A Randomized Controlled Trial of Secondary Prevention of Anxiety and Distress in a German Sample of Patients With an Implantable Cardioverter Defibrillator
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Objective: To evaluate a minimal, easy, accessible intervention targeting anxiety and reduced quality of life in patients with an implantable cardioverter defibrillator (ICD). An estimated 24% to 87% of patients experience anxiety, and 10% to 15% have reduced quality of life. Methods: A total of 119 ICD patients were assigned randomly to usual medical aftercare (n = 63) or additional psychological treatment (n = 56) comprising of written information on medical and psychological consequences of an ICD plus 6 months of individual phone counseling. Treatment efficacy was evaluated by comparing T0 (immediately after implantation) and T1 (6 months later) assessments. Results: Although 75% of patients considered the program helpful, age moderated treatment efficacy. As indicated by triple interactions, only in the treatment group, anxiety (HADS-Anxiety, p < .01), psychological distress (SCL-K-9, p < .02), and somatic quality of life (SF-36-PCS, p < .01) improved in ICD patients aged <65 years but deteriorated in older patients (age, 65–75 years). Frequency of ICD discharges was associated with a symptom increase from T0 to T1 in all patients (HADS-Depression, CAQ-Avoidance, and ICD-Constraints; all p < .05). Conclusions: Our findings confirm that psychological treatments cannot be expected to have uniformly positive effects in ICD patients. Our minimal intervention may have adequately addressed ICD-related concerns in younger patients but may have fostered problems in older patients with fewer concerns. Therefore, our findings warrant custom treatment with particular attention to the elderly as well as patients with frequent ICD discharges. ANOVA = analysis of variance; ATP = antitachycardia pacing; BMI = body mass index; CAQ = Cardiac Anxiety Questionnaire; HADS = Hospital Anxiety and Depression Scale; ICD = implantable cardioverter defibrillator; MI = myocardial infarction; MANOVA = multivariate analysis of variance; QoL = quality of life; SCL-K-9 = Symptom Checklist, 9-item short form; SF-36-MCS = Medical Outcome Study Short Form-36 Health Survey: mental component summary; SF-36-PCS = Medical Outcome Study Short Form-36 Health Survey: physical component summary; T0 = assessment immediately after ICD implantation; T1 = assessment at the end of the intervention (i.e., 6 months later).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Depression as a risk factor for mortality in patients with coronary heart disease: a meta-analysis
Barth, J., Schumacher, M., & Herrmann-Lingen, C. (2004) · Psychosomatic Medicine · doi:10.1097/01.psy.0000146332.53619.b2 · Cited by 1,358
The Cardiac Anxiety Questionnaire: development and preliminary validity
Eifert, G. H., Thompson, R. N., Zvolensky, M. J., Edwards, K., Frazer, N. L., Haddad, J. W., & Davig, J. (2000) · Behaviour Research and Therapy · doi:10.1016/s0005-7967(99)00132-1 · Cited by 349 · cited 1×
“The subscale CAQ-Avoidance is best supported in the German version, but all subscales offer good reliability and convergent validity (49,50).”
BackgroundAn updated review of implantable cardioverter/defibrillators, induced anxiety, and quality of life.
Bostwick, J. M., & Sola, C. L. (2007) · Psychiatric Clinics of North America · doi:10.1016/j.psc.2007.07.002 · Cited by 101
Heart-focused anxiety before and after cardiac surgery
Hoyer, J., Eifert, G. H., Einsle, F., Zimmermann, K., Krauss, S., Knaut, M., Matschke, K., & Köllner, V. (2008) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2007.09.009 · Cited by 97 · cited 2×
“One study (51) indicated that sensitivity to change is high for CAQ-Fear, moderate for CAQ-Avoidance, and rather low for CAQ-Attention before versus after cardiac surgery.”
BackgroundGodemann, F., Butter, C., Lampe, F., Linden, M., Werner, S., & Behrens, S. (2004) · Quality of Life Research · doi:10.1023/b:qure.0000018493.32844.56 · Cited by 81
Cited by
Magyar-Russell, G., Thombs, B. D., Cai, J. X., Baveja, T., Kuhl, E. A., Singh, P. P., Montenegro Braga Barroso, M., Arthurs, E., Roseman, M., Amin, N., et al. (2011) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2011.02.014 · Cited by 267
Dunbar, S. B., Dougherty, C. M., Sears, S. F., Carroll, D. L., Goldstein, N. E., Mark, D. B., McDaniel, G., Pressler, S. J., Schron, E., Wang, P., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31825d59fd · Cited by 221
Irvine, J., Firestone, J., Ong, L., Cribbie, R., Dorian, P., Harris, L., Ritvo, P., Katz, J., Newman, D., Cameron, D., et al. (2011) · Psychosomatic Medicine · doi:10.1097/psy.0b013e31820afc63 · Cited by 103
LANG, S., BECKER, R., WILKE, S., HARTMANN, M., HERZOG, W., & LÖWE, B. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12276 · Cited by 36
Schulz, S. M., Ritter, O., Zniva, R., Nordbeck, P., Wacker, C., Jack, M., Groschup, G., Deneke, T., Puppe, F., Ertl, G., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz134 · Cited by 35
Self-citation
Metadata
- Authors
- Crössmann, A., Schulz, S. M., Kühlkamp, V., Ritter, O., Neuser, H., Schumacher, B., Bauer, W., & Pauli, P.
- Venue
- Psychosomatic Medicine
- Published
- 2010-06
- Volume
- 72
- Issue
- 5
- Pages
- 434-441
- ISSN
- 0033-3174 (ISSN-L)
- OpenAlex
- W1982256184
- Cited by
- 55
- References
- 6
- FWCI
- 5.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Randomized Controlled Trial of Secondary Prevention of Anxiety and Distress in a German Sample of Patients With an Implantable Cardioverter Defibrillator. https://app.cochat.ai/papers/10.1097/psy.0b013e3181d9bcec
- The paper
- Crössmann, A., Schulz, S. M., Kühlkamp, V., Ritter, O., Neuser, H., Schumacher, B., Bauer, W., & Pauli, P. (2010). A Randomized Controlled Trial of Secondary Prevention of Anxiety and Distress in a German Sample of Patients With an Implantable Cardioverter Defibrillator. Psychosomatic Medicine. https://doi.org/10.1097/psy.0b013e3181d9bcec
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.