Evaluation of systematic shifts of the88Sr+single-ion optical frequency standard at the10−17level
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
An ion trap of the end-cap design was built recently at the National Research Council of Canada for improved control of the ${}^{88}$Sr${}^{+}$ single-ion optical frequency standard systematic shifts. The uncertainty on the micromotion-induced shifts is smaller by more than four orders of magnitude when compared to our previous trap system and reaches a fractional frequency uncertainty of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. To obtain this low uncertainty level, the micromotion is minimized with trim electrodes and the trap is operated at a special frequency at which there is anticorrelation between the second-order Doppler and Stark shifts. This choice of operating frequency, determined by the differential scalar polarizability of the clock transition, yields a suppression by a factor of $\ensuremath{\approx}$28 in the combined micromotion shifts. Like many optical frequency standards, the dominant source of uncertainty in the new trap is the blackbody radiation shift. Its uncertainty has been reduced by an order of magnitude with a recent theoretical evaluation of the differential scalar polarizability of the clock transition. The fractional blackbody shift uncertainty, estimated using a model of the blackbody field at the ion, is $2.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$. The otherwise dominant electric quadrupole shift is reduced to below the $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$ level with a cancellation method based on the average frequency of several pairs of Zeeman components. This method also cancels the tensor Stark shift and simplifies the description of the frequency shifts that are quantization-axis dependent. This paper provides a detailed description of the ${}^{88}$Sr${}^{+}$ optical frequency standard uncertainty evaluation and the methods used to make the standard robust against changes in the trap environment. The total fractional frequency uncertainty of the ${}^{88}$Sr${}^{+}$ ion for our current system is estimated at $2.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$. We also discuss the uncertainty evaluation of a recently reported measurement of the ${}^{88}$Sr${}^{+}$ $S$-$D$ clock transition made over a 2-month period by comparison with a maser referenced to the SI second. The frequency measured is $444\phantom{\rule{0.16em}{0ex}}779\phantom{\rule{0.16em}{0ex}}044\phantom{\rule{0.16em}{0ex}}095\phantom{\rule{0.16em}{0ex}}485.5(9)$ Hz, with an uncertainty limited by the evaluation of the maser frequency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Laser cooling below the Doppler limit by polarization gradients: simple theoretical models
Dalibard, J., & Cohen-Tannoudji, C. (1989) · Journal of the Optical Society of America B · doi:10.1364/josab.6.002023 · Cited by 1,270
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Ma, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566
Making optical atomic clocks more stable with 10−16-level laser stabilization
Jiang, Y. Y., Ludlow, A. D., Lemke, N. D., Fox, R. W., Sherman, J. A., Ma, L.-S., & Oates, C. W. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.313 · Cited by 462
NIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Hite, D. A., Colombe, Y., Wilson, A. C., Brown, K. R., Warring, U., Jördens, R., Jost, J. D., McKay, K. S., Pappas, D. P., Leibfried, D., et al. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.103001 · Cited by 176
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Highly charged ions: Optical clocks and applications in fundamental physics
Kozlov, M. G., Safronova, M. S., Crespo López-Urrutia, J. R., & Schmidt, P. O. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.045005 · Cited by 311
Optical clock comparison for Lorentz symmetry testing
Sanner, C., Huntemann, N., Lange, R., Tamm, C., Peik, E., Safronova, M. S., & Porsev, S. G. (2019) · Nature · doi:10.1038/s41586-019-0972-2 · Cited by 275
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Metadata
- Authors
- Dubé, P., Madej, A. A., Zhou, Z., & Bernard, J. E.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2013-02-07
- Volume
- 87
- Issue
- 2
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W2319993681
- Cited by
- 127
- References
- 9
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.