Assessment of cardiac output in children: A comparison between the pressure recording analytical method and Doppler echocardiography*
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess cardiac output in pediatric patients with the pressure recording analytical method (PRAM) and the Doppler echocardiography method. PRAM derives cardiac output from beat-by-beat analysis of the arterial pressure profile (systolic and diastolic phase) in the time domain. DESIGN: A prospective observational study. SETTING: Pediatric intensive care unit at a tertiary care children's hospital. PATIENTS: Forty-eight patients between the ages of 1 month and 18 yrs. INTERVENTIONS: Femoral or radial artery catheterization and mechanical ventilation. MEASUREMENTS AND MAIN RESULTS: Cardiac output was simultaneously estimated by Doppler echocardiography and PRAM. Cardiac output values obtained by Doppler echocardiography (2.7 +/- 1.6 L/min, range 0.92-8.20) were significantly correlated with those estimated by PRAM (2.6 +/- 1.7 L/min, range 0.89-7.48; r2 = .99, p < .01). The mean difference between the two estimates was 0.12 +/- 0.27 L x min(-1) (95% confidence interval, -0.54 to 0.77 L x min(-1)). CONCLUSIONS: In the range of ages evaluated, PRAM provides reliable estimates of cardiac output when compared with noninvasive techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Clinicians’ abilities to estimate cardiac index in ventilated children and infants
Tibby, S. M., Hatherill, M., Marsh, M. J., & Murdoch, I. A. (1997) · Archives of Disease in Childhood · doi:10.1136/adc.77.6.516 · Cited by 224 · cited 1×
“Hemodynamic monitoring is fundamental to the management of the critically ill pediatric patient, but clinical estimation of cardiac output (CO) in children has been shown to be inaccurate (1).”
BackgroundChew, M. S., & Poelaert, J. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1967-9 · Cited by 151
Cited by
Noninvasive Cardiac Output Monitors: A State-of the-Art Review
Marik, P. E. (2013) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2012.03.022 · Cited by 293
New technologies in pediatric anesthesia
Holtby, H., Skowno, J. J., Kor, D. J., Flick, R. P., & Uezono, S. (2012) · Pediatric Anesthesia · doi:10.1111/pan.12007 · Cited by 35
Advanced Hemodynamic Monitoring in the Neonatal Intensive Care Unit
de Boode, W.-P. (2020) · Clinics in Perinatology · doi:10.1016/j.clp.2020.05.001 · Cited by 34
“There is an acceptable agreement from APCA (Pressure recording analytical method; MostCareUp, Vitec/Vigon, Padova, Italy) with TTE and the Fick method with an error percentage of 24 and 17, respectively.(34,36)”
MethodThe Gold Standard of Pediatric Hemodynamic Monitoring: Not All That Glitters Is Gold
Ricci, Z., Iacobelli, R., & Romagnoli, S. (2023) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000006215 · Cited by 4
Metadata
- Authors
- Calamandrei, M., Mirabile, L., Muschetta, S., Gensini, G. F., De Simone, L., & Romano, S. M.
- Venue
- Pediatric Critical Care Medicine
- Published
- 2008-05
- Volume
- 9
- Issue
- 3
- Pages
- 310-312
- ISSN
- 1529-7535 (ISSN-L)
- OpenAlex
- W2074166669
- Cited by
- 67
- References
- 3
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.