CoChat

Comparison of Coronary Artery Calcium Scores Between Electron Beam Computed Tomography and 64-Multidetector Computed Tomographic Scanner

Mao, Song S., Pal, Raveen S., McKay, Charles R., Gao, Yan G., Gopal, Ambarish, Ahmadi, Naser, Child, Janis, Carson, Sivi, Takasu, Junichiro, Sarlak, Behnaz, Bechmann, Daniel, Budoff, Matthew Jay · 2009 · Journal of Computer Assisted Tomography
Cited by 110

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Because almost all data currently available with coronary calcium scanning are from electron beam tomography (EBT), we assessed whether scores obtained with 64-multidetector computed tomography (CT; MDCT) are similar. We evaluated the interscan variation in coronary artery calcium (CAC), Agatston score (AS), and volume score (VS) between EBT and 64-MDCT (VCT; GE, Milwaukee, Wis). MATERIALS AND METHODS: One hundred two patients (mean age, 61.1 years; 27 women) underwent dual CAC scanning with both EBT and 64-MDCT. The AS and VS were measured with the Aquarius workstation (TeraRecon, Inc, San Mateo, Calif). The correlation coefficient, Bland-Altman analysis, interscanner variation, and agreement in AS and VS scores between EBT and 64-MDCT were computed. RESULTS: Interscan agreement for presence of CAC was 99%. Median values were 286 and 268 mm for AS and 243 and 213 mm for VS with EBT and 64-MDCT, respectively (P > 0.05). There was significant linear relationship between scores from the 2 scanners (R = 0.98 in AS and R = 0.99 in VS; P < 0.001). The interscanner variability between EBT and 64-MDCT was 20.9% and 17.6% in AS and VS, respectively (P = NS). Bland-Altman analysis demonstrated a mean difference in scores of 8.3% for AS and 7.8% by VS. When compared with EBT, there were larger and more prevalent motion artifacts (P < 0.001) and larger mean Hounsfield units using 64-MDCT (P < 0.001). CONCLUSIONS: At CAC scanning, 64-MDCT and EBT were comparable in AS and VS. The interscan variability between scanners is similar to interscan variability of 2 calcium scores done on the same equipment. However, heart rate control was achieved for this study for calcium scores. Whether these results are repeatable without heart rate control needs to be further assessed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/rct.0b013e31817579ee

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Quantification of coronary artery calcium using ultrafast computed tomography

    Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786 · cited 2×

    “The lesion score was calculated by multiplying the lesion area by a density factor derived from the maximal HU within this area as described by Agatston et al.(12) Calcium by volumetric score was determined by isotropic interpolation software as described by Callister et al.”
    Method

Show all 1 references

Cited by

Metadata

Authors
Mao, S. S., Pal, R. S., McKay, C. R., Gao, Y. G., Gopal, A., Ahmadi, N., Child, J., Carson, S., Takasu, J., Sarlak, B., Bechmann, D., & Budoff, M. J.
Venue
Journal of Computer Assisted Tomography
Published
2009-03
Volume
33
Issue
2
Pages
175-178
ISSN
0363-8715 (ISSN-L)
OpenAlex
W1978635777
Cited by
110
References
1
FWCI
4.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.