High-Accuracy Measurement of the Blackbody Radiation Frequency Shift of the Ground-State Hyperfine Transition inCs133
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We report a high-accuracy direct measurement of the blackbody radiation shift of the 133Cs ground-state hyperfine transition. This frequency shift is one of the largest systematic frequency biases encountered in realizing the current definition of the International System of Units (SI) second. Uncertainty in the blackbody radiation frequency shift correction has led to its being the focus of intense theoretical effort by a variety of research groups. Our experimental measurement of the shift used three primary frequency standards operating at different temperatures. We achieved an uncertainty a factor of five smaller than the previous best direct measurement. These results tend to validate the claimed accuracy of the recently calculated values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Self-citationParker, T. E., Jefferts, S. R., Heavner, T. P., & Donley, E. A. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/013 · Cited by 220
Self-citation
Cited by
First accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205
Self-citationAtomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.260801 · Cited by 137
Liquid-Nitrogen-Cooled Ca + Optical Clock with Systematic Uncertainty of 3×10−18
Huang, Y., Zhang, B., Zeng, M., Hao, Y., Ma, Z., Zhang, H., Guan, H., Chen, Z., Wang, M., & Gao, K. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.034041 · Cited by 82
Metadata
- Authors
- Jefferts, S. R., Heavner, T. P., Parker, T. E., Shirley, J. H., Donley, E. A., Ashby, N., Levi, F., Calonico, D., & Costanzo, G. A.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2014-02-07
- Volume
- 112
- Issue
- 5
- Pages
- 050801-050801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2032173190
- Cited by
- 36
- References
- 2
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.