Robotic-assisted Versus Laparoscopic Cholecystectomy: Outcome and Cost Analyses of a Case-matched Control Study
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To compare safety and costs of robotic-assisted and laparoscopic cholecystectomy in patients with symptomatic cholecystolithiasis. BACKGROUND: Technical benefits of robotic-assisted surgery are well documented. However, pressure is currently applied to decrease costs, leading to restriction of development, and implementation of new technologies. So far, no convincing data are available comparing outcome or costs between computer assisted and conventional laparoscopic cholecystectomy. METHODS: A prospective case-matched study was conducted on 50 consecutive patients, who underwent robotic-assisted cholecystectomy (Da Vinci Robot, Intuitive Surgical) between December 2004 and February 2006. These patients were matched 1:1 to 50 patients with conventional laparoscopic cholecystectomy, according to age, gender, American Society of Anesthesiologists score, histology, and surgical experience. Endpoints were complications after surgery (mean follow-up of 12.3 months [SD 1.2]), conversion rates, operative time, and hospital costs (ClinicalTrial.gov ID: NCT00562900). RESULTS: No minor, but 1 major complication occurred in each group (2%). No conversion to open surgery was needed in either group. Operation time (skin-to-skin, 55 minutes vs. 50 minutes, P < 0.85) and hospital stay (2.6 days vs. 2.8 days) were similar. Overall hospital costs were significantly higher for robotic-assisted cholecystectomy $7985.4 (SD 1760.9) versus $6255.3 (SD 1956.4), P < 0.001, with a raw difference of $1730.1(95% CI 991.4-2468.7) and a difference adjusted for confounders of $1606.4 (95% CI 1076.7-2136.2). This difference was mainly related to the amortization and consumables of the robotic system. CONCLUSIONS: Robotic-assisted cholecystectomy is safe and, therefore, a valuable approach. Costs of robots, however, are high and do not justify the use of this technology considering the lack of benefits for patients. A reduction of acquisition and maintenance costs for the robotic system is a prerequisite for large-scale adoption and implementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dindo, D., Demartines, N., & Clavien, P.-A. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000133083.54934.ae · Cited by 31,378 · cited 1×
“Complications were graded according to a validated therapyorientated complication score on a 5-point scale.(27) Severe complications were defined as an event requiring intervention in local or general anesthesia or treatment in the intensive care unit (complications grades 3 and 4).”
MethodSelf-citationValidation of a combined comorbidity index
Charlson, M., Szatrowski, T. P., Peterson, J., & Gold, J. (1994) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)90129-5 · Cited by 6,587 · cited 1×
“Interestingly, although the surgical experience did not influence the operating time in the robotic group (53 minutes (22) for junior surgeon, 56 minutes (23) for experienced surgeon, there was a difference in the laparoscopic group of 31 minutes (71 minutes ( 28 ) for junior surgeon, 40 minutes (15) for experienced s…”
BackgroundRobotic surgery, telerobotic surgery, telepresence, and telementoring
Ballantyne, G. H. (2002) · Surgical Endoscopy · doi:10.1007/s00464-001-8283-7 · Cited by 644
Hanly, E. J., & Talamini, M. A. (2004) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2004.08.020 · Cited by 332 · cited 2×
“Although this study failed to identify any clinical benefits for the patients after robotic-assisted cholecystectomy, based on the safety and ease of use, it confirms the potential important value of robotic cholecystectomy as an ideal starting procedure for robotic surgeons in abdominal surgery, as also described by…”
BackgroundFirst experiences with the da Vinci™ operating robot in thoracic surgery☆
Bodner, J., Wykypiel, H., Wetscher, G., & Schmid, T. (2004) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2004.02.001 · Cited by 319 · cited 1×
“The setup time for the robotic system before skin incision was 17 minutes (8) and 8 minutes ( 4 ) for the laparoscopic group.”
Hashizume, M., Shimada, M., Tomikawa, M., Ikeda, Y., Takahashi, I., Abe, R., Koga, F., Gotoh, N., Konishi, K., Maehara, S., et al. (2002) · Surgical Endoscopy · doi:10.1007/s004640080154 · Cited by 294 · cited 1×
“Interestingly, although the surgical experience did not influence the operating time in the robotic group (53 minutes (22) for junior surgeon, 56 minutes ( 23 ) for experienced surgeon, there was a difference in the laparoscopic group of 31 minutes (71 minutes (28) for junior surgeon, 40 minutes (15) for experienced s…”
BackgroundLOTAN, Y., CADEDDU, J. A., & GETTMAN, M. T. (2004) · Journal of Urology · doi:10.1097/01.ju.0000139714.09832.47 · Cited by 286
Robotic Surgical Training in an Academic Institution
Chitwood, W. R., Nifong, L. W., Chapman, W. H. H., Felger, J. E., Bailey, B. M., Ballint, T., Mendleson, K. G., Kim, V. B., Young, J. A., & Albrecht, R. A. (2001) · Annals of Surgery · doi:10.1097/00000658-200110000-00007 · Cited by 227
A Prospective Comparison of Robotic and Laparoscopic Pyeloplasty
Link, R. E., Bhayani, S. B., & Kavoussi, L. R. (2006) · Annals of Surgery · doi:10.1097/01.sla.0000205626.71982.32 · Cited by 200
Telerobotic Laparoscopic Cholecystectomy: Initial Clinical Experience With 25 Patients
Marescaux, J., Smith, M. K., Fölscher, D., Jamali, F., Malassagne, B., & Leroy, J. (2001) · Annals of Surgery · doi:10.1097/00000658-200107000-00001 · Cited by 185
Cited by
Adverse Events in Robotic Surgery: A Retrospective Study of 14 Years of FDA Data
Alemzadeh, H., Raman, J., Leveson, N., Kalbarczyk, Z., & Iyer, R. K. (2016) · PLOS ONE · doi:10.1371/journal.pone.0151470 · Cited by 441
Maeso, S., Reza, M., Mayol, J. A., Blasco, J. A., Guerra, M., Andradas, E., & Plana, M. N. (2010) · Annals of Surgery · doi:10.1097/sla.0b013e3181e6239e · Cited by 399
Diana, M., & Marescaux, J. (2015) · British Journal of Surgery · doi:10.1002/bjs.9711 · Cited by 318
Robotic Compared With Laparoscopic Sacrocolpopexy: A Randomized Controlled Trial
Anger, J. T., Mueller, E. R., Tarnay, C., Smith, B., Stroupe, K., Rosenman, A., Brubaker, L., Bresee, C., & Kenton, K. (2014) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000000006 · Cited by 263
Metadata
- Authors
- Breitenstein, S., Nocito, A., Puhan, M., Held, U., Weber, M., & Clavien, P.-A.
- Venue
- Annals of Surgery
- Published
- 2008-06
- Volume
- 247
- Issue
- 6
- Pages
- 987-993
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2056305540
- Cited by
- 195
- References
- 16
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.