Radiation Dose Reduction With Chest Computed Tomography Using Adaptive Statistical Iterative Reconstruction Technique: Initial Experience
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
PURPOSE: To assess radiation dose reduction and image quality for weight-based chest computed tomographic (CT) examination results reconstructed using adaptive statistical iterative reconstruction (ASIR) technique. MATERIALS AND METHODS: With local ethical committee approval, weight-adjusted chest CT examinations were performed using ASIR in 98 patients and filtered backprojection (FBP) in 54 weight-matched patients on a 64-slice multidetector CT. Patients were categorized into 3 groups: 60 kg or less (n = 32), 61 to 90 kg (n = 77), and 91 kg or more (n = 43) for weight-based adjustment of noise indices for automatic exposure control (Auto mA; GE Healthcare, Waukesha, Wis). Remaining scan parameters were held constant at 0.984:1 pitch, 120 kilovolts (peak), 40-mm table feed per rotation, and 2.5-mm section thickness. Patients' weight, scanning parameters, and CT dose index volume were recorded. Effective doses (EDs) were estimated. Image noise was measured in the descending thoracic aorta at the level of the carina. Data were analyzed using analysis of variance. RESULTS: Compared with FBP, ASIR was associated with an overall mean (SD) decrease of 27.6% in ED (ASIR, 8.8 [2.3] mSv; FBP, 12.2 [2.1] mSv; P < 0.0001). With the use of ASIR, the ED values were 6.5 (1.8) mSv (28.8% decrease), 7.3 (1.6) mSv (27.3% decrease), and 12.8 (2.3) mSv (26.8% decrease) for the weight groups of 60 kg or less, 61 to 90 kg, and 91 kg or more, respectively, compared with 9.2 (2.3) mSv, 10.0 (2.0) mSv, and 17.4 (2.1) mSv with FBP (P < 0.0001). Despite dose reduction, there was less noise with ASIR (12.6 [2.9] mSv) than with FBP (16.6 [6.2] mSv; P < 0.0001). CONCLUSIONS: Adaptive statistical iterative reconstruction helps reduce chest CT radiation dose and improve image quality compared with the conventionally used FBP image reconstruction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Strategies for CT Radiation Dose Optimization
Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J.-A., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2303021726 · Cited by 1,080
Self-citationA three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937 · cited 1×
“Iterative reconstruction techniques have been proposed as one approach to improving CT image quality.(1,2) Unlike FBP, iterative reconstruction consists of 2 steps.”
MethodSelf-citationCT Dose Reduction and Dose Management Tools: Overview of Available Options
McCollough, C. H., Bruesewitz, M. R., & Kofler, J. M. (2006) · RadioGraphics · doi:10.1148/rg.262055138 · Cited by 768 · cited 1×
“6Y9 In addition, several studies have shown that it is possible to obtain diagnostic information at lower radiation dose despite increase in image noise.(8,9) We found that the ASIR technique allows reduction in radiation dose associated with chest CT while reducing image noise and maintaining structural integrity and…”
MethodTechniques and Applications of Automatic Tube Current Modulation for CT
Kalra, M. K., Maher, M. M., Toth, T. L., Schmidt, B., Westerman, B. L., Morgan, H. T., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2333031150 · Cited by 725 · cited 1×
“The latter technique automatically adjusts tube current within a specified milliampere range in different projection angles around patient’s cross section and along patient’s length in the z-axis based on specified noise index (NI).(3) The NI is a descriptor for userdesired image noise level for particular CT examinat…”
MethodSelf-citationKachelrieß, M., Watzke, O., & Kalender, W. A. (2001) · Medical Physics · doi:10.1118/1.1358303 · Cited by 311
Radiation Dose Reduction in Chest CT: A Review
Kubo, T., Lin, P.-J. P., Stiller, W., Takahashi, M., Kauczor, H.-U., Ohno, Y., & Hatabu, H. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2556 · Cited by 256
Iterative reconstruction algorithms in nuclear medicine
Vandenberghe, S., D’Asseler, Y., Rik Van De Walle, B., Kauppinen, T., Koole, M. J. B., Bouwens, L., Laere, K. V., Lemahieu, I. A., & Dierckx, R. A. (2001) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(00)00060-4 · Cited by 129 · cited 1×
“Use of the iterative reconstruction technique has also been described for nuclear medicine imaging modalitiesVsingle photon emission CT and positron emission tomography.(15) There are some considerations with the ASIR technique used in our study.”
MethodTotal Hip Prosthesis Metal-Artifact Suppression Using Iterative Deblurring Reconstruction
Robertson, D. D., Yuan, J., Wang, G., & Vannier, M. W. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199703000-00024 · Cited by 115 · cited 1×
“Other studies have used the iterative reconstruction techniques to reduce metallic, beam-hardening, cone-beam, and motion artifacts in CT scanning.(10,14) Use of the iterative reconstruction technique has also been described for nuclear medicine imaging modalitiesVsingle photon emission CT and positron emission tomogr…”
MethodNoise and resolution in images reconstructed with FBP and OSC algorithms for CT
Ziegler, A., Köhler, T., & Proksa, R. (2007) · Medical Physics · doi:10.1118/1.2409481 · Cited by 110
Cited by
Iterative reconstruction techniques for computed tomography Part 1: Technical principles
Willemink, M. J., de Jong, P. A., Leiner, T., de Heer, L. M., Nievelstein, R. A. J., Budde, R. P. J., & Schilham, A. M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2765-y · Cited by 443
Singh, S., Kalra, M. K., Gilman, M. D., Hsieh, J., Pien, H. H., Digumarthy, S. R., & Shepard, J.-A. O. (2011) · Radiology · doi:10.1148/radiol.11101450 · Cited by 344
Self-citationKatsura, M., Matsuda, I., Akahane, M., Sato, J., Akai, H., Yasaka, K., Kunimatsu, A., & Ohtomo, K. (2012) · European Radiology · doi:10.1007/s00330-012-2452-z · Cited by 278
Willemink, M. J., Leiner, T., de Jong, P. A., de Heer, L. M., Nievelstein, R. A. J., Schilham, A. M. R., & Budde, R. P. J. (2013) · European Radiology · doi:10.1007/s00330-012-2764-z · Cited by 268
Pontana, F., Duhamel, A., Pagniez, J., Flohr, T., Faivre, J.-B., Hachulla, A.-L., Remy, J., & Remy-Jardin, M. (2011) · European Radiology · doi:10.1007/s00330-010-1991-4 · Cited by 230
“Despite methodological differences, our results can only be compared to those of Prakash et al. [ 16 ], the only group having already reported an experience with iterative reconstructions applied to chest CT. Investigating a different iterative”
ResultA review of patient dose and optimisation methods in adult and paediatric CT scanning
Dougeni, E., Faulkner, K., & Panayiotakis, G. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.05.025 · Cited by 185
Ohno, Y., Takenaka, D., Kanda, T., Yoshikawa, T., Matsumoto, S., Sugihara, N., & Sugimura, K. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.8275 · Cited by 79
“by using other techniques, such as 3D adaptive raw data filter [11], adaptive statistical iterative reconstruction [2–5], and iterative reconstruction in image space [6, 7].”
Method
Metadata
- Authors
- Prakash, P., Kalra, M. K., Digumarthy, S. R., Hsieh, J., Pien, H., Singh, S., Gilman, M. D., & Shepard, J.-A. O.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 2010-01
- Volume
- 34
- Issue
- 1
- Pages
- 40-45
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2017827138
- Cited by
- 188
- References
- 9
- FWCI
- 21.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.