Removal of EEG Noise and Artifact Using Blind Source Separation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A study was performed to investigate and compare the relative performance of blind signal separation (BSS) algorithms at separating common types of contamination from EEG. The study develops a novel framework for investigating and comparing the relative performance of BSS algorithms that incorporates a realistic EEG simulation with a known mixture of known signals and an objective performance metric. The key finding is that although BSS is an effective and powerful tool for separating and removing contamination from EEG, the quality of the separation is highly dependant on the type of contamination, the degree of contamination, and the choice of BSS algorithm. BSS appears to be most effective at separating muscle and blink contamination and less effective at saccadic and tracking contamination. For all types of contamination, principal components analysis is a strong performer when the contamination is greater in amplitude than the brain signal whereas other algorithms such as second-order blind inference and Infomax are generally better for specific types of contamination of lower amplitude.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dealing with artifacts: The EOG contamination of the event-related brain potential
Gratton, G. (1998) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03209415 · Cited by 142
Cited by
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Automatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals
Winkler, I., Haufe, S., & Tangermann, M. (2011) · Behavioral and Brain Functions · doi:10.1186/1744-9081-7-30 · Cited by 778
Signal quality of simultaneously recorded invasive and non-invasive EEG
Ball, T., Kern, M., Mutschler, I., Aertsen, A., & Schulze-Bonhage, A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.028 · Cited by 403
Smith, E. E., Reznik, S. J., Stewart, J. L., & Allen, J. J. B. (2017) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2016.11.005 · Cited by 335
Robust artifactual independent component classification for BCI practitioners
Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., & Tangermann, M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035013 · Cited by 327
Metadata
- Authors
- Fitzgibbon, S. P., Powers, D. M. W., Pope, K. J., & Clark, C. R.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2007-06
- Volume
- 24
- Issue
- 3
- Pages
- 232-243
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2034356418
- Cited by
- 106
- References
- 1
- FWCI
- 1.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Removal of EEG Noise and Artifact Using Blind Source Separation. https://app.cochat.ai/papers/10.1097/wnp.0b013e3180556926
- The paper
- Fitzgibbon, S. P., Powers, D. M. W., Pope, K. J., & Clark, C. R. (2007). Removal of EEG Noise and Artifact Using Blind Source Separation. Journal of Clinical Neurophysiology. https://doi.org/10.1097/wnp.0b013e3180556926
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.