Cardiothoracic Applications of 3-dimensional Printing
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Medical 3-dimensional (3D) printing is emerging as a clinically relevant imaging tool in directing preoperative and intraoperative planning in many surgical specialties and will therefore likely lead to interdisciplinary collaboration between engineers, radiologists, and surgeons. Data from standard imaging modalities such as computed tomography, magnetic resonance imaging, echocardiography, and rotational angiography can be used to fabricate life-sized models of human anatomy and pathology, as well as patient-specific implants and surgical guides. Cardiovascular 3D-printed models can improve diagnosis and allow for advanced preoperative planning. The majority of applications reported involve congenital heart diseases and valvular and great vessels pathologies. Printed models are suitable for planning both surgical and minimally invasive procedures. Added value has been reported toward improving outcomes, minimizing perioperative risk, and developing new procedures such as transcatheter mitral valve replacements. Similarly, thoracic surgeons are using 3D printing to assess invasion of vital structures by tumors and to assist in diagnosis and treatment of upper and lower airway diseases. Anatomic models enable surgeons to assimilate information more quickly than image review, choose the optimal surgical approach, and achieve surgery in a shorter time. Patient-specific 3D-printed implants are beginning to appear and may have significant impact on cosmetic and life-saving procedures in the future. In summary, cardiothoracic 3D printing is rapidly evolving and may be a potential game-changer for surgeons. The imager who is equipped with the tools to apply this new imaging science to cardiothoracic care is thus ideally positioned to innovate in this new emerging imaging modality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
Holmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.001 · Cited by 749
Achenbach, S., Delgado, V., Hausleiter, J., Schoenhagen, P., Min, J. K., & Leipsic, J. A. (2012) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2012.11.002 · Cited by 634
Medical 3D Printing for the Radiologist
Mitsouras, D., Liacouras, P., Imanzadeh, A., Giannopoulos, A. A., Cai, T., Kumamaru, K. K., George, E., Wake, N., Caterson, E. J., Pomahac, B., et al. (2015) · RadioGraphics · doi:10.1148/rg.2015140320 · Cited by 619
Self-citationMorrison, R. J., Hollister, S. J., Niedner, M. F., Mahani, M. G., Park, A. H., Mehta, D. K., Ohye, R. G., & Green, G. E. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.3010825 · Cited by 498
Lim, K. H. A., Loo, Z. Y., Goldie, S. J., Adams, J. W., & McMenamin, P. G. (2016) · Anatomical Sciences Education · doi:10.1002/ase.1573 · Cited by 494
Accuracy of medical models made by additive manufacturing (rapid manufacturing)
Salmi, M., Paloheimo, K.-S., Tuomi, J., Wolff, J., & Mäkitie, A. (2013) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2012.11.041 · Cited by 330
Schievano, S., Migliavacca, F., Coats, L., Khambadkone, S., Carminati, M., Wilson, N., Deanfield, J. E., Bonhoeffer, P., & Taylor, A. M. (2007) · Radiology · doi:10.1148/radiol.2422051994 · Cited by 232
Schmauss, D., Haeberle, S., Hagl, C., & Sodian, R. (2015) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu310 · Cited by 212
Jacobs, S., Grunert, R., Mohr, F. W., & Falk, V. (2008) · Interactive CardioVascular and Thoracic Surgery · doi:10.1510/icvts.2007.156588 · Cited by 206
Ripley, B., Kelil, T., Cheezum, M. K., Goncalves, A., Di Carli, M. F., Rybicki, F. J., Steigner, M., Mitsouras, D., & Blankstein, R. (2016) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.12.004 · Cited by 205
Self-citationHolmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.24351 · Cited by 200
Rapid Prototyping: A New Tool in Understanding and Treating Structural Heart Disease
Kim, M. S., Hansgen, A. R., Wink, O., Quaife, R. A., & Carroll, J. D. (2008) · Circulation · doi:10.1161/circulationaha.107.740977 · Cited by 188
Olivieri, L. J., Krieger, A., Loke, Y.-H., Nath, D. S., Kim, P. C. W., & Sable, C. A. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.12.016 · Cited by 182
Costello, J. P., Olivieri, L. J., Krieger, A., Thabit, O., Marshall, M. B., Yoo, S.-J., Kim, P. C., Jonas, R. A., & Nath, D. S. (2014) · World Journal for Pediatric and Congenital Heart Surgery · doi:10.1177/2150135114528721 · Cited by 170
Three-dimensional Physical Modeling: Applications and Experience at Mayo Clinic
Matsumoto, J. S., Morris, J. M., Foley, T. A., Williamson, E. E., Leng, S., McGee, K. P., Kuhlmann, J. L., Nesberg, L. E., & Vrtiska, T. J. (2015) · RadioGraphics · doi:10.1148/rg.2015140260 · Cited by 166
Replicating Patient-Specific Severe Aortic Valve Stenosis With Functional 3D Modeling
Maragiannis, D., Jackson, M. S., Igo, S. R., Schutt, R. C., Connell, P., Grande-Allen, J., Barker, C. M., Chang, S. M., Reardon, M. J., Zoghbi, W. A., et al. (2015) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.115.003626 · Cited by 163
Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing
Biglino, G., Verschueren, P., Zegels, R., Taylor, A. M., & Schievano, S. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-2 · Cited by 162
Current progress in tissue engineering of heart valves: multiscale problems, multiscale solutions
Cheung, D. Y., Duan, B., & Butcher, J. T. (2015) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.2015.1051527 · Cited by 160
3 D printed models for planning endovascular stenting in transverse aortic arch hypoplasia
Valverde, I., Gomez, G., Coserria, J. F., Suarez‐Mejias, C., Uribe, S., Sotelo, J., Velasco, M. N., Santos De Soto, J., Hosseinpour, A., & Gomez‐Cia, T. (2015) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25810 · Cited by 146
Schmauß, D., Schmitz, C., Bigdeli, A. K., Weber, S., Gerber, N., Beiras-Fernández, A., Schwarz, F., Becker, C. R., Kupatt, C., & Sodian, R. (2012) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2011.09.031 · Cited by 143
Shiraishi, I., Yamagishi, M., Hamaoka, K., Fukuzawa, M., & Yagihara, T. (2009) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2009.07.046 · Cited by 142
Tam, M. D. B. S., Laycock, S. D., Brown, J. R., & Jakeways, M. (2013) · Journal of Endovascular Therapy · doi:10.1583/13-4450mr.1 · Cited by 130
Tridimensional titanium-printed custom-made prosthesis for sternocostal reconstruction
Aranda, J. L., Jiménez, M. F., Rodríguez, M., & Varela, G. (2015) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezv265 · Cited by 124
Getting in touch—3D printing in Forensic Imaging
Ebert, L. C., Thali, M. J., & Ross, S. G. (2011) · Forensic Science International · doi:10.1016/j.forsciint.2011.04.022 · Cited by 117
Physical Models Aiding in Complex Congenital Heart Surgery
Mottl-Link, S., Hübler, M., Kühne, T., Rietdorf, U., Krueger, J. J., Schnackenburg, B., Simone, R. D., Berger, F. F., Juraszek, A. L., Meinzer, H.-P., et al. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2007.06.001 · Cited by 115
Zopf, D., Flanagan, C. L., Wheeler, M. B., Hollister, S. J., & Green, G. E. (2014) · JAMA Otolaryngology–Head & Neck Surgery · doi:10.1001/jamaoto.2013.5644 · Cited by 114
Use of rapid prototyping models in the planning of percutaneous pulmonary valved stent implantation
Armillotta, A., Bonhoeffer, P., Dubini, G., Ferragina, S., Migliavacca, F., Sala, G., & Schievano, S. (2007) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim83 · Cited by 102
Development of Patient-Specific Three-Dimensional Pediatric Cardiac Models
Noecker, A. M., Chen, J.-F., Zhou, Q., White, R. D., Kopcak, M. W., Arruda, M. J., & Duncan, B. W. (2006) · ASAIO Journal · doi:10.1097/01.mat.0000217962.98619.ab · Cited by 95
The practical clinical value of three-dimensional models of complex congenitally malformed hearts
Riesenkampff, E., Rietdorf, U., Ivo Wolf, A., Schnackenburg, B., Ewert, P., Huebler, M., Alexi-Meskishvili, V. V., Anderson, R. H., Engel, N., Meinzer, H.-P., et al. (2009) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2009.03.011 · Cited by 93
Olivieri, L., Krieger, A., Chen, M. Y., Kim, P. S.-H., & Kanter, J. P. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.12.192 · Cited by 88
Three-Dimensional Printing of Mitral Valve Using Echocardiographic Data
Mahmood, F. U., Owais, K., Taylor, C., Montealegre-Gallegos, M., Manning, W. J., Matyal, R., & Khabbaz, K. R. (2014) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2014.06.020 · Cited by 87
Wang, K., Zhao, Y., Chang, Y.-H., Qian, Z. Y., Zhang, C., Wang, B., Vannan, M. A., & Wang, M. J. (2015) · Materials & Design · doi:10.1016/j.matdes.2015.11.022 · Cited by 87
Yang, D. H., Kang, J., Kim, N., Song, J., Lee, J., & Lim, T. (2015) · Circulation · doi:10.1161/circulationaha.115.015842 · Cited by 85
Factors Affecting Dimensional Accuracy of 3-D Printed Anatomical Structures Derived from CT Data
Ogden, K. M., Aslan, C., Ordway, N. R., Diallo, D., Tillapaugh-Fay, G. M., & Soman, P. (2015) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-015-9803-7 · Cited by 82
Sodian, R., Schmauß, D., Schmitz, C., Bigdeli, A. K., Haeberle, S., Schmoeckel, M., Markert, M., Lueth, T. C., Freudenthal, F. P., Reichart, B., et al. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2009.03.014 · Cited by 79
Three‐dimensional printing of MRI‐visible phantoms and MR image‐guided therapy simulation
Mitsouras, D., Lee, T. C., Liacouras, P. C., Ionita, C. N., Pietila, T., Maier, S. E., & Mulkern, R. V. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26136 · Cited by 79
Self-citationThree-Dimensional Ultrasound-Derived Physical Mitral Valve Modeling
Witschey, W. R. T., Pouch, A. M., McGarvey, J. R., Ikeuchi, K., Contijoch, F. J., Levack, M. M., Yushkevick, P. A., Sehgal, C. M., Jackson, B. M., Gorman, R. C., et al. (2014) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2014.04.094 · Cited by 71
Ryan, J. R., Moe, T. G., Richardson, R. R., Frakes, D. H., Nigro, J. J., & Pophal, S. G. (2014) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2014.04.030 · Cited by 67
Hybrid 3D printing: a game-changer in personalized cardiac medicine?
Kurup, H. K. N., Samuel, B. P., & Vettukattil, J. J. (2015) · Expert Review of Cardiovascular Therapy · doi:10.1586/14779072.2015.1100076 · Cited by 66
Functional 3D Printed Patient-Specific Modeling of Severe Aortic Stenosis
Maragiannis, D., Jackson, M., Igo, S. R., Chang, S. M., Zoghbi, W. A., & Little, S. H. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.05.058 · Cited by 63
Giannopoulos, A. A., Chepelev, L. L., Sheikh, A. M., Wang, A., Dang, W., Akyuz, E., Hong, C. J. H., Wake, N., Pietila, T., Dydynski, P. B., et al. (2015) · 3D Printing in Medicine · doi:10.1186/s41205-015-0002-4 · Cited by 63
Self-citationRuss, M. K., O'Hara, R., Nagesh, S. V. S., Mokin, M. V., Jiménez, C., Siddiqui, A. H., Bednarek, D. R., Rudin, S., & Ionita, C. N. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2081997 · Cited by 59
Echocardiography derived three-dimensional printing of normal and abnormal mitral annuli
Mahmood, F. U., Owais, K., Montealegre-Gallegos, M., Matyal, R., Panzica, P., Maslow, A. D., & Khabbaz, K. R. (2014) · Annals of Cardiac Anaesthesia · doi:10.4103/0971-9784.142062 · Cited by 51
Airway Stent Insertion Simulated With a Three-Dimensional Printed Airway Model
Miyazaki, T., Yamasaki, N., Tsuchiya, T., Matsumoto, K., Takagi, K., & Nagayasu, T. (2014) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2014.10.021 · Cited by 51
Markl, M., Schumacher, R., Küffer, J., Bley, T. A., & Hennig, J. (2005) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-005-0019-6 · Cited by 50
Percutaneous Pulmonary Valve Implantation in a Native Outflow Tract
Poterucha, J. T., Foley, T. A., & Taggart, N. W. (2014) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2014.03.015 · Cited by 49
Individualizing Management of Complex Esophageal Pathology Using Three-Dimensional Printed Models
Dickinson, K. J., Matsumoto, J. M. S., Cassivi, S. D., Reinersman, J. M., Fletcher, J. G., Morris, J., Song, L. M. W. K., & Blackmon, S. H. (2015) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2015.03.115 · Cited by 38
İzgi, C., Nyktari, E. G., Alpendurada, F., Bruengger, A. A. S., Pepper, J., Treasure, T., & Mohiaddin, R. H. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.06.015 · Cited by 22
The effect of heart rhythm on patient radiation dose with dual-source cardiac computed tomography
Techasith, T., Ghoshhajra, B. B., Truong, Q. A., Pale, R., Nasir, K., Bolen, M. A., Hoffmann, U., Cury, R. C., Abbara, S., Brady, T. J., et al. (2011) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2011.05.003 · Cited by 18
Echocardiography derived three- dimensional printing of normal and abnormal mitral annuli
Kapur, K., & Garg, N. (2014) · Annals of Cardiac Anaesthesia · doi:10.4103/0971-9784.142063 · Cited by 16
Three dimensional printing of an atrial septal defect: Is it multimodality imaging?
Faganello, G., Campana, C., Belgrano, M., Russo, G., Pozzi, M., Cioffi, G., & Lenarda, A. D. (2015) · International journal of cardiac imaging · doi:10.1007/s10554-015-0801-0 · Cited by 14
Cited by
Current and emerging applications of 3D printing in medicine
Liaw, C.-Y., & Guvendiren, M. (2017) · Biofabrication · doi:10.1088/1758-5090/aa7279 · Cited by 604
Applications of 3D printing in cardiovascular diseases
Giannopoulos, A. A., Mitsouras, D., Yoo, S.-J., Liu, P. P., Chatzizisis, Y. S., & Rybicki, F. J. (2016) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2016.170 · Cited by 421
Self-citationMeasuring and Establishing the Accuracy and Reproducibility of 3D Printed Medical Models
George, E., Liacouras, P., Rybicki, F. J., & Mitsouras, D. (2017) · RadioGraphics · doi:10.1148/rg.2017160165 · Cited by 283
Self-citation
Metadata
- Authors
- Giannopoulos, A. A., Steigner, M. L., George, E., Barile, M., Hunsaker, A. R., Rybicki, F. J., & Mitsouras, D.
- Venue
- Journal of Thoracic Imaging
- Published
- 2016-09
- Volume
- 31
- Issue
- 5
- Pages
- 253-272
- ISSN
- 0883-5993 (ISSN-L)
- OpenAlex
- W2345872234
- Cited by
- 164
- References
- 51
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.