Improved Measurement of the Hydrogen1S–2STransition Frequency
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
We have measured the 1S-2S transition frequency in atomic hydrogen via two-photon spectroscopy on a 5.8 K atomic beam. We obtain f(1S-2S) = 2,466,061,413,187,035 (10) Hz for the hyperfine centroid, in agreement with, but 3.3 times better than the previous result [M. Fischer et al., Phys. Rev. Lett. 92, 230802 (2004)]. The improvement to a fractional frequency uncertainty of 4.2 × 10(-15) arises mainly from an improved stability of the spectroscopy laser, and a better determination of the main systematic uncertainties, namely, the second order Doppler and ac and dc Stark shifts. The probe laser frequency was phase coherently linked to the mobile cesium fountain clock FOM via a frequency comb.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CODATA recommended values of the fundamental physical constants: 2006
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.633 · Cited by 952
Niering, M., Holzwarth, R., Reichert, J., Pokasov, P., Udem, T., Weitz, M., Hänsch, T. W., Lemonde, P., Santarelli, G., Abgrall, M., et al. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5496 · Cited by 560
Self-citationNew Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431
Self-citationFrequency of the Hydrogen Maser
ESSEN, L., DONALDSON, R. W., BANGHAM, M. J., & HOPE, E. G. (1971) · Nature · doi:10.1038/229110a0 · Cited by 315
Farley, J. W., & Wing, W. H. (1981) · Physical Review A · doi:10.1103/physreva.23.2397 · Cited by 305
Alnis, J., Matveev, A., Kolachevsky, N., Udem, T., & Hänsch, T. W. (2008) · Physical Review A · doi:10.1103/physreva.77.053809 · Cited by 295
Self-citationConfinement of antihydrogen for 1,000 seconds
The ALPHA Collaboration (2011) · Nature Physics · doi:10.1038/nphys2025 · Cited by 272
Haas, M., Jentschura, U. D., Keitel, C. H., Kolachevsky, N., Herrmann, M. G., Fendel, P., Fischer, M., Udem, T., Holzwarth, R., Hänsch, T. W., et al. (2006) · Physical Review A · doi:10.1103/physreva.73.052501 · Cited by 84
Self-citationBize, S., Laurent, P., Abgrall, M., Marion, H., Maksimovic, I., Cacciapuoti, L., Grünert, J., Vian, C., Pereira dos Santos, F., Rosenbusch, P., et al. (2004) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2004.09.003 · Cited by 82
Self-citationSpectroscopy of atomic hydrogen: How is the Rydberg constant determined?
Biraben, F. (2009) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2009-01045-3 · Cited by 75
Cited by
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
CODATA recommended values of the fundamental physical constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.035009 · Cited by 920
CODATA recommended values of the fundamental physical constants: 2018
Tiesinga, E., Mohr, P. J., Newell, D. B., & Taylor, B. N. (2021) · Reviews of Modern Physics · doi:10.1103/revmodphys.93.025010 · Cited by 908
Proton Structure from the Measurement of 2S-2P Transition Frequencies of Muonic Hydrogen
Antognini, A., Nez, F., Schuhmann, K., Amaro, F. D., Biraben, F., Cardoso, J. M. R., Covita, D. S., Dax, A., Dhawan, S., Diepold, M., et al. (2013) · Science · doi:10.1126/science.1230016 · Cited by 885
Self-citationA 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543
Self-citationQCD and strongly coupled gauge theories: challenges and perspectives
Brambilla, N., Eidelman, S., Foka, P., Gardner, S., Kronfeld, A. S., Alford, M. G., Alkofer, R., Butenschoen, M., Cohen, T. D., Erdmenger, J., et al. (2014) · The European Physical Journal C · doi:10.1140/epjc/s10052-014-2981-5 · Cited by 540
The Rydberg constant and proton size from atomic hydrogen
Beyer, A., Maisenbacher, L., Matveev, A., Pohl, R., Khabarova, K., Grinin, A., Lamour, T., Yost, D. C., Hänsch, T. W., Kolachevsky, N., et al. (2017) · Science · doi:10.1126/science.aah6677 · Cited by 383
Self-citationMuonic Hydrogen and the Proton Radius Puzzle
Pohl, R., Gilman, R., Miller, G. A., & Pachucki, K. (2013) · Annual Review of Nuclear and Particle Science · doi:10.1146/annurev-nucl-102212-170627 · Cited by 354
Self-citationA measurement of the atomic hydrogen Lamb shift and the proton charge radius
Bezginov, N., Valdez, T., Horbatsch, M., Marsman, A., Vutha, A. C., & Hessels, E. A. (2019) · Science · doi:10.1126/science.aau7807 · Cited by 339
Optical-Frequency Transfer over a Single-Span 1840 km Fiber Link
Droste, S., Ozimek, F., Udem, T., Predehl, K., Hänsch, T. W., Schnatz, H., Grosche, G., & Holzwarth, R. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.110801 · Cited by 315
Self-citationCODATA Recommended Values of the Fundamental Physical Constants: 2018
Tiesinga, E., Mohr, P. J., Newell, D. B., & Taylor, B. N. (2021) · Journal of Physical and Chemical Reference Data · doi:10.1063/5.0064853 · Cited by 299
Progress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Self-citationMehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“…in this regime that were necessary for high precision spectroscopic application such as the determination of the hydrogen 1S – 2S two-photon transition frequency (Niering et al 2000, Fischer et al 2004, Parthey et al 2011) or the 40 Ca + clock transition frequency (Chwalla et al 2009).”
Plasma and trap-based techniques for science with positrons
Danielson, J. R., Dubin, D. H. E., Greaves, R. G., & Surko, C. M. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.247 · Cited by 254
CODATA Recommended Values of the Fundamental Physical Constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.4954402 · Cited by 252
Transportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238
Precision Measurement of the Hydrogen1S−2SFrequency via a 920-km Fiber Link
Matveev, A., Parthey, C. G., Predehl, K., Alnis, J., Beyer, A., Holzwarth, R., Udem, T., Wilken, T., Kolachevsky, N., Abgrall, M., et al. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.230801 · Cited by 227
Self-citationLim, J., Savchenkov, A. A., Dale, E., Liang, W., Eliyahu, D., Ilchenko, V., Matsko, A. B., Maleki, L., & Wong, C. W. (2017) · Nature Communications · doi:10.1038/s41467-017-00021-9 · Cited by 219
“(2) for TE mode (dotted line) are plotted together.”
BackgroundA source of antihydrogen for in-flight hyperfine spectroscopy
Kuroda, N., Ulmer, S., Murtagh, D. J., Van Gorp, S., Nagata, Y., Diermaier, M., Federmann, S., Leali, M., Malbrunot, C., Mascagna, V., et al. (2014) · Nature Communications · doi:10.1038/ncomms4089 · Cited by 173
Experimental progress in positronium laser physics
Cassidy, D. B. (2018) · The European Physical Journal D · doi:10.1140/epjd/e2018-80721-y · Cited by 171
Observation of the 1S–2S transition in trapped antihydrogen
Ahmadi, M., Alves, B. X. R., Baker, C. J., Bertsche, W., Butler, E., Capra, A., Carruth, C., Cesar, C. L., Charlton, M., Cohen, S., et al. (2017) · Nature · doi:10.1038/nature21040 · Cited by 162
Fundamental Vibration of Molecular Hydrogen
Dickenson, G. D., Niu, M. L., Salumbides, E. J., Komasa, J., Eikema, K. S. E., Pachucki, K., & Ubachs, W. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.193601 · Cited by 162
Characterization of the 1S–2S transition in antihydrogen
Ahmadi, M., Alves, B. X. R., Baker, C. J., Bertsche, W., Capra, A., Carruth, C., Cesar, C. L., Charlton, M., Cohen, S., Collister, R., et al. (2018) · Nature · doi:10.1038/s41586-018-0017-2 · Cited by 160
High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.263004 · Cited by 154
A parts-per-billion measurement of the antiproton magnetic moment
Smorra, C., Sellner, S., Borchert, M. J., Harrington, J. A., Higuchi, T., Nagahama, H., Tanaka, T., Mooser, A., Schneider, G., Bohman, M., et al. (2017) · Nature · doi:10.1038/nature24048 · Cited by 149
High-precision comparison of the antiproton-to-proton charge-to-mass ratio
Ulmer, S., Smorra, C., Mooser, A., Franke, K., Nagahama, H., Schneider, G., Higuchi, T., Van Gorp, S., Blaum, K., Matsuda, Y., et al. (2015) · Nature · doi:10.1038/nature14861 · Cited by 147
“In summary, the ratio has to be corrected by2117(26) parts per trillion, leading to our final result”
BackgroundPrecision spectroscopy of helium in a magic wavelength optical dipole trap
Rengelink, R. J., van der Werf, Y., Notermans, R. P. M. J. W., Jannin, R., Eikema, K. S. E., Hoogerland, M. D., & Vassen, W. (2018) · Nature Physics · doi:10.1038/s41567-018-0242-5 · Cited by 66
High-Precision Determination of g Factors and Masses of Ne209+ and Ne229+
Heiße, F., Door, M., Sailer, T., Filianin, P., Herkenhoff, J., König, C. M., Kromer, K., Lange, D., Morgner, J., Rischka, A., et al. (2023) · Physical Review Letters · doi:10.1103/physrevlett.131.253002 · Cited by 18
Metadata
- Authors
- Parthey, C. G., Matveev, A., Alnis, J., Bernhardt, B., Beyer, A., Holzwarth, R., Maistrou, A., Pohl, R., Predehl, K., Udem, T., Wilken, T., Kolachevsky, N., Abgrall, M., Rovera, D., Salomon, C., Laurent, P., & Hänsch, T. W.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2011-11-11
- Volume
- 107
- Issue
- 20
- Pages
- 203001-203001
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2150210656
- Cited by
- 423
- References
- 16
- FWCI
- 15.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.