CoChat

Scoring of Progressive Power Lenses by Means of User Power Maps

Arroyo, Rubén, Crespo, Daniel, Alonso, José · 2012 · Optometry and Vision Science
Cited by 37

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

PURPOSE: A progressive power lens (PPL) has a relatively complex power distribution, with regions for far, intermediate, and near vision, and also regions affected by aberrations, mainly astigmatism and defocus. Scoring techniques (Sheedy, Optom Vis Sci 2004;81:350-61) have been proposed to mark and classify PPLs according to their optical performance at each region. The objective of this study is to show that although scoring is useful to compare different lens designs, its outcome is highly dependent on the way power is defined and/or computed. METHODS: To demonstrate this, the progressive surfaces of many different current designs have been measured with a profiler. From these measurements and by means of exact ray tracing techniques, we obtain both the power maps that we would measure with a focimeter or a typical lens mapper and the power maps that the user perceives at the actual position of use. The scoring technique from Sheedy has then been applied to both types of maps. RESULTS: It is shown that the parameters that define the characteristics of a PPL when the power map is measured with a standard mapper are not significantly associated with the actual performance of the lens when it is fitted. In a similar way, it is shown that two lenses that have been optimized according to the same target power distribution may get completely different marks depending on the definition of power that has been used in the optimization process. We also propose a graphical method to easily grasp the overall PPL performance by simultaneously presenting four-dimensional information from the scoring technique. CONCLUSIONS: Although in general Sheedy's test is an important tool to compare different PPL designs, it cannot be used to compare those designs optimized for improving user power from classical front side designs when power has been measured for both types of designs with a standard focimeter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/opx.0b013e31824c16fa

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 37

Metadata

Authors
Arroyo, R., Crespo, D., & Alonso, J.
Venue
Optometry and Vision Science
Publisher
Wiley
Published
2012-04
Volume
89
Issue
4
Pages
E489-E501
ISSN
1040-5488 (ISSN-L)
OpenAlex
W2005934429
Cited by
37
References
6
FWCI
0.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Scoring of Progressive Power Lenses by Means of User Power Maps. https://app.cochat.ai/papers/10.1097/opx.0b013e31824c16fa
The paper
Arroyo, R., Crespo, D., & Alonso, J. (2012). Scoring of Progressive Power Lenses by Means of User Power Maps. Optometry and Vision Science. https://doi.org/10.1097/opx.0b013e31824c16fa

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.