Extracting dark matter signatures from atomic clock stability measurements
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
We analyze possible effects of the dark matter environment on the atomic clock stability measurements. The dark matter is assumed to exist in the form of waves of ultralight scalar fields or in the form of topological defects (monopoles and strings). We identify dark matter signal signatures in clock Allan deviation plots that can be used to constrain the dark matter coupling to the Standard Model fields. The existing data on the ${\mathrm{Al}}^{+}/{\mathrm{Hg}}^{+}$ clock comparison are used to put new limits on the dilaton dark matter in the region of masses ${m}_{\ensuremath{\phi}}>{10}^{\ensuremath{-}15}\text{ }\text{ }\mathrm{eV}$. We also estimate the sensitivities of future atomic clock experiments in space, including the cesium microwave and strontium optical clocks aboard the International Space Station, as well as a potential nuclear clock. These experiments are expected to put new limits on the topological dark matter in the range of masses ${10}^{\ensuremath{-}10}\text{ }\text{ }\mathrm{eV}<{m}_{\ensuremath{\phi}}<{10}^{\ensuremath{-}6}\text{ }\text{ }\mathrm{eV}$.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Handbook of frequency stability analysis
Riley, W. J., & Riley, W. J. (2008) · doi:10.6028/nist.sp.1065 · Cited by 586
Hunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522
Searching for dilaton dark matter with atomic clocks
Arvanitaki, A., Huang, J., & Van Tilburg, K. (2015) · Physical Review D · doi:10.1103/physrevd.91.015015 · Cited by 404
Ultrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Single-Ion Nuclear Clock for Metrology at the 19th Decimal Place
Campbell, C. J., Radnaev, A. G., Kuzmich, A., Dzuba, V. A., Flambaum, V. V., & Derevianko, A. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.120802 · Cited by 347
Search for Ultralight Scalar Dark Matter with Atomic Spectroscopy
Van Tilburg, K., Leefer, N., Bougas, L., & Budker, D. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.011802 · Cited by 253
Experimental constraint on dark matter detection with optical atomic clocks
Wcisło, P., Morzyński, P., Bober, M., Cygan, A., Lisak, D., Ciuryło, R., & Zawada, M. (2016) · Nature Astronomy · doi:10.1038/s41550-016-0009 · Cited by 116
Comparing a mercury optical lattice clock with microwave and optical frequency standards
Tyumenev, R., Favier, M., Bilicki, S., Bookjans, E., Targat, R. L., Lodewyck, J., Nicolodi, D., Coq, Y. L., Abgrall, M., Guéna, J., et al. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/11/113002 · Cited by 85
Testing long-distance modifications of gravity to 100 astronomical units
Buscaino, B., DeBra, D., Graham, P. W., Gratta, G., & Wiser, T. D. (2015) · Physical Review D · doi:10.1103/physrevd.92.104048 · Cited by 19
Cited by
Search for domain wall dark matter with atomic clocks on board global positioning system satellites
Roberts, B. M., Blewitt, G., Dailey, C., Murphy, M., Pospelov, M., Rollings, A., Sherman, J., Williams, W., & Derevianko, A. (2017) · Nature Communications · doi:10.1038/s41467-017-01440-4 · Cited by 143
Fundamental constants: from measurement to the universe, a window on gravitation and cosmology
Uzan, J.-P. (2025) · Living Reviews in Relativity · doi:10.1007/s41114-025-00059-y · Cited by 36
Cosmologically varying kinetic mixing
Gan, X., & Liu, D. (2023) · Journal of High Energy Physics · doi:10.1007/jhep11(2023)031 · Cited by 20
MICROSCOPE’s view at gravitation
Bergé, J. (2023) · Reports on Progress in Physics · doi:10.1088/1361-6633/acd203 · Cited by 12
Metadata
- Authors
- Kalaydzhyan, T., & Yu, N.
- Venue
- Physical Review D
- Publisher
- American Physical Society (APS)
- Published
- 2017-10-06
- Volume
- 96
- Issue
- 7
- ISSN
- 2470-0010 (ISSN-L)
- 2470-0029
- OpenAlex
- W2616256683
- Cited by
- 30
- References
- 12
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.