CoChat

Agreement between two88Sr+optical clocks to 4 parts in 1017

Barwood, G. P., Huang, G., Klein, H. A., Johnson, L. A. M., King, S. A., Margolis, H. S., Szymaniec, K., Gill, P. · 2014 · Physical Review A
Cited by 90

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The frequencies of two nominally identical ${}^{88}{\mathrm{Sr}}^{+}$ trapped single ion optical clocks, based on the 674 nm 5$s$ ${}^{2}$${S}_{1/2}$--4$d$ ${}^{2}$${D}_{5/2}$ electric quadrupole clock transition, have been compared over a period of nine months. The frequencies of the two clocks were found to agree within a total uncertainty of 4 \ifmmode\times\else\texttimes\fi{} 10${}^{\ensuremath{-}17}$, demonstrating that the individual ${}^{88}{\mathrm{Sr}}^{+}$ optical clocks are reproducible at the 3 \ifmmode\times\else\texttimes\fi{} 10${}^{\ensuremath{-}17}$ level. The absolute frequency of the clock transition was measured to be $f$ = 444 779 044 095 486.71(24) Hz using an optical frequency comb referenced to a cesium fountain primary frequency standard. The standard uncertainty of 0.24 Hz (5.3 \ifmmode\times\else\texttimes\fi{} 10${}^{\ensuremath{-}16}$ of the optical frequency) is dominated by measurement statistics and cesium fountain systematics and is around four times lower than previously published.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physreva.89.050501

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Barwood, G. P., Huang, G., Klein, H. A., Johnson, L. A. M., King, S. A., Margolis, H. S., Szymaniec, K., & Gill, P.
Venue
Physical Review A
Published
2014-05-27
Volume
89
Issue
5
ISSN
  • 0556-2791 (ISSN-L)
  • 1050-2947
  • 1094-1622
OpenAlex
W2332927447
Cited by
90
References
3
FWCI
6.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.