Development of Volume Conductor and Source Models to Localize Epileptic Foci
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
SUMMARY: There is increasing interest in mapping and source reconstruction from electrocorticoencephalographic (ECoG) grid data and comparison to surface EEG evaluations of epileptic patients. ECoG mapping onto three-dimensional renderings of the individual cortical anatomy derived from magnetic resonance images and computed tomography (CT) is performed after coregistration of anatomical and functional coordinate systems. Source reconstructions from ECoG and EEG are compared using different source models and realistically shaped volume conductor models. Realistically shaped volume conductor models for EEG source reconstruction are a prerequisite for improved localization accuracy. Individual boundary element method (BEM) models derived from MRI represent the "gold standard" and can approximate isotropic homogeneous head compartments and thus give an improved description of the head shape as compared with classical oversimplifying spherical shell models. Anisotropic volume conduction properties of the bone layer or the white matter fibers can be described by the finite element method (FEM); unfortunately, these models require a huge computational effort and are thus not used in daily applications. To avoid this computational effort, head models derived from an averaged MRI dataset can be used. Highly refined models with a large number of nodes and thus better numerical accuracy can be used by this approach, because the setup is performed only once and the decomposed models or precomputed leadfield matrices are saved for later application. Individual image data are not at all needed, if an overlay of the reconstruction results with the anatomy is not desired. With precomputed leadfield matrices and linear interpolation techniques, at least standardized BEM and FEM volume conductor models derived from averaged MRI datasets can achieve the same computational speed as analytical spherical models. The smoothed cortical envelope is used as a realistically shaped single-shell volume conductor model for ECoG source reconstruction, whereas three-compartment BEM-models are required for EEG. The authors describe how to localize ECoG-grid electrode positions and how to segment the cortical surface from coregistered magnetic resonance and CT images. Landmark-based coregistration is performed using common fiducials in both image modalities. Another more promising automatic approach is based on mutual three-dimensional volume gray-level information. The ECoG electrode positions can be retrieved from three-dimensional CT slices manually using cursors in thresholded images with depth information. Alternatively, the smoothed envelope of the cortical surface segmented from the MRI is used to semiautomatically determine the grid electrode positions by marking the four corners and measuring distances along the smoothed surface. With extended source patches for cortically constrained scans and current density reconstructions, results from ECoG and surface EEG data were compared. Single equivalent dipoles were used to explain the EEG far fields, and results were compared with the original current density distributions explaining the ECoG data. The authors studied the performance of spherical and realistically shaped BEM volume conductor models for EEG and ECoG source reconstruction in spherical and nonspherical parts of the head with simulations and measured epileptic spike data. Only small differences between spherical and realistically shaped models were found in the spherical parts of the head, whereas realistically shaped models are superior to spherical approximations in both single-shell ECoG and three-shell EEG cases in the nonspherical parts, such as the temporal lobe areas. The ECoG near field is more complicated to interpret than the surface EEG far field and cannot be explained in general by simple equivalent dipoles. However, from simulations with realistically shaped volume conductor models and cortically constrained source models, the authors studied how the bone and skin layer act as spatial low pass filters that smooth and simplify the surface EEG maps generated by much more complicated-looking source configurations derived from measured ECoG data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989 · cited 3×
“…already discussed and improved the BEM ( Cuffin, 1990; Ferguson and Stroink, 1997; Frijns et al., 2000; Fletcher et al., 1995; Fuchs et al., 1998, 2001; Geselowitz, 1967; Hämäläinen and Sarvas, 1989; Meijs et al., 1989; Musha and Okamoto, 1999; Oostendorp and Oosterom, 1989; Yvert et al., 1995).”
BackgroundMethod
Cited by
Good practice for conducting and reporting MEG research
Gross, J., Baillet, S., Barnes, G. R., Henson, R. N., Hillebrand, A., Jensen, O., Jerbi, K., Litvak, V., Maess, B., Oostenveld, R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.001 · Cited by 738
EEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 705
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
Signal quality of simultaneously recorded invasive and non-invasive EEG
Ball, T., Kern, M., Mutschler, I., Aertsen, A., & Schulze-Bonhage, A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.028 · Cited by 403
“volume conduction from within the scull to the outside (Ball et al., 1999; Fuchs et al., 2007; Holsheimer and Feenstra, 1977; van den Broek et al., 1998), in particular using”
BackgroundModeling of the human skull in EEG source analysis
Dannhauer, M., Lanfer, B., Wolters, C. H., & Knösche, T. R. (2011) · Human Brain Mapping · doi:10.1002/hbm.21114 · Cited by 268
Metadata
- Authors
- Fuchs, M., Wagner, M., & Kastner, J.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2007-04
- Volume
- 24
- Issue
- 2
- Pages
- 101-119
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2027779628
- Cited by
- 108
- References
- 2
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of Volume Conductor and Source Models to Localize Epileptic Foci. https://app.cochat.ai/papers/10.1097/wnp.0b013e318038fb3e
- The paper
- Fuchs, M., Wagner, M., & Kastner, J. (2007). Development of Volume Conductor and Source Models to Localize Epileptic Foci. Journal of Clinical Neurophysiology. https://doi.org/10.1097/wnp.0b013e318038fb3e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.