Two-way silicon-neuron interface by electrical induction
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A nerve cell is placed onto a combined silicon microstructure of an insulated spot of doped silicon and an insulated-gate field-effect transistor. Voltage pulses are applied to the insulated spot. They elicit neural activity which in turn modulates the transistor. The bidirectional interface between the ionics of neurons and the electronics of silicon is based on electrical induction mediated by an electrochemically safe interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Neuron-Silicon Junction: A Retzius Cell of the Leech on an Insulated-Gate Field-Effect Transistor
Fromherz, P., Offenhäusser, A., Vetter, T., & Weis, J. (1991) · Science · doi:10.1126/science.1925540 · Cited by 563
Self-citationSilicon-neuron junction: capacitive stimulation of an individual neuron on a silicon chip.
Fromherz, P., & Stett, A. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.1670 · Cited by 167
Self-citationKovacs, G. T. A., Storment, C. W., Halks-Miller, M., Belczynski, C. R., Santina, C. C. D., Lewis, E. R., & Maluf, N. I. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293244 · Cited by 161
Cited by
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
“It is important to consider where the noise, or interference, is injected in the signal chain, as the implications on SNR will differ.”
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 348
The neurochip: a new multielectrode device for stimulating and recording from cultured neurons
Maher, M., Pine, J., Wright, J., & Tai, Y.-C. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00156-3 · Cited by 322
Zeck, G., & Fromherz, P. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.181348698 · Cited by 290
Self-citationSelective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Electrical multisite stimulation of the isolated chicken retina
Stett, A., Barth, W., Weiss, S., Haemmerle, H., & Zrenner, E. (2000) · Vision Research · doi:10.1016/s0042-6989(00)00005-5 · Cited by 259
Self-citationA method for spike sorting and detection based on wavelet packets and Shannon's mutual information
Hulata, E., Segev, R., & Ben-Jacob, E. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00032-8 · Cited by 201
“…networks cell cultures, hippocampal slices, and in vivo tissues by simultaneous measurement of the activity of many neurons using multichannel electrode arrays (Jimbo et al., 1993; Stenger and Mckenna, 1994; Camepari et al., 1997; Fromherz et al., 1997; Egert et al., 1998; Maher et al., 1999).”
MethodThe culture of neurons on silicon
Bayliss, S. C., Buckberry, L. D., Fletcher, I., & Tobin, M. J. (1999) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(98)00346-x · Cited by 93
Metadata
- Authors
- Stett, A., Müller, B., & Fromherz, P.
- Venue
- Physical Review E
- Publisher
- American Physical Society (APS)
- Published
- 1997-02-01
- Volume
- 55
- Issue
- 2
- Pages
- 1779-1782
- ISSN
- 1063-651X (ISSN-L)
- 1095-3787
- OpenAlex
- W2052155146
- Cited by
- 43
- References
- 3
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.