Agreement between two88Sr+optical clocks to 4 parts in 1017
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The frequencies of two nominally identical ${}^{88}{\mathrm{Sr}}^{+}$ trapped single ion optical clocks, based on the 674 nm 5$s$ ${}^{2}$${S}_{1/2}$--4$d$ ${}^{2}$${D}_{5/2}$ electric quadrupole clock transition, have been compared over a period of nine months. The frequencies of the two clocks were found to agree within a total uncertainty of 4 \ifmmode\times\else\texttimes\fi{} 10${}^{\ensuremath{-}17}$, demonstrating that the individual ${}^{88}{\mathrm{Sr}}^{+}$ optical clocks are reproducible at the 3 \ifmmode\times\else\texttimes\fi{} 10${}^{\ensuremath{-}17}$ level. The absolute frequency of the clock transition was measured to be $f$ = 444 779 044 095 486.71(24) Hz using an optical frequency comb referenced to a cesium fountain primary frequency standard. The standard uncertainty of 0.24 Hz (5.3 \ifmmode\times\else\texttimes\fi{} 10${}^{\ensuremath{-}16}$ of the optical frequency) is dominated by measurement statistics and cesium fountain systematics and is around four times lower than previously published.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Self-citationGodun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationSub-hertz fundamental linewidth photonic integrated Brillouin laser
Gundavarapu, S., Brodnik, G. M., Puckett, M., Huffman, T., Bose, D., Behunin, R., Wu, J., Qiu, T., Pinho, C., Chauhan, N., et al. (2019) · Nature Photonics · doi:10.1038/s41566-018-0313-2 · Cited by 426
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“…lattice clocks to take advantage of the high stability of a lattice clock to correct phase excursions of the laser (Hume and Leibrandt 2016) The et al 2004, 2012, Margolis et al 2004, Dub é et al 2013, 2017, Barwood et al 2014) have also been investigated by several groups as frequency standards.”
Influential
Metadata
- Authors
- Barwood, G. P., Huang, G., Klein, H. A., Johnson, L. A. M., King, S. A., Margolis, H. S., Szymaniec, K., & Gill, P.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2014-05-27
- Volume
- 89
- Issue
- 5
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W2332927447
- Cited by
- 90
- References
- 2
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Agreement between two88Sr+optical clocks to 4 parts in 1017. https://app.cochat.ai/papers/10.1103/physreva.89.050501
- The paper
- Barwood, G. P., Huang, G., Klein, H. A., Johnson, L. A. M., King, S. A., Margolis, H. S., Szymaniec, K., & Gill, P. (2014). Agreement between two88Sr+optical clocks to 4 parts in 1017. Physical Review A. https://doi.org/10.1103/physreva.89.050501
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.