, we found a flattening of the anterior corneal surface, a steepening of the posterior corneal surface, a thickening of the cornea (of slightly greater magnitude in the peripheral cornea) and a concomitant reduction in the ACD.76 The pattern of corneal and anterior chamber change observed upon first w…”
BackgroundInfluentialSelf-citationChen, D., & Lam, A. K. C. (2007) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2006.11.008 · Cited by 157
Schneider, E., & Grehn, F. J. (2005) · Journal of Glaucoma · doi:10.1097/01.ijg.0000196655.85460.d6 · Cited by 150
Lam, A. K. C., Chan, R., & Pang, P. C. K. (2001) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.2001.00611.x · Cited by 147
Validity and Repeatability of Anterior Chamber Depth Measurements With Pentacam and Orbscan
Lackner, B., Schmidinger, G., & Skorpik, C. (2005) · Optometry and Vision Science · doi:10.1097/01.opx.0000177804.53192.15 · Cited by 147
Overnight swelling of the living human cornea.
Mertz, G. W. (1980) · PubMed · Cited by 142
Ocular Component Measurement Using the Zeiss IOLMaster
Sheng, H., Bottjer, C., & Bullimore, M. A. (2004) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2004.tb02848.x · Cited by 134
Determination of Corneal Image-forming Properties from Corneal Topography
Maloney, R. K., Bogan, S., & Waring, G. O., IV (1993) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)73521-4 · Cited by 126 · cited 2×
“The best fit corneal sphero-cylinder was then calculated for each of the axial power maps for each subject at each session using the methods of Maloney et al.(73) for a 3.”
MethodInfluentialWater gradients across bovine cornea.
Castoro, J. A., Bettelheim, A. A., & Bettelheim, F. A. (1988) · PubMed · Cited by 111
Wang, J., Fonn, D., & SIMPSON, T. L. (2001) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2001.tb03609.x · Cited by 102
Keratoconus Detection Based on Videokeratoscopic Height Data
Schwiegerling, J. T., & Greivenkamp, J. E. (1996) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1996.tb04555.x · Cited by 87
Bergmanson, J. P. G., Horne, J., Doughty, M. J., Garcia, M., & Gondo, M. (2005) · Eye & Contact Lens: Science & Clinical Practice · doi:10.1097/01.icl.0000165280.94927.0d · Cited by 75
Avitabile, T., Marano, F., Uva, M. G., & REIBALDI, A. (1997) · Cornea · doi:10.1097/00003226-199711000-00007 · Cited by 74
Non-uniform swelling properties of the corneal stroma
Lee, D., & Wilson, G. (1981) · Current Eye Research · doi:10.3109/02713688109019986 · Cited by 72 · cited 1×
“The swelling properties of the anterior and posterior stroma have also been found to differ.(78,80) Differential swelling between the anterior and posterior corneal stroma may therefore account for some of the differences we have observed in the diurnal variation in the curvature of the anterior and posterior corneal…”
BackgroundUneven swelling of the corneal stroma.
Kikkawa, Y., & Hirayama, K. (1970) · PubMed · Cited by 67
Schneider, E., Kanngiesser, H. E., & Kniestedt, C. (2006) · Springer eBooks · doi:10.1007/3-540-34773-9_3 · Cited by 66
The Diurnal Variation of Corneal Topography and Aberrations
Read, S. A., Collins, M. J., & Carney, L. G. (2005) · Cornea · doi:10.1097/01.ico.0000154385.43732.6e · Cited by 65
Self-citationAvitabile, T., Marano, F., Uva, M. G., & REIBALDI, A. (1997) · PubMed · Cited by 62
Evaluation of biometric methods for measuring the anterior chamber depth in the non-contact mode
Meinhardt, B., Stachs, O., Stave, J., Beck, R., & Guthoff, R. F. (2005) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-005-0103-7 · Cited by 60
Moezzi, A., Fonn, D., SIMPSON, T. L., & Sorbara, L. (2004) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2004.tb01909.x · Cited by 55
Measurement of Corneal Swelling Variations without Removal of the Contact Lens during Extended Wear
Martín, R., de Juan, V., ́guez, G. R., Cuadrado, R., & Fernández, I. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-1372 · Cited by 48
Owens, H., & Watters, G. A. (1996) · Ophthalmic and Physiological Optics · doi:10.1016/0275-5408(95)00017-8 · Cited by 48
Holden, B. A., Mcnally, J. J., Mertz, G. W., & Swarbrick, H. A. (1985) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1985.tb01581.x · Cited by 47
Central and Peripheral Corneal Swelling Accompanying Soft Lens Extended Wear
Bonanno, J. A., & Polse, K. A. (1985) · Optometry and Vision Science · doi:10.1097/00006324-198502000-00002 · Cited by 47
Kamiya, K., Miyata, K., Tokunaga, T., Kiuchi, T., Hiraoka, T., & Oshika, T. (2004) · Cornea · doi:10.1097/01.ico.0000136673.35530.e3 · Cited by 41
Effects of Hydrogel Lens Transmissibility Profiles on Local Corneal Swelling During Eye Closure
Erickson, P. A., Comstock, T. L., & Zantos, S. G. (1996) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1996.tb04434.x · Cited by 22
Should Orbscan pachometry be performed before or after Goldmann applanation tonometry?
Huang, R. Y. C., Lam, A. K. C., Chan, R., & Young, S. (2005) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2005.00321.x · Cited by 8
Cited by
Diurnal Variations in Axial Length, Choroidal Thickness, Intraocular Pressure, and Ocular Biometrics
Chakraborty, R., Read, S. A., & Collins, M. J. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-7364 · Cited by 499
Self-citationCorneal Deformation Measurement Using Scheimpflug Noncontact Tonometry
Hon, Y., & Lam, A. K. C. (2013) · Optometry and Vision Science · doi:10.1097/opx.0b013e318279eb87 · Cited by 235
“It is well supported that diurnal variation exists for corneal thickness.(23,24) Increased corneal thickness (both central and peripheral) is shown immediately after waking because of overnight corneal swelling of approximately 2.”
Background
Metadata
- Authors
- Read, S. A., & Collins, M. J.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2009-03
- Volume
- 86
- Issue
- 3
- Pages
- 170-180
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2048829657
- Cited by
- 182
- References
- 44
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.