Static properties of a non-neutral9Be+-ion plasma
The DOI matches its Crossref record.
Abstract
We report measurements of the static properties of laser-cooled non-neutral $^{9}\mathrm{Be}^{+}$-ion plasmas stored in Penning traps under a variety of experimental conditions. We have measured the shape, rotation frequency, density, and temperature of the ions as functions of the Penning-trap potential and laser-cooling configuration. Two different traps were used. In one trap, we were able to measure the ion temperature in directions both perpendicular and parallel to the trap magnetic field. In the other trap, $^{198}\mathrm{Hg}^{+}$ ions were stored simultaneously with the $^{9}\mathrm{Be}^{+}$ ions and their effect on the $^{9}\mathrm{Be}^{+}$ ions was measured. The experimental measurements are compared with theoretical predictions. Within experimental error, the ion plasmas rotate without shear and exhibit approximate thermal equilibrium. For a single stored species, a static model of the ion plasmas, based on thermal equilibrium, is formulated. When the ion-plasma dimensions are small compared to the trap dimensions, this model predicts that the ion plasmas are spheroidal and have an aspect ratio which is a function of the plasma rotation frequency, and the single-particle cyclotron and axial frequencies. This is verified by measurement. The ion densities and temperatures measured in our experiments show that the plasmas are strongly coupled and should exhibit liquid and solid properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Itano, W. M., Heinzen, D. J., Bollinger, J. J., & Wineland, D. J. (1990) · Physical Review A · doi:10.1103/physreva.41.2295 · Cited by 1,180
Self-citationTrapped nonneutral plasmas, liquids, and crystals (the thermal equilibrium states)
Dubin, D. H. E., & O’Neil, T. M. (1999) · Reviews of Modern Physics · doi:10.1103/revmodphys.71.87 · Cited by 717
Optimized dynamical decoupling in a model quantum memory
Biercuk, M. J., Uys, H., VanDevender, A. P., Shiga, N., Itano, W. M., & Bollinger, J. J. (2009) · Nature · doi:10.1038/nature07951 · Cited by 654
Self-citationQuantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Self-citationQuadrupole excitation of stored ion motion at the true cyclotron frequency
König, M., Bollen, G., Kluge, H.-J., Otto, T., & Szerypo, J. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04146-c · Cited by 495
Bollen, G., Becker, S., Kluge, H.-J., König, M., Moore, R. B., Otto, T., Raimbault-Hartmann, H., Savard, G., Schweikhard, L., & Stolzenberg, H. (1996) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(95)00561-7 · Cited by 241
Ultrasensitive detection of force and displacement using trapped ions
Biercuk, M. J., Uys, H., Britton, J. W., VanDevender, A. P., & Bollinger, J. J. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.165 · Cited by 180
“Our system is a crystal of (9)Be ions in a Penning trap [11, 12, 23].”
BackgroundMethodSelf-citationA 303-MHz frequency standard based on trapped Be/sup +/ ions
Bollinger, J. J., Heizen, D. J., Itano, W. M., Gilbert, S. L., & Wineland, D. J. (1991) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1990.1032897 · Cited by 169
Self-citationTest of the linearity of quantum mechanics by rf spectroscopy of theBe+9ground state
Bollinger, J. J., Heinzen, D. J., Itano, W. M., Gilbert, S. L., & Wineland, D. J. (1989) · Physical Review Letters · doi:10.1103/physrevlett.63.1031 · Cited by 151
Self-citationItano, W. M., Bergquist, J. C., Bollinger, J. J., & Wineland, D. J. (1995) · Physica Scripta · doi:10.1088/0031-8949/1995/t59/013 · Cited by 118
Self-citationPrecise control of the global rotation of strongly coupled ion plasmas in a Penning trap
Huang, X.-P., Bollinger, J. J., Mitchell, T. B., Itano, W. M., & Dubin, D. H. E. (1998) · Physics of Plasmas · doi:10.1063/1.872834 · Cited by 62
Self-citationDiamagnetic correction to the9Be+ground-state hyperfine constant
Shiga, N., Itano, W. M., & Bollinger, J. J. (2011) · Physical Review A · doi:10.1103/physreva.84.012510 · Cited by 30
Self-citation
Metadata
- Authors
- Brewer, L. R., Prestage, J. D., Bollinger, J. J., Itano, W. M., Larson, D. J., & Wineland, D. J.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 1988-07-01
- Volume
- 38
- Issue
- 2
- Pages
- 859-873
- ISSN
- 0556-2791 (ISSN-L)
- OpenAlex
- W2053319112
- Cited by
- 139
- References
- 0
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.