Differentiation of Pancreas Carcinoma From Healthy Pancreatic Tissue Using Multiple b-Values: Comparison of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion Derived Parameters
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To evaluate in detail the diagnostic performance of diffusion-weighted imaging (DWI) to differentiate pancreas carcinoma from healthy pancreas using the apparent diffusion coefficient (ADC) and parameters derived from the intravoxel incoherent motion (IVIM) theory. MATERIALS AND METHODS: Twenty-three patients with pancreas carcinoma and 14 volunteers with healthy pancreas were examined at 1.5 Tesla using a single-shot echo-planar imaging DWI pulse sequence. Eleven b-values ranging from 0 to 800 s/mm2 were used. The acquisition was separated into blocks (b0, b25), (b0, b50),...(b0, b800) and each block was acquired in a single expirational breath-hold (TA = 26 seconds) to avoid motion artifacts. The ADC was calculated for all b-values using linear regression yielding ADC(tot). By applying the IVIM model, which allows for the estimation of perfusion effects in DWI, the perfusion fraction f and the perfusion free diffusion parameter D were calculated. The diagnostic performance of ADC, f and D as a measure for the differentiation between healthy pancreas and pancreatic carcinoma was evaluated with receiver operating characteristics analysis. RESULTS: In the healthy control group, the ADC(tot) ranged from 1.53 to 2.01 microm2/ms with a mean value of 1.71 +/- 0.19 microm2/ms, the perfusion fraction f ranged from 18.5% to 40.4% with a mean value of 25.0 +/- 6.2%, and the diffusion coefficient D from 0.94 to 1.28 microm2/ms with a mean value of 1.13 +/- 0.15 microm2/ms. In patients with pancreas carcinoma, the ADC(tot) ranged from 0.98 to 1.81 microm2/ms with a mean value of 1.31 +/- 0.24 microm2/ms, the perfusion fraction f ranged from 0% to 20.4% with a mean value of 8.59 +/- 4.6% and the diffusion coefficient D from 0.74 to 1.60 microm2/ms with a mean value of 1.15 +/- 0.22 microm2/ms. In comparison to healthy pancreatic tissue, a significant reduction of the perfusion fraction f and of ADC(tot) was found in pancreatic carcinoma (P < 0.00001, 0.0002, respectively). The f value showed more than a 10-fold higher significance level in distinguishing cancerous from normal tissue when compared with the ADC(tot) value. No significant difference in the diffusion coefficient D was observed between the 2 groups (P > 0.5). In the receiver operating characteristic-analyses, the area under curve for f was 0.991 and significantly larger than ADC(tot) (P < 0.05). f had the highest sensitivity, specificity, negative predictive value, and positive predictive value with 95.7%, 100%, 93.3%, and 100%, respectively. CONCLUSIONS: Using the IVIM-approach, the f value proved to be the best parameter for the differentiation between healthy pancreas and pancreatic cancer. The acquisition of several b-values strongly improved the stability of the parameter estimation thus increasing the sensitivity and specificity to 95.7% and 100% respectively. The proposed method may hold great promise for the non invasive, noncontrast-enhanced imaging of pancreas lesions and may eventually become a screening tool for pancreatic cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912 · cited 1×
“The ADC is a combined measure of the molecular movement of water (diffusion) and microcirculation of blood in the capillaries (perfusion).(12) The intravoxel incoherent motion (IVIM) model takes these 2 sources of signal decay into account, thus providing a theoretical framework to derive diffusion and perfusion param…”
BackgroundSeparation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169 · cited 4×
“However, in this work, only 3 b-values were used to calculate the parameters as proposed in.(13) The accuracy of the IVIM derived parameters could greatly profit from the acquisition of more than 3 b-values that would permit more accurate data fitting by reducing the effect of statistical uncertainty of the measured s…”
MethodInfluentialDiffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993 · cited 1×
“First, to minimize motion artifacts, all images were acquired in breath hold expiration.(21,22) Because each expiration cycle may vary slightly considering the position of the pancreas, we acquired a b0 and a corresponding diffusion weighted image in 1 cycle, thus improving the estimation of the signal decay.”
MethodMoseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Sugahara, T., Korogi, Y., Kochi, M., Ikushima, I., Shigematu, Y., Hirai, T., Okuda, T., Liang, L., Ge, Y., Komohara, Y., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199901)9:1<53::aid-jmri7>3.0.co;2-2 · Cited by 1,163
Statistics review 13: receiver operating characteristic curves.
Bewick, V., Cheek, L., & Ball, J. (2004) · Critical Care · doi:10.1186/cc3000 · Cited by 818 · cited 2×
“The area under the ROC-curve (AUC) was compared for significant differences between the parameters and the cutoff values with the largest Yoden index (the sum of sensitivity and specificity) were calculated from the ROC-curve.18 A significance value P less than 0.05 was considered statistically significant.”
MethodInfluentialChenevert, T. L. (2000) · Journal of the National Cancer Institute · doi:10.1093/jnci/92.24.2029 · Cited by 673 · cited 1×
“In brain tumors, DWI-derived apparent diffusion coefficient (ADC) measurement proved to provide information on tumor cellularity that could be used to monitor treatment response.(6,7) Various recent technical advances enabled DWI and measurement of the ADC in the abdomen where organ motion and tissue inhomogeneity hav…”
BackgroundLiver Cirrhosis: Intravoxel Incoherent Motion MR Imaging—Pilot Study
Luciani, A., Vignaud, A., Cavet, M., Tran Van Nhieu, J., Mallat, A., Ruel, L., Laurent, A., Deux, J.-F., Brugieres, P., & Rahmouni, A. (2008) · Radiology · doi:10.1148/radiol.2493080080 · Cited by 612
Yamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519
Evaluation of cancer therapy using diffusion magnetic resonance imaging.
Ross, B. D., Moffat, B. A., Lawrence, T. S., Mukherji, S. K., Gebarski, S. S., Quint, D. J., Johnson, T. D., Junck, L., Robertson, P. L., Muraszko, K. M., et al. (2003) · PubMed · Cited by 257
Cited by
Intravoxel Incoherent Motion in Body Diffusion-Weighted MRI: Reality and Challenges
Koh, D.-M., Collins, D. J., & Orton, M. R. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5515 · Cited by 527
Imaging diagnosis of pancreatic cancer: A state-of-the-art review
Lee, E. S. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i24.7864 · Cited by 401
Andreou, A., Koh, D. M., Collins, D. J., Blackledge, M., Wallace, T., Leach, M. O., & Orton, M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2604-1 · Cited by 287
Toward an optimal distribution of b values for intravoxel incoherent motion imaging
Lemke, A., Stieltjes, B., Schad, L. R., & Laun, F. B. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.03.004 · Cited by 286
Self-citationLemke, A., Laun, F. B., Simon, D., Stieltjes, B., & Schad, L. R. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22565 · Cited by 266
Self-citationMeasuring brain perfusion with intravoxel incoherent motion (IVIM): Initial clinical experience
Federau, C., O'Brien, K., Meuli, R., Hagmann, P., & Maeder, P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24195 · Cited by 204
“Recently, promising results to measure perfusion with the IVIM technique have been achieved in various diseases of different body organs, for example in cirrhotic liver (16), in nonalcoholic fatty liver disease (17), and in the kidney during ureteral obstruction (18), as well as in focal cancer lesions observed in pan…”
BackgroundDiffusion‐weighted imaging outside the brain: Consensus statement from an ISMRM‐sponsored workshop
Taouli, B., Beer, A. J., Chenevert, T., Collins, D., Lehman, C., Matos, C., Padhani, A. R., Rosenkrantz, A. B., Shukla‐Dave, A., Sigmund, E., et al. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25196 · Cited by 175
“IVIM is increasingly applied in a wide variety of cancer types, due to their typically hypervascular and hypercellular features.(32,110,113) Data showing superiority of IVIM parameters over ADC for tissue characterization is limited, and more evidence is needed.”
Kang, K. M., Lee, J. M., Yoon, J. H., Kiefer, B., Han, J. K., & Choi, B. I. (2014) · Radiology · doi:10.1148/radiol.13122712 · Cited by 162
“Yet, atypical enhancement patterns of PACs or NETs are not rare at dynamic MR imaging or CT (28,29) because of tumor size, degree of differentiation, and PAC from NP, CP, and NETs.”
BackgroundResultInfluentialCohen, A. D., Schieke, M. C., Hohenwalter, M. D., & Schmainda, K. M. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25109 · Cited by 105
Metadata
- Authors
- Lemke, A., Laun, F. B., Klau, M., Re, T. J., Simon, D., Delorme, S., Schad, L. R., & Stieltjes, B.
- Venue
- Investigative Radiology
- Published
- 2009-12
- Volume
- 44
- Issue
- 12
- Pages
- 769-775
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2093088130
- Cited by
- 231
- References
- 21
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.