The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Hydrogel systems and their role in neural tissue engineering
Open accessAbstract
Neural tissue engineering (NTE) is a rapidly progressing field that promises to address several serious neurological conditions that are currently difficult to treat. Selecting the right scaffolding material to promote neural and non-neural cell differentiation as well as axonal growth is essential for the overall design strategy for NTE. Among the varieties of scaffolds, hydrogels have proved to be excellent candidates for culturing and differentiating cells of neural origin. Considering the intrinsic resistance of the nervous system against regeneration, hydrogels have been abundantly used in applications that involve the release of neurotrophic factors, antagonists of neural growth inhibitors and other neural growth-promoting agents. Recent developments in the field include the utilization of encapsulating hydrogels in neural cell therapy for providing localized trophic support and shielding neural cells from immune activity. In this review, we categorize and discuss the various hydrogel-based strategies that have been examined for neural-specific applications and also highlight their strengths and weaknesses. We also discuss future prospects and challenges ahead for the utilization of hydrogels in NTE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling physiological events in 2D vs. 3D cell culture
Duval, K., Grover, H., Han, L.-H., Mou, Y., Pegoraro, A. F., Fredberg, J., & Chen, Z. (2017) · Physiology · doi:10.1152/physiol.00036.2016 · Cited by 1,849 · cited 2×
“Cytoskeletal forces that govern the movement of neurites in a 2D system are drastically different from the forces experienced in a 3D culture system that leads to neuronal migration and maturation [39].”
BackgroundStretch-activated ion channel Piezo1 directs lineage choice in human neural stem cells
Pathak, M. M., Nourse, J. L., Tran, T., Hwe, J., Arulmoli, J., Le, D. T. T., Bernardis, E., Flanagan, L. A., & Tombola, F. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1409802111 · Cited by 657
Mechanically Activated Ion Channels
Ranade, S. S., Syeda, R., & Patapoutian, A. (2015) · Neuron · doi:10.1016/j.neuron.2015.08.032 · Cited by 652 · cited 1×
“Acid-sensing ion channels and transient receptor potential ion channels, particularly TRPV4, potassium ion channels with ‘two-pore domains’ such as the TWIK-1-related K channel (TREK-1), TREK-2, TWIK-related arachidonic acidstimulated K channel and Piezo ion channels, are among the few such ion channels associated wit…”
Extracellular Matrix: Functions in the Nervous System
Barros, C. S., Franco, S. J., & Muller, U. (2011) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a005108 · Cited by 506
Peripheral nerve conduits: technology update
Hasirci, V., Arslantunali, D., Dursun, T., Yucel, D., & Hasirci, N. (2014) · Medical Devices Evidence and Research · doi:10.2147/mder.s59124 · Cited by 224 · cited 1×
“Nerve conduits are made up of either biological or synthetic polymers such as collagen and gelatin or polyethylene glycol and polyvinyl alcohol polymers, respectively [96].”
BackgroundImproving peripheral nerve regeneration: From molecular mechanisms to potential therapeutic targets
Chan, K. M., Gordon, T., Zochodne, D. W., & Power, H. A. (2014) · Experimental Neurology · doi:10.1016/j.expneurol.2014.09.006 · Cited by 189 · cited 1×
“This growth-inhibitory environment is particularly apparent in the central nervous system, while the peripheral nervous system demonstrates comparatively better regenerative potential, mainly because of the lack of neural inhibitory factors [5].”
BackgroundApostolova, I., Irintchev, A., & Schachner, M. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.1526-06.2006 · Cited by 166 · cited 1×
“The inhibitory molecules produced from activated glia within the scar such as CSPGs [66], tenascin [67] or ephrin-B2 [68] greatly impede the regeneration process.”
Background
Cited by
El-Husseiny, H. M., Mady, E. A., Hamabe, L., Abugomaa, A., Shimada, K., Yoshida, T., Tanaka, T., Yokoi, A., Elbadawy, M., & Tanaka, R. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100186 · Cited by 533
Brown, M., Li, J., Moraes, C., Tabrizian, M., & Li-Jessen, N. Y. K. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121786 · Cited by 282
Rodrigues, R. O., Shin, S.-R., & Bañobre-López, M. (2024) · Journal of Nanobiotechnology · doi:10.1186/s12951-024-02720-0 · Cited by 44
Tan, X. H., Liu, L., Mitryashkin, A., Wang, Y., & Goh, J. C. H. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c00313 · Cited by 36
Metadata
- Authors
- Madhusudanan, P., Raju, G., & Shankarappa, S.
- Venue
- Journal of The Royal Society Interface
- Publisher
- The Royal Society
- Published
- 2020-01
- Volume
- 17
- Issue
- 162
- Pages
- 20190505
- ISSN
- 1742-5662 (ISSN-L)
- 1742-5689
- OpenAlex
- W2999401603
- Cited by
- 201
- References
- 7
- FWCI
- 7.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hydrogel systems and their role in neural tissue engineering. https://app.cochat.ai/papers/10.1098/rsif.2019.0505
- The paper
- Madhusudanan, P., Raju, G., & Shankarappa, S. (2020). Hydrogel systems and their role in neural tissue engineering. Journal of The Royal Society Interface. https://doi.org/10.1098/rsif.2019.0505
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.