The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Discrimination between ricin and sulphur mustard toxicity in vitro using Raman spectroscopy
Open accessAbstract
A Raman spectroscopy cell-based biosensor has been proposed for rapid detection of toxic agents, identification of the type of toxin and prediction of the concentration used. This technology allows the monitoring of the biochemical properties of living cells over long periods of time by measuring the Raman spectra of the cells non-invasively, rapidly and without use of labels (Notingher et al.2004 doi:10.1016/j.bios.2004.04.008). Here we show that this technology can be used to distinguish between changes induced in A549 lung cells by the toxin ricin and the chemical warfare agent sulphur mustard. A multivariate model based on principal component analysis (PCA) and linear discriminant analysis (LDA) was used for the analysis of the Raman spectra of the cells. The leave-one-out cross-validation of the PCA-LDA model showed that the damaged cells can be detected with high sensitivity (98.9%) and high specificity (87.7%). High accuracy in identifying the toxic agent was also found: 88.6% for sulphur mustard and 71.4% for ricin. The prediction errors were observed mostly for the ricin treated cells and the cells exposed to the lower concentration of sulphur mustard, as they induced similar biochemical changes, as indicated by cytotoxicity assays. The concentrations of sulphur mustard used were also identified with high accuracy: 93% for 200 μM and 500 μM, and 100% for 1000 μM. Thus, biological Raman microspectroscopy and PCA-LDA analysis not only distinguishes between viable and damaged cells, but can also discriminate between toxic challenges based on the cellular biochemical and structural changes induced by these agents and the eventual mode of cell death.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Herne, H., Cooley, W. W., & Lohnes, P. R. (1973) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344428 · Cited by 35,697
Wold, S., Esbensen, K., & Geladi, P. (1987) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(87)80084-9 · Cited by 11,606
Cross validatory choice and assessment of statistical predictions
Stone, M. (1974) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1974.tb00994.x · Cited by 10,881
Dunteman, G. (1989) · Sage eBooks · doi:10.4135/9781412985475 · Cited by 2,658
Studying single living cells and chromosomes by confocal Raman microspectroscopy
Puppels, G. J., de Mul, F. F. M., Otto, C., Greve, J., Robert-Nicoud, M., Arndt-Jovin, D. J., & Jovin, T. M. (1990) · Nature · doi:10.1038/347301a0 · Cited by 920
A morphological biosensor for mammalian cells
Giaever, I., & Keese, C. R. (1993) · Nature · doi:10.1038/366591a0 · Cited by 770
Infrared and Raman Spectroscopy of Biological Materials
Gremlich, H.-U., & Yan, B. (2000) · CRC Press eBooks · doi:10.1201/b16936 · Cited by 531
A new approach to neural cell culture for long-term studies
Potter, S. M., & DeMarse, T. B. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00412-5 · Cited by 489
Near‐infrared Raman spectroscopy for the classification of epithelial pre‐cancers and cancers
Stone, N., Kendall, C., Shepherd, N., Crow, P., & Barr, H. (2002) · Journal of Raman Spectroscopy · doi:10.1002/jrs.882 · Cited by 472
Raman spectroscopy in biology: Principles and applications
Tu, A. T. (1982) · Andalas University Repository (Andalas University) · Cited by 458
Tiruppathi, C., Malik, A. B., Del Vecchio, P. J., Keese, C. R., & Giaever, I. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.17.7919 · Cited by 433
Development and Application of Cell-Based Biosensors
Pancrazio, J. J., Whelan, J. P., Borkholder, D. A., Ma, W., & Stenger, D. A. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.225 · Cited by 391
The use of neuronal networks on multielectrode arrays as biosensors
Gross, G. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96931-n · Cited by 373
Nonresonant Confocal Raman Imaging of DNA and Protein Distribution in Apoptotic Cells
Uzunbajakava, N., Lenferink, A., Kraan, Y., Volokhina, E., Vrensen, G., Greve, J., & Otto, C. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75124-8 · Cited by 347
Discriminating Basal Cell Carcinoma from its Surrounding Tissue by Raman Spectroscopy
Bakker Schut, T. C., Caspers, P. J., Puppels, G. J., Nijssen, A., Heule, F., Neumann, M. H. A., & Hayes, D. P. (2002) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2002.01807.x · Cited by 346
Maquelin, K., Kirschner, C., Choo-Smith, L.-P., Ngo-Thi, N. A., van Vreeswijk, T., Stämmler, M., Endtz, H. P., Bruining, H. A., Naumann, D., & Puppels, G. J. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.1.324-329.2003 · Cited by 317
Spectroscopic study of human lung epithelial cells (A549) in culture: Living cells versus dead cells
Notingher, I., Verrier, S., Haque, S., Polak, J. M., & Hench, L. L. (2003) · Biopolymers · doi:10.1002/bip.10378 · Cited by 316
Self-citationMaquelin, K., Choo-Smith, L.-P., van Vreeswijk, T., Endtz, H. P., Smith, B., Bennett, R., Bruining, H. A., & Puppels, G. J. (2000) · Analytical Chemistry · doi:10.1021/ac991011h · Cited by 312
Haka, A. S., Shafer‐Peltier, K., Fitzmaurice, M., Crowe, J. P., Dasari, R. R., & Feld, M. S. (2002) · PubMed · Cited by 302
Shafer‐Peltier, K. E., Haka, A. S., Fitzmaurice, M., Crowe, J., Myles, J., Dasari, R. R., & Feld, M. S. (2002) · Journal of Raman Spectroscopy · doi:10.1002/jrs.877 · Cited by 270
Investigating Microbial (Micro)colony Heterogeneity by Vibrational Spectroscopy
Choo-Smith, L.-P., Maquelin, K., van Vreeswijk, T., Bruining, H. A., Puppels, G. J., Thi, N. A. N., Kirschner, C., Naumann, D., Ami, D., Villa, A. M., et al. (2001) · Applied and Environmental Microbiology · doi:10.1128/aem.67.4.1461-1469.2001 · Cited by 253
Kendall, C., Stone, N., Shepherd, N., Geboes, K., Warren, B., Bennett, R., & Barr, H. (2003) · The Journal of Pathology · doi:10.1002/path.1376 · Cited by 245
Raman Spectroscopy for Early Detection of Laryngeal Malignancy: Preliminary Results
Stone, N., Stavroulaki, P., Kendall, C., Birchall, M., & Barr, H. (2000) · The Laryngoscope · doi:10.1097/00005537-200010000-00037 · Cited by 228
Notingher, I., Bisson, I., Bishop, A. E., et al. (2004) · Analytical Chemistry · doi:10.1021/ac0498720 · Cited by 214
Self-citationThe use of Raman spectroscopy to identify and grade prostatic adenocarcinoma in vitro
Crow, P., Stone, N., Kendall, C. A., Uff, J. S., Farmer, J. A. M., Barr, H., & Wright, M. P. J. (2003) · British Journal of Cancer · doi:10.1038/sj.bjc.6601059 · Cited by 189
Technological advances in high-throughput screening
Fernandes, P. B. (1998) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(98)80089-6 · Cited by 170
Chiappalone, M., Vato, A., Tedesco, M., Marcoli, M., Davide, F., & Martinoia, S. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00041-1 · Cited by 131
Ziegler, C. (2000) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160051550 · Cited by 120
Neuronal networks for biochemical sensing
Gross, G. W., Rhoades, B. K., & Jordan, R. S. (1992) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(92)80022-p · Cited by 94
In situ non‐invasive spectral discrimination between bone cell phenotypes used in tissue engineering
Notingher, I., Jell, G., Lohbauer, U., Salih, V. M., & Hench, L. L. (2004) · Journal of Cellular Biochemistry · doi:10.1002/jcb.20136 · Cited by 94
Self-citationCharacterization of breast duct epithelia: a Raman spectroscopic study
Kneipp, J., Schut, T. C. B., Kliffen, M., Menke‐Pluijmers, M. B. E., & Puppels, G. J. (2003) · Vibrational Spectroscopy · doi:10.1016/s0924-2031(03)00048-1 · Cited by 73
Raman Spectral Mapping in the Assessment of Axillary Lymph Nodes in Breast Cancer
Smith, J., Kendall, C. A., Sammon, A. M., Christie-Brown, J., & Stone, N. (2003) · Technology in Cancer Research & Treatment · doi:10.1177/153303460300200407 · Cited by 69
Development of a Whole-Cell-Based Biosensor for Detecting Histamine as a Model Toxin
May, K. M. L., Wang, Y., Bachas, L. G., & Anderson, K. W. (2004) · Analytical Chemistry · doi:10.1021/ac049810+ · Cited by 61
Lorenzelli, L., Margesin, B., Sergio Martinoia, A., Tedesco, M., & Valle, M. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00040-x · Cited by 56
Evaluation of a high throughput toxicity biosensor and comparison with a Daphnia magna bioassay.
Kim, B., Park, K. S., Kim, S. D., & Gu, M. (2003) · Biosensors & bioelectronics · doi:10.1016/s0956-5663(03)00027-7 · Cited by 45
Cited by
Raman Spectroscopy of Biological Tissues
Movasaghi, Z., Rehman, S., & Rehman, I. U. (2007) · Applied Spectroscopy Reviews · doi:10.1080/05704920701551530 · Cited by 2,518
McDonagh, C., Burke, C. S., & MacCraith, B. D. (2008) · Chemical Reviews · doi:10.1021/cr068102g · Cited by 1,026
Raman Spectroscopy of Biological Tissues
Talari, A. C. S., Movasaghi, Z., Rehman, S., & Rehman, I. U. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.923902 · Cited by 739
Twenty-first century challenges for biomaterials
Hench, L. L., & Thompson, I. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0151.focus · Cited by 467
Self-citationRaman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Self-citation
Metadata
- Authors
- Notingher, I., Green, C., Dyer, C., Perkins, E., Hopkins, N., Lindsay, C., & Hench, L. L.
- Venue
- Journal of The Royal Society Interface
- Publisher
- The Royal Society
- Published
- 2004-11-22
- Volume
- 1
- Issue
- 1
- Pages
- 79-90
- ISSN
- 1742-5662 (ISSN-L)
- 1742-5689
- OpenAlex
- W2154743597
- Cited by
- 291
- References
- 35
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.