Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 79Radiation Dose and ImagingMedical Imaging Techniques and ApplicationsLung Cancer Diagnosis and Treatment

The DOI matches its Crossref record; 38 of the 39 references it cites were found in a registry or an index.

Adaptive iterative dose reduction using 3D processing for reduced-and low-dose pulmonary CT: comparison with standard-dose CT for image noise reduction and radiological findings

Ohno, Yoshiharu, Takenaka, Daisuke, Kanda, Tomonori, Yoshikawa, Takeshi, Matsumoto, Sumiaki, Sugihara, Naoki, Sugimura, Kazuro·2012·American Journal of Roentgenology

Abstract

Objective The purpose of this study was to determine the utility of adaptive iterative dose reduction using 3D processing (AIDR 3D) for image noise reduction and assessment of radiologic findings obtained with reduced- and low-dose chest CT in patients with various pulmonary diseases. Subjects and methods Chest CT examinations at three different tube current settings and using 16- and 64-MDCT scanners were performed for 37 patients. Standard-dose (150 mAs) data were reconstructed as thin-section CT without AIDR 3D, and low-dose (25 mAs) and reduced-dose (50 mAs) data were reconstructed as thin-section CT without and with AIDR 3D. To compare image quality, image noises at all CT doses were quantitatively assessed by region of interest measurements. For comparison of radiologic finding assessments, likelihoods of occurrence of emphysema, ground-glass opacity, reticular opacity, bronchiectasis, honeycomb pattern, and nodules were evaluated on a 5-point scale. Then, image noise and agreements of radiologic findings between standard-dose CT and others were statistically evaluated. Results The image quality scores of reduced- and low-dose CT without AIDR 3D were significantly lower than those of both protocols with AIDR 3D and standard-dose CT (p 0.81). Conclusion AIDR 3D is useful for image noise reduction and assessment of radiologic findings obtained with reduced- and low-dose CT for patients with various pulmonary diseases.

Overview

Integrity signals

Registry

Crossref · 10.2214/ajr.11.8275

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 39 references

Research works printed but not linked: 2

  1. 10.2214/ajr.07.2630 · doi:10.2214/ajr.07.2630
  2. Markarian B, 1993, Heitzman’s the lung: radiologic-pathologic correlation, 4

Cited by

See all 79

Metadata

Authors
Ohno, Y., Takenaka, D., Kanda, T., Yoshikawa, T., Matsumoto, S., Sugihara, N., & Sugimura, K.
Affiliations
  • Kobe University (JP)
  • Hyogo Prefectural Cancer Center (JP)
  • Toshiba (Japan) (JP)
Venue
American Journal of Roentgenology
Published
2012-10
Volume
199
Issue
4
Pages
W477-W485
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W1964060591
Cited by
79
References
39
Citations by year
2026: 3 · 2025: 2 · 2024: 3 · 2023: 4 · 2022: 4 · 2021: 3 · 2020: 4 · 2019: 5 · 2018: 8 · 2017: 3 · 2016: 8 · 2015: 13 · 2014: 11 · 2013: 7 · 2012: 1
FWCI
7.73
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Roentgenology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
Keywords
adaptive iterative dose reduction, low-dose CT, chest CT, image denoising, image quality, lung disease, emphysema, ground-glass opacities, bronchiectasis, honeycomb pattern, pulmonary nodules, interobserver agreement, tube current reduction
MeSH terms
Adult, Aged, Aged, 80 and over, Female, Humans, Image Processing, Computer-Assisted, Lung, Lung Diseases, Male, Middle Aged, Radiation Dosage, Radiographic Image Enhancement, Tomography, X-Ray Computed, Phantoms, Imaging, Imaging, Three-Dimensional, Signal-To-Noise Ratio, Multidetector Computed Tomography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adaptive iterative dose reduction using 3D processing for reduced-and low-dose pulmonary CT: comparison with standard-dose CT for image noise reduction and radiological findings. https://app.cochat.ai/papers/10.2214/ajr.11.8275
The paper
Ohno, Y., Takenaka, D., Kanda, T., Yoshikawa, T., Matsumoto, S., Sugihara, N., & Sugimura, K. (2012). Adaptive iterative dose reduction using 3D processing for reduced-and low-dose pulmonary CT: comparison with standard-dose CT for image noise reduction and radiological findings. American Journal of Roentgenology. https://doi.org/10.2214/ajr.11.8275

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.