CoChat

Point-of-Care Echocardiography by Pediatric Emergency Physicians

Longjohn, Mindy, Wan, Jim, Joshi, Vijay, Pershad, Jay · 2011 · Pediatric Emergency Care
Cited by 106

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Currently, pediatric emergency medicine (PEM) physicians have limited data on point-of-care echocardiography (POCE). Our goals were to (1) determine the overall accuracy of POCE by PEMs in assessing left ventricular (LV) systolic function visually, presence or absence of pericardial effusion, and cardiac preload by estimating inferior vena cava (IVC) collapsibility, in acutely ill children in the pediatric emergency department; and (2) assess interobserver agreement between the PEM physician and pediatric cardiologist. METHODS: This is a prospective, observational study conducted in an urban, tertiary pediatric facility with an annual census of 67,000 emergency department visits. Patients between the ages of 0 and 18 years meeting 1 or more of the following inclusion criteria were recruited: (1) cardiopulmonary arrest, (2) fluid refractory shock requiring vasoactive infusions, (3) undifferentiated cardiomegaly on chest radiography, and (4) receiving emergent formal echocardiography. All eligible patients underwent POCE by 1 of 2 trained PEM physicians. Dynamic video clips were recorded and reviewed by a pediatric cardiologist who was unaware of the clinical condition of the study patients. RESULTS: For a period of 18 months, we recruited 70 patients. Diminished LV function was noted in 17, pericardial effusion in 16, and abnormal IVC collapsibility in 35 patients. The κ statistics of agreement between the PEM and the cardiologist for detection of LV function, IVC collapsibility, and effusion were 0.87 (95% confidence interval [CI], 0.73-1.00), 0.73 (95% CI, 0.59-0.88), and 0.77 (95% CI, 0.58-0.95), respectively. The overall sensitivity and specificity of POCE compared with a formal echocardiogram was 95% (95% CI, 82%-99%) and 83% (95% CI, 64%-93%), respectively. CONCLUSIONS: With goal-directed training, PEM physicians may be able to perform POCE and accurately assess for significant LV systolic dysfunction, vascular filling, and the presence of pericardial effusion. The model may be expanded to train physicians to use POCE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/pec.0b013e318226c7c7

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 106

Metadata

Authors
Longjohn, M., Wan, J., Joshi, V., & Pershad, J.
Venue
Pediatric Emergency Care
Published
2011-08
Volume
27
Issue
8
Pages
693-696
ISSN
0749-5161 (ISSN-L)
OpenAlex
W2078428169
Cited by
106
References
2
FWCI
4.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Point-of-Care Echocardiography by Pediatric Emergency Physicians. https://app.cochat.ai/papers/10.1097/pec.0b013e318226c7c7
The paper
Longjohn, M., Wan, J., Joshi, V., & Pershad, J. (2011). Point-of-Care Echocardiography by Pediatric Emergency Physicians. Pediatric Emergency Care. https://doi.org/10.1097/pec.0b013e318226c7c7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.