The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Improved Measurement of the Hydrogen1S–2STransition Frequency
Open accessAbstract
We have measured the 1S-2S transition frequency in atomic hydrogen via two-photon spectroscopy on a 5.8 K atomic beam. We obtain f(1S-2S) = 2,466,061,413,187,035 (10) Hz for the hyperfine centroid, in agreement with, but 3.3 times better than the previous result [M. Fischer et al., Phys. Rev. Lett. 92, 230802 (2004)]. The improvement to a fractional frequency uncertainty of 4.2 × 10(-15) arises mainly from an improved stability of the spectroscopy laser, and a better determination of the main systematic uncertainties, namely, the second order Doppler and ac and dc Stark shifts. The probe laser frequency was phase coherently linked to the mobile cesium fountain clock FOM via a frequency comb.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CODATA recommended values of the fundamental physical constants: 2006
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.633 · Cited by 952
Niering, M., Holzwarth, R., Reichert, J., Pokasov, P., Udem, T., Weitz, M., Hänsch, T. W., Lemonde, P., Santarelli, G., Abgrall, M., et al. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5496 · Cited by 560
Self-citationNew Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431
Self-citationFrequency of the Hydrogen Maser
ESSEN, L., DONALDSON, R. W., BANGHAM, M. J., & HOPE, E. G. (1971) · Nature · doi:10.1038/229110a0 · Cited by 315
Farley, J. W., & Wing, W. H. (1981) · Physical Review A · doi:10.1103/physreva.23.2397 · Cited by 305
Alnis, J., Matveev, A., Kolachevsky, N., Udem, T., & Hänsch, T. W. (2008) · Physical Review A · doi:10.1103/physreva.77.053809 · Cited by 295
Self-citationConfinement of antihydrogen for 1,000 seconds
The ALPHA Collaboration (2011) · Nature Physics · doi:10.1038/nphys2025 · Cited by 272
Bize, S., Laurent, P., Abgrall, M., Marion, H., Maksimovic, I., Cacciapuoti, L., Grünert, J., Vian, C., dos Santos, F. P., Rosenbusch, P., et al. (2004) · Comptes Rendus Physique · doi:10.1016/j.crhy.2004.09.003 · Cited by 90
Self-citationHaas, M., Jentschura, U. D., Keitel, C. H., Kolachevsky, N., Herrmann, M. G., Fendel, P., Fischer, M., Udem, T., Holzwarth, R., Hänsch, T. W., et al. (2006) · Physical Review A · doi:10.1103/physreva.73.052501 · Cited by 84
Self-citationSpectroscopy of atomic hydrogen: How is the Rydberg constant determined?
Biraben, F. (2009) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2009-01045-3 · Cited by 75
Bloch, P., Pavlopoulos, P., & Klapisch, R. (1987) · Springer eBooks · doi:10.1007/978-1-4684-5389-8 · Cited by 71
Accuracy of optical frequency comb generators and optical frequency interval divider chains
Udem, T., Reichert, J. C., Hänsch, T. W., & Kourogi, M. (1998) · Optics Letters · doi:10.1364/ol.23.001387 · Cited by 55
Self-citationContinuous-wave measurement of the hydrogen 1S-2Stransition frequency
McIntyre, D. H., Beausoleil, R. G., Foot, C. J., Hildum, E. A., Couillaud, B., & Hänsch, T. W. (1989) · Physical Review A · doi:10.1103/physreva.39.4591 · Cited by 51
Self-citationTesting electron boost invariance with 2 S − 1 S hydrogen spectroscopy
Altschul, B. (2010) · Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields · doi:10.1103/physrevd.81.041701 · Cited by 32
Low phase noise diode laser oscillator for 1S–2S spectroscopy in atomic hydrogen
Kolachevsky, N., Alnis, J., Parthey, C. G., Matveev, A., Landig, R., & Hänsch, T. W. (2011) · Optics Letters · doi:10.1364/ol.36.004299 · Cited by 31
Self-citationPhotoionization broadening of the 1S−2S transition in a beam of atomic hydrogen
Kolachevsky, N., Haas, M., Jentschura, U. D., Herrmann, M. G., Fendel, P., Fischer, M., Holzwarth, R., Udem, T., Keitel, C. H., & Hänsch, T. W. (2006) · Physical Review A · doi:10.1103/physreva.74.052504 · Cited by 14
Self-citation
Cited by
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
CODATA recommended values of the fundamental physical constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.035009 · Cited by 920
CODATA recommended values of the fundamental physical constants: 2018
Tiesinga, E., Mohr, P. J., Newell, D. B., & Taylor, B. N. (2021) · Reviews of Modern Physics · doi:10.1103/revmodphys.93.025010 · Cited by 908
Proton Structure from the Measurement of 2S-2P Transition Frequencies of Muonic Hydrogen
Antognini, A., Nez, F., Schuhmann, K., Amaro, F. D., Biraben, F., Cardoso, J. M. R., Covita, D. S., Dax, A., Dhawan, S., Diepold, M., et al. (2013) · Science · doi:10.1126/science.1230016 · Cited by 885
Self-citationA 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543
Self-citation
Metadata
- Authors
- Parthey, C. G., Matveev, A., Alnis, J., Bernhardt, B., Beyer, A., Holzwarth, R., Maistrou, A., Pohl, R., Predehl, K., Udem, T., Wilken, T., Kolachevsky, N., Abgrall, M., Rovera, D., Salomon, C., Laurent, P., & Hänsch, T. W.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2011-11-11
- Volume
- 107
- Issue
- 20
- Pages
- 203001-203001
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2150210656
- Cited by
- 423
- References
- 16
- FWCI
- 15.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.