Long-Term, Prospective, Multicenter Study of Poly-4-Hydroxybutyrate Mesh (Phasix Mesh) for Hernia Repair in Cohort at Risk for Complication: 60-Month Follow-Up

Roth, John Scott, Anthone, Gary J, Selzer, Don J, Poulose, Benjamin K, Pierce, Richard A, Bittner, James G, Hope, William W, Dunn, Raymond M, Martindale, Robert G, Goldblatt, Matthew I, Earle, David B, Romanelli, John R, Mancini, Gregory J, Greenberg, Jacob A, Linn, John G, Parra-Davila, Eduardo, Sandler, Bryan J, Deeken, Corey R, Badhwar, Amit, Salluzzo, Jennifer L, Voeller, Guy R·2022·Journal of the American College of Surgeons

Abstract

BACKGROUND: Long-term resorbable mesh represents a promising technology for ventral and incisional hernia repair (VIHR). This study evaluates poly-4-hydroxybutyrate mesh (P4HB; Phasix Mesh) among comorbid patients with CDC class I wounds. STUDY DESIGN: This prospective, multi-institutional study evaluated P4HB VIHR in comorbid patients with CDC class I wounds. Primary outcomes included hernia recurrence and surgical site infection. Secondary outcomes included pain, device-related adverse events, quality of life, reoperation, procedure time, and length of stay. Evaluations were scheduled at 1, 3, 6, 12, 18, 24, 30, 36, and 60 months. A time-to-event analysis (Kaplan-Meier) was performed for primary outcomes; secondary outcomes were reported as descriptive statistics. RESULTS: A total of 121 patients (46 male, 75 female) 54.7 ± 12.0 years old with a BMI of 32.2 ± 4.5 kg/m 2 underwent VIHR with P4HB Mesh (mean ± SD). Fifty-four patients (44.6%) completed the 60-month follow-up. Primary outcomes (Kaplan-Meier estimates at 60 months) included recurrence (22.0 ± 4.5%; 95% CI 11.7% to 29.4%) and surgical site infection (10.1 ± 2.8%; 95% CI 3.3 to 14.0). Secondary outcomes included seroma requiring intervention (n = 9), procedure time (167.9 ± 82.5 minutes), length of stay (5.3 ± 5.3 days), reoperation (18 of 121, 14.9%), visual analogue scale–pain (change from baseline –3.16 ± 3.35 cm at 60 months; n = 52), and Carolinas Comfort Total Score (change from baseline –24.3 ± 21.4 at 60 months; n = 52). CONCLUSIONS: Five-year outcomes after VIHR with P4HB mesh were associated with infrequent complications and durable hernia repair outcomes. This study provides a framework for anticipated long-term hernia repair outcomes when using P4HB mesh.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/xcs.0000000000000363

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Figures

Graphical abstract
Graphical abstract CC BY-NC-ND · PubMed Central
Figure 1. Flow of patients throughout the study period. P4HB, poly-4-hydroxybutyrate.
Figure 1. Flow of patients throughout the study period. P4HB, poly-4-hydroxybutyrate.CC BY-NC-ND · PubMed Central
Figure 2. Primary and secondary study endpoints: (A and B) Kaplan-Meier curves for hernia recurrence and surgical site infection (SSI) in all patients treated with poly-4-hydroxybutyrate mesh (dotted lines = 95% CI; there were no additional SSI after 37 days). (C) Visual Analogue Scale for Pain (mean). (D) Carolinas Comfort Scale–Total Score (mean). (E) SF-12 Physical Component Score (mean). (F) SF-12 Mental Component Score (mean). *p < 0.05 (baseline vs 60 months).
Figure 2. Primary and secondary study endpoints: (A and B) Kaplan-Meier curves for hernia recurrence and surgical site infection (SSI) in all patients treated with poly-4-hydroxybutyrate mesh (dotted lines = 95% CI; there were no additional SSI after 37 days). (C) Visual Analogue Scale for Pain (mean). (D) Carolinas Comfort Scale–Total Score (mean). (E) SF-12 Physical Component Score (mean). (F) SF-12 Mental Component Score (mean). *p < 0.05 (baseline vs 60 months).CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 22

  1. Deeken, 2013, Characterization of the mechanical strength, resorption properties, and histologic characteristics of a fully absorbable material (poly-4-hydroxybutyrate-PHASIX Mesh) in a porcine model of hernia repair., ISRN Surg, 2013, 238067, 10.1155/2013/238067 · DOI · Paper page
  2. Dayton, 1986, Use of an absorbable mesh to repair contaminated abdominal-wall defects., Arch Surg, 121, 954, 10.1001/archsurg.1986.01400080100019 · doi:10.1001/archsurg.1986.01400080100019
  3. Martin, 2013, Characterization of poly-4-hydroxybutyrate mesh for hernia repair applications., J Surg Res, 184, 766, 10.1016/j.jss.2013.03.044 · DOI · Paper page
  4. Roth, 2018, Prospective evaluation of poly-4-hydroxybutyrate mesh in CDC class I/high-risk ventral and incisional hernia repair: 18-month follow-up., Surg Endosc, 32, 1929, 10.1007/s00464-017-5886-1 · DOI · Paper page
  5. Plymale, 2018, Ventral hernia repair with poly-4-hydroxybutyrate mesh., Surg Endosc, 32, 1689, 10.1007/s00464-017-5848-7 · DOI · Paper page
  6. Messa, 2019, When the mesh goes away: an analysis of poly-4-hydroxybutyrate mesh for complex hernia repair., Plast Reconstr Surg Glob Open, 7, e2576, 10.1097/GOX.0000000000002576 · DOI
  7. Christopher, 2021, Onlay poly-4-hydroxybutyrate (P4HB) mesh for complex hernia: early clinical and patient reported outcomes., J Surg Res, 264, 199, 10.1016/j.jss.2021.02.012 · DOI
  8. Levy, 2021, Poly-4-hydroxybutyrate (Phasix) mesh onlay in complex abdominal wall repair., Surg Endosc, 35, 2014, 10.1007/s00464-020-07601-9 · DOI · Paper page
  9. Buell, 2017, Initial experience with biologic polymer scaffold (poly-4-hydroxybuturate) in complex abdominal wall reconstruction., Ann Surg, 266, 185, 10.1097/SLA.0000000000001916 · DOI
  10. Rognoni, 2020, Clinical outcomes and quality of life associated with the use of a biosynthetic mesh for complex ventral hernia repair: analysis of the “Italian Hernia Club” registry., Sci Rep, 10, 10706, 10.1038/s41598-020-67821-w · DOI
  11. Pakula, 2020, Outcomes of open complex ventral hernia repairs with retromuscular placement of poly-4-hydroxybutyrate bioabsorbable mesh., Surg Innov, 27, 32, 10.1177/1553350619881066 · doi:10.1177/1553350619881066
  12. Mellia, 2020, Outcomes of poly-4-hydroxybutyrate mesh in ventral hernia repair: a systematic review and pooled analysis., Plast Reconstr Surg Glob Open, 8, e3158, 10.1097/GOX.0000000000003158 · DOI
  13. Mangram, 2014, Guideline for prevention of surgical site infection, 1999., Am J Infect Control, 20, 250
  14. von Elm, 2007, The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies., Lancet, 370, 1453, 10.1016/S0140-6736(07)61602-X · DOI · Paper page
  15. Dindo, 2004, Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey., Ann Surg, 240, 205, 10.1097/01.sla.0000133083.54934.ae · DOI · Paper page
  16. Burger, 2004, Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia., Ann Surg, 240, 578, 10.1097/01.sla.0000141193.08524.e7 · DOI · Paper page
  17. Kokotovic, 2016, Long-term recurrence and complications associated with elective incisional hernia repair., JAMA, 316, 1575, 10.1001/jama.2016.15217 · DOI · Paper page
  18. Buell, 2021, Long-term outcomes in complex abdominal wall reconstruction repaired with absorbable biologic polymer scaffold (poly-4-hydroxybutyrate)., Ann Surg, 1, 1
  19. Rosen, 2017, Multicenter, prospective, longitudinal study of the recurrence, surgical site infection, and quality of life after contaminated ventral hernia repair using biosynthetic absorbable mesh: the COBRA study., Ann Surg, 265, 205, 10.1097/SLA.0000000000001601 · DOI · Paper page
  20. Holihan, 2016, Mesh location in open ventral hernia repair: a systematic review and network meta-analysis., World J Surg, 40, 89, 10.1007/s00268-015-3252-9 · DOI · Paper page
  21. Otero, 2019, Laparoscopic hernia repair., Adv Surg, 53, 1, 10.1016/j.yasu.2019.04.001 · DOI
  22. Schlosser, 2020, Outcomes specific to patient sex after open ventral hernia repair., Surgery, 167, 614, 10.1016/j.surg.2019.11.016 · doi:10.1016/j.surg.2019.11.016

Cited by

See all 38

Metadata

Authors
Roth, J. S., Anthone, G. J., Selzer, D. J., Poulose, B. K., Pierce, R. A., Bittner, J. G., Hope, W. W., Dunn, R. M., Martindale, R. G., Goldblatt, M. I., Earle, D. B., Romanelli, J. R., Mancini, G. J., Greenberg, J. A., Linn, J. G., Parra-Davila, E., Sandler, B. J., Deeken, C. R., Badhwar, A., Salluzzo, J. L., & Voeller, G. R.
Affiliations
  • From the Department of Surgery, University of Kentucky Medical Center, Lexington, KY (Roth)
  • Department of Surgery, Methodist Health System, Omaha, NE (Anthone)
  • Department of Surgery, Indiana University School of Medicine, Indianapolis, IN (Selzer)
  • Center for Abdominal Core Health, Ohio State Wexner Medical Center, Columbus, OH (Poulose)
  • Department of Surgery, Vanderbilt University Medical Center, Nashville, TN (Pierce)
  • Department of Surgery, Saint Francis Hospital, Hartford, CT (Bittner)
  • Department of Surgery, New Hanover Regional Medical Center, Wilmington, NC (Hope)
  • Department of Surgery, University of Massachusetts Worcester, Worcester, MA (Dunn)
  • Department of Surgery, Oregon Health & Science University, Portland, OR (Martindale)
  • Department of Surgery, Medical College of Wisconsin, Inc, Milwaukee, WI (Goldblatt)
  • Department of Surgery, New England Hernia Center, Lowell, MA (Earle)
  • Department of Surgery, Baystate Medical Center, Springfield, MA (Romanelli)
  • Department of Surgery, University of Tennessee Health Science Center, Memphis, TN (Mancini, Voeller)
  • Department of Surgery, Board of Regents of the University of Wisconsin System, Madison, WI (Greenberg)
  • Department of Surgery, North Shore University Health System, Evanston, IL (Linn)
  • Department of Surgery, Celebration Health, Celebration, FL (Parra-Davila)
  • Department of Surgery, Regents of the University of California, San Diego, CA (Sandler)
  • Covalent Bio, LLC, St Louis, MO (Deeken)
  • BD Interventional (Surgery), Warwick, RI (Badhwar)
  • Department of Surgery, Virginia Commonwealth University, Richmond, VA (Salluzzo).
Venue
Journal of the American College of Surgeons
Published
2022-11-15
Volume
235
Issue
6
Pages
894-904
ISSN
1072-7515
Cited by
38
References
1
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long-Term, Prospective, Multicenter Study of Poly-4-Hydroxybutyrate Mesh (Phasix Mesh) for Hernia Repair in Cohort at Risk for Complication: 60-Month Follow-Up. https://app.cochat.ai/papers/10.1097/xcs.0000000000000363
The paper
Roth, J. S., Anthone, G. J., Selzer, D. J., Poulose, B. K., Pierce, R. A., Bittner, J. G., Hope, W. W., Dunn, R. M., Martindale, R. G., Goldblatt, M. I., Earle, D. B., Romanelli, J. R., Mancini, G. J., Greenberg, J. A., Linn, J. G., Parra-Davila, E., Sandler, B. J., Deeken, C. R., Badhwar, A., . . . Voeller, G. R. (2022). Long-Term, Prospective, Multicenter Study of Poly-4-Hydroxybutyrate Mesh (Phasix Mesh) for Hernia Repair in Cohort at Risk for Complication: 60-Month Follow-Up. Journal of the American College of Surgeons. https://doi.org/10.1097/xcs.0000000000000363

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.