Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 769

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Interpretation of infrared and Raman spectra of amorphous carbon nitrides

Ferrari, A. C., Rodil, S. E., Robertson, J.·2003·Physical Review B

Abstract

A general framework for the interpretation of infrared and Raman spectra of amorphous carbon nitrides is presented. In the first part of this paper we examine the infrared spectra. The peaks around 1350 and 1550 ${\mathrm{cm}}^{\mathrm{\ensuremath{-}}1}$ found in the infrared spectrum of amorphous carbon nitride or hydrogenated and hydrogen-free amorphous carbon are shown to originate from the large dynamic charge of the more delocalized \ensuremath{\pi} bonding which occurs in more ${\mathrm{sp}}^{2}$ bonded networks. The IR absorption decreases strongly when the \ensuremath{\pi} bonding becomes localized, as in tetrahedral amorphous carbon. Isotopic substitution is used to assign the modes to $\mathrm{C}=\mathrm{C}$ skeleton modes, even those modes around 1600 ${\mathrm{cm}}^{\mathrm{\ensuremath{-}}1}$ which become strongly enhanced by the presence of hydrogen. The infrared spectrum of carbon nitride may resemble the Raman spectrum at some excitation energy, but the infrared activity does not primarily result from nitrogen breaking the symmetry. In the second part we examine the Raman spectra. A general model is presented for the interpretation of the Raman spectra of amorphous carbon nitrides measured at any excitation energy. The Raman spectra can be explained in terms of an amorphous carbon based model, without need of extra peaks due to CN, NN, or NH modes. We classify amorphous carbon nitride films in four classes, according to the corresponding N-free film: $a\ensuremath{-}\mathrm{C}:\mathrm{N},$ $a\ensuremath{-}\mathrm{C}:\mathrm{H}:\mathrm{N},$ $ta\ensuremath{-}\mathrm{C}:\mathrm{H}:\mathrm{N},$ and $ta\ensuremath{-}\mathrm{C}:\mathrm{N}.$ We analyze a wide variety of samples for the four classes and present the Raman spectra as a function of N content, ${\mathrm{sp}}^{3}$ content, and band gap. In all cases, a multiwavelength Raman study allows a direct correlation of the Raman parameters with the N content, which is not generally possible for single wavelength excitation. The G peak dispersion emerges as a most informative parameter for Raman analysis. UV Raman enhances the ${\mathrm{sp}}^{1}$ CN peak, which is usually too faint to be seen in visible excitation. As for N-free samples, UV Raman also enhances the C-C ${\mathrm{sp}}^{3}$ bonds vibrations, allowing the ${\mathrm{sp}}^{3}$ content to be quantified.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevb.67.155306

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 769

Metadata

Authors
Ferrari, A. C., Rodil, S. E., & Robertson, J.
Venue
Physical Review B
Published
2003-04-09
Volume
67
Issue
15
ISSN
  • 0163-1829 (ISSN-L)
  • 1095-3795
OpenAlex
W2085168268
Cited by
769
References
24
FWCI
13.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interpretation of infrared and Raman spectra of amorphous carbon nitrides. https://app.cochat.ai/papers/10.1103/physrevb.67.155306
The paper
Ferrari, A. C., Rodil, S. E., & Robertson, J. (2003). Interpretation of infrared and Raman spectra of amorphous carbon nitrides. Physical Review B. https://doi.org/10.1103/physrevb.67.155306

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.