CoChat

Considering discrepancy when calibrating a mechanistic electrophysiology model

Lei, Chon Lok, Ghosh, Sanmitra, Whittaker, Dominic G., Aboelkassem, Yasser, Beattie, Kylie A., Cantwell, Chris D., Delhaas, Tammo, Houston, Charles, Novaes, Gustavo Montes, Panfilov, Alexander V., Pathmanathan, Pras, Riabiz, Marina, dos Santos, Rodrigo Weber, Walmsley, John, Worden, Keith, Mirams, Gary R., Wilkinson, Richard D. · 2020 · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Cited by 54

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Uncertainty quantification (UQ) is a vital step in using mathematical models and simulations to take decisions. The field of cardiac simulation has begun to explore and adopt UQ methods to characterize uncertainty in model inputs and how that propagates through to outputs or predictions; examples of this can be seen in the papers of this issue. In this review and perspective piece, we draw attention to an important and under-addressed source of uncertainty in our predictions—that of uncertainty in the model structure or the equations themselves. The difference between imperfect models and reality is termed model discrepancy , and we are often uncertain as to the size and consequences of this discrepancy. Here, we provide two examples of the consequences of discrepancy when calibrating models at the ion channel and action potential scales. Furthermore, we attempt to account for this discrepancy when calibrating and validating an ion channel model using different methods, based on modelling the discrepancy using Gaussian processes and autoregressive-moving-average models, then highlight the advantages and shortcomings of each approach. Finally, suggestions and lines of enquiry for future work are provided. This article is part of the theme issue ‘Uncertainty quantification in cardiac and cardiovascular modelling and simulation’.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1098/rsta.2019.0349

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Research works printed but not linked: 63

  1. 10.1113/jphysiol.2011.224238 · DOI · Paper page
  2. 10.1098/rspb.1992.0150 · DOI
  3. 10.1161/01.CIR.91.9.2454 · DOI
  4. 10.1113/expphysiol.2008.044099 · DOI · Paper page
  5. 10.1016/j.pbiomolbio.2010.03.002 · DOI · Paper page
  6. 10.1016/j.ahj.2013.11.004 · DOI · Paper page
  7. 10.1098/rsfs.2010.0041 · DOI
  8. 10.1016/j.media.2011.07.003 · DOI · Paper page
  9. 10.1111/j.1476-5381.2012.02020.x · DOI
  10. 10.1038/s41569-018-0104-y · DOI · Paper page
  11. 10.1002/cpt.1184 · DOI · Paper page
  12. 10.1113/JP271671 · DOI
  13. 10.1371/journal.pone.0114494 · DOI
  14. 10.3389/fphys.2013.00358 · DOI · Paper page
  15. 10.1002/cnm.2615 · DOI · Paper page
  16. 10.3389/fphys.2019.00721 · DOI · Paper page
  17. 10.1080/01621459.2015.1119695 · DOI
  18. 10.1080/01621459.2016.1211016 · DOI · Paper page
  19. Dashti M Stuart AM. 2017 The Bayesian approach to inverse problems pp. 311–428. Springer International Publishing. · DOI · Paper page
  20. 10.1201/b16018 · doi:10.1201/b16018 · Paper page
  21. 10.1016/j.bpj.2019.07.029 · DOI
  22. 10.1088/0266-5611/30/11/114007 · DOI · Paper page
  23. 10.1152/ajpheart.00794.2003 · DOI · Paper page
  24. 10.1016/j.pbiomolbio.2007.07.011 · DOI
  25. 10.1371/journal.pone.0107984 · DOI
  26. 10.1371/journal.pcbi.1004242 · DOI
  27. 10.1016/j.yjmcc.2015.11.018 · DOI
  28. 10.3389/fphys.2017.00986 · DOI
  29. 10.1371/journal.pone.0225245 · DOI
  30. Hansen N. 2006 The CMA evolution strategy: a comparing review pp. 75–102. Berlin Heidelberg: Springer. · DOI · Paper page
  31. 10.5334/jors.252 · DOI
  32. 10.1016/j.pbiomolbio.2015.12.008 · DOI
  33. Van der Vaart AW, 2000, Asymptotic statistics
  34. Bernardo JM, 2009, Bayesian theory
  35. 10.1214/009053606000000029 · DOI
  36. De Blasi P, 2013, Bayesian asymptotics with misspecified models, Stat. Sinica, 23, 169
  37. 10.1113/JP275733 · DOI
  38. 10.1046/j.1540-8167.2002.01131.x · DOI
  39. 10.1152/ajpheart.00511.2012 · DOI · Paper page
  40. 10.1016/j.bpj.2019.07.030 · DOI
  41. Rasmussen C, 2006, Gaussian processes for machine learning
  42. Quiñonero-Candela J, 2005, A unifying view of sparse approximate gaussian process regression, J. Mach. Learn. Res., 6, 1939
  43. Theano Development Team. 2016 Theano: A Python framework for fast computation of mathematical expressions. (http://arxiv.org/abs/1605.02688) · arXiv
  44. Seabold S Perktold J. 2010 Statsmodels: econometric and statistical modeling with python. In Proc. of the 9th Python in Science Conf. vol. 57 p. 61 Scipy. · DOI · Paper page
  45. Whittaker DG, 2020, Calibration of ionic and cellular cardiac electrophysiology models, WIREs Systems Biol. Med., 1482
  46. 10.1016/j.pbiomolbio.2018.05.011 · DOI
  47. Hoeting JA, 1999, Bayesian model averaging: a tutorial, Stat. Sci., 14, 382
  48. 10.1098/rsta.2012.0388 · DOI
  49. 10.1080/01621459.2013.802963 · DOI
  50. 10.1098/rsta.2019.0348 · DOI
  51. 10.1140/epjst/e2009-01087-5 · DOI
  52. 10.1111/rssc.12222 · DOI
  53. 10.1007/s13253-011-0077-3 · DOI
  54. Frigola R Lindsten F Schön TB Rasmussen CE. 2013 Bayesian inference and learning in Gaussian process state-space models with particle MCMC. In Advances in neural information processing systems 26 pp. 3156–3164. Red Hook NY: Curran Associates.
  55. 10.1016/j.ymssp.2017.09.032 · DOI
  56. Meeds T Roeder G Grant P Phillips A Dalchau N. 2019 Efficient amortised bayesian inference for hierarchical and nonlinear dynamical systems. In Int. Conf. on Machine Learning pp. 4445–4455. Long Beach CA: PMLR.
  57. Ryder T Golightly A McGough AS Prangle D. 2018 Black-box variational inference for stochastic differential equations. (http://arxiv.org/abs/1802.03335) · arXiv
  58. 10.1201/9781315117195 · DOI · Paper page
  59. Craig PS Goldstein M Seheult AH Smith JA. 1997 Pressure matching for hydrocarbon reservoirs: a case study in the use of bayes linear strategies for large computer experiments. In Case studies in Bayesian statistics pp. 37–93 New York NY: Springer. · DOI · Paper page
  60. 10.1198/016214501753168370 · DOI · Paper page
  61. Holden PB, 2018, ABC for climate: dealing with expensive simulators, Handbook of approximate Bayesian computation, 569, 10.1201/9781315117195-19 · DOI
  62. Novaes GM Campos JO Alvarez-Lacalle E Muñoz SA Rocha BM dos Santos RW. 2019 Combining polynomial chaos expansions and genetic algorithm for the coupling of electrophysiological models. In Computational Science – ICCS 2019 Lecture Notes in Computer Science vol. 11538 pp. 116–129 New York NY: Springer. · doi:10.1007/978-3-030-22744-9_9
  63. 10.1098/rsta.2019.0335 · DOI

Cited by

See all 54

Metadata

Authors
Lei, C. L., Ghosh, S., Whittaker, D. G., Aboelkassem, Y., Beattie, K. A., Cantwell, C. D., Delhaas, T., Houston, C., Novaes, G. M., Panfilov, A. V., Pathmanathan, P., Riabiz, M., dos Santos, R. W., Walmsley, J., Worden, K., Mirams, G. R., & Wilkinson, R. D.
Affiliations
  • Computational Biology and Health Informatics, Department of Computer Science, University of Oxford, Oxford, UK
  • MRC Biostatistics Unit, University of Cambridge, Cambridge, UK
  • Centre for Mathematical Medicine and Biology, School of Mathematical Sciences, University of Nottingham, Nottingham, UK
  • Department of Bioengineering, University of California San Diego, La Jolla, CA, USA
  • Systems Modeling and Translational Biology, GlaxoSmithKline R&D, Stevenage, UK
  • ElectroCardioMaths Programme, Centre for Cardiac Engineering, Imperial College London, London, UK
  • CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
  • Graduate Program in Computational Modeling, Universidade Federal de Juiz de Fora, Juiz de Fora, Brazil
  • Department of Physics and Astronomy, Ghent University, Ghent, Belgium
  • US Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories, Silver Spring, MD, USA
  • Department of Biomedical Engineering King’s College London and Alan Turing Institute, London, UK
  • James T. Willerson Center for Cardiovascular Modeling and Simulation, Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX, USA
  • Dynamics Research Group, Department of Mechanical Engineering, University of Sheffield, Sheffield, UK
  • School of Mathematics and Statistics, University of Sheffield, Sheffield, UK
Venue
Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Published
2020-05-25
Volume
378
Issue
2173
Pages
20190349
ISSN
  • 1364-503X
  • 1471-2962
Cited by
54
References
12
Language
en
Licence
Funders
  • Wellcome Trust (101222/Z/13/Z, 212203/Z/18/Z)
  • British Heart Foundation (PG/15/59/31621, RE/13/4/30184, SP/18/6/33805)
  • Russian Foundation for Basic Research (18-29-13008)
  • Engineering and Physical Sciences Research Council (EP/L016044/1, EP/P010741/1, EP/R003645/1, EP/R006768/1, EP/R014604/1)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Considering discrepancy when calibrating a mechanistic electrophysiology model. https://app.cochat.ai/papers/10.1098/rsta.2019.0349
The paper
Lei, C. L., Ghosh, S., Whittaker, D. G., Aboelkassem, Y., Beattie, K. A., Cantwell, C. D., Delhaas, T., Houston, C., Novaes, G. M., Panfilov, A. V., Pathmanathan, P., Riabiz, M., dos Santos, R. W., Walmsley, J., Worden, K., Mirams, G. R., & Wilkinson, R. D. (2020). Considering discrepancy when calibrating a mechanistic electrophysiology model. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences. https://doi.org/10.1098/rsta.2019.0349

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.