Cited by 391

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Bionic ankle–foot prosthesis normalizes walking gait for persons with leg amputation

Herr, Hugh M., Grabowski, Alena M.·2012·Proceedings of the Royal Society B: Biological Sciences

Abstract

Over time, leg prostheses have improved in design, but have been incapable of actively adapting to different walking velocities in a manner comparable to a biological limb. People with a leg amputation using such commercially available passive-elastic prostheses require significantly more metabolic energy to walk at the same velocities, prefer to walk slower and have abnormal biomechanics compared with non-amputees. A bionic prosthesis has been developed that emulates the function of a biological ankle during level-ground walking, specifically providing the net positive work required for a range of walking velocities. We compared metabolic energy costs, preferred velocities and biomechanical patterns of seven people with a unilateral transtibial amputation using the bionic prosthesis and using their own passive-elastic prosthesis to those of seven non-amputees during level-ground walking. Compared with using a passive-elastic prosthesis, using the bionic prosthesis decreased metabolic cost by 8 per cent, increased trailing prosthetic leg mechanical work by 57 per cent and decreased the leading biological leg mechanical work by 10 per cent, on average, across walking velocities of 0.75–1.75 m s −1 and increased preferred walking velocity by 23 per cent. Using the bionic prosthesis resulted in metabolic energy costs, preferred walking velocities and biomechanical patterns that were not significantly different from people without an amputation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1098/rspb.2011.1194

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 45

  1. Donelan J. M., 2002, Mechanical work for step-to-step transitions is a major determinant of the metabolic cost of human walking, J. Exp. Biol., 205, 3717, 10.1242/jeb.205.23.3717 · DOI · Paper page
  2. 10.1152/japplphysiol.00734 · DOI
  3. 10.1097/00003677-200504000-00006 · DOI · Paper page
  4. 10.1007/BF00699624 · DOI
  5. Winter D. A., 1983, Energy generation and absorption at the ankle and knee during fast, natural, and slow cadences, Clin. Ortho. Rel. Res., 175, 147, 10.1097/00003086-198305000-00021 · DOI
  6. 10.1242/jeb.044214 · DOI
  7. 10.1242/jeb.003970 · DOI
  8. 10.1016/j.jbiomech.2004.01.017 · DOI
  9. 10.1097/00008526-200203000-00003 · DOI
  10. 10.1016/j.apmr.2006.06.013 · DOI
  11. 10.1016/j.jbiomech.2006.07.009 · DOI
  12. 10.1016/j.apmr.2005.07.310 · DOI
  13. Torburn L., 1995, Energy-expenditure during ambulation in dysvascular and traumatic below-knee amputees: a comparison of 5 prosthetic feet, J. Rehabil. Res. Dev., 32, 111
  14. 10.1016/S0966-6362(99)00009-0 · DOI
  15. 10.1007/s00421-008-0764-0 · DOI
  16. 10.2522/ptj.20090125 · DOI
  17. 10.1109/ICMA.2006.257781 · DOI
  18. 10.1115/1.3005335 · DOI
  19. 10.1371/journal.pone.0009307 · DOI
  20. 10.1080/00222895.1983.10735302 · DOI
  21. Palmer M. L.. 2002 Sagittal plane characterization of normal human ankle function across a range of walking speeds. Masters thesis Massachusetts Institute of Technology MA USA.
  22. 10.1016/0021-9290(83)90067-2 · DOI
  23. Versluys R., 2007, Presented at the 12th World Congr. Int. Soc. Prosthet. Orthot.
  24. 10.1109/ICORR.2005.1501123 · DOI
  25. Au S. K., 2006, Presented at Dyn. Walking: Mech. Control Hum. Robot. Locomotion
  26. 10.1109/ICORR.2007.4428441 · DOI
  27. 10.1109/IEMBS.2007.4352965 · DOI
  28. Herr H., 2007, Proc. Biomech. Lower Limb Health, Dis. Rehabil., 72
  29. 10.1109/MRA.2008.927697 · DOI
  30. Au S. K.. 2009 A powered ankle-foot prosthesis that improves transtibital amputee ambulation. PhD thesis Massachusetts Institute of Technology Cambridge MA.
  31. 10.1115/DETC2007-34512 · DOI
  32. 10.1109/TRO.2008.2008747 · DOI
  33. 10.1109/TNSRE.2009.2039620 · DOI
  34. 10.1089/rstb.2010.0347 · DOI
  35. 10.1016/S0966-6362(97)01112-0 · DOI
  36. 10.1016/j.apmr.2007.03.016 · DOI
  37. Kandel E. R., 2000, Principles of neural science
  38. Centers for Medicare and Medicaid Services, 2001, US Department of Health and Human Services. HCFA Common Procedure Coding System (HCPCS)
  39. Brockway J. M., 1987, Derivation of formulae used to calculate energy expenditure in man, Hum. Nutr. Clin. Nutr., 41, 463
  40. 10.1016/S0021-9290(01)00169-5 · DOI
  41. 10.1152/jappl.1975.39.1.174 · DOI
  42. 10.2522/ptj.20060035 · DOI
  43. 10.1016/S0966-6362(02)00069-3 · DOI
  44. 10.1016/S0966-6362(03)00062-6 · DOI
  45. 10.1016/j.jbiomech.2010.08.015 · DOI

Cited by

Sorted by citations

See all 391

Metadata

Authors
Herr, H. M., & Grabowski, A. M.
Venue
Proceedings of the Royal Society B: Biological Sciences
Published
2011-07-13
Volume
279
Issue
1728
Pages
457-464
ISSN
  • 0962-8452
  • 1471-2954
Cited by
391
References
1
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review