Ordered and Disordered Patterns in Two-Phase Flows in Microchannels
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We show that wetting properties crucially control the patterns in two-phase flows of immiscible fluids in microchannels. Ordered patterns, continuously entrained by the flow, are obtained when one phase completely wets the walls, while disordered patterns, intermittently adhering to the channel walls, are unavoidably produced when wetting is partial. A lower limit for the channel sizes capable of generating well structured objects (drops, pears, pearl necklaces, ...) is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Interfacial Tension Driven Monodispersed Droplet Formation from Microfabricated Channel Array
Sugiura, S., Nakajima, M., Iwamoto, S., & Seki, M. (2001) · Langmuir · doi:10.1021/la010342y · Cited by 439
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Geometrically Mediated Breakup of Drops in Microfluidic Devices
Link, D. R., Anna, S. L., Weitz, D. A., & Stone, H. A. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.054503 · Cited by 1,202
Dynamics of microfluidic droplets
Baroud, C. N., Gallaire, F., & Dangla, R. (2010) · Lab on a Chip · doi:10.1039/c001191f · Cited by 1,067
Multiphase microfluidics: from flow characteristics to chemical and materials synthesis
Günther, A., & Jensen, K. F. (2006) · Lab Chip · doi:10.1039/b609851g · Cited by 983
Microfluidic methods for generating continuous droplet streams
Christopher, G. F., & Anna, S. L. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/19/r01 · Cited by 860
Transition from squeezing to dripping in a microfluidic T-shaped junction
DE MENECH, M., GARSTECKI, P., JOUSSE, F., & STONE, H. A. (2008) · Journal of Fluid Mechanics · doi:10.1017/s002211200700910x · Cited by 728
Okushima, S., Nisisako, T., Torii, T., & Higuchi, T. (2004) · Langmuir · doi:10.1021/la0480336 · Cited by 656
Formation of monodisperse bubbles in a microfluidic flow-focusing device
Garstecki, P., Gitlin, I., DiLuzio, W., Whitesides, G. M., Kumacheva, E., & Stone, H. A. (2004) · Applied Physics Letters · doi:10.1063/1.1796526 · Cited by 641
Microdroplets: A sea of applications?
Huebner, A., Sharma, S., Srisa-Art, M., Hollfelder, F., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b806405a · Cited by 619
Controlled Synthesis of Nonspherical Microparticles Using Microfluidics
Dendukuri, D., Tsoi, K., Hatton, T. A., & Doyle, P. S. (2005) · Langmuir · doi:10.1021/la047368k · Cited by 482
Multiphase flow microfluidics for the production of single or multiple emulsions for drug delivery
Zhao, C.-X. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.05.009 · Cited by 451
Wörner, M. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-0940-8 · Cited by 438
Dripping and jetting in microfluidic multiphase flows applied to particle and fibre synthesis
Nunes, J. K., Tsai, S. S. H., Wan, J., & Stone, H. A. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/11/114002 · Cited by 406
Zhao, C.-X., & Middelberg, A. P. J. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.038 · Cited by 397
Droplet Control for Microfluidics
Joanicot, M., & Ajdari, A. (2005) · Science · doi:10.1126/science.1112615 · Cited by 379
An Axisymmetric Flow‐Focusing Microfluidic Device
Takeuchi, S., Garstecki, P., Weibel, D. B., & Whitesides, G. M. (2005) · Advanced Materials · doi:10.1002/adma.200401738 · Cited by 370
Effects of viscosity on droplet formation and mixing in microfluidic channels
Tice, J. D., Lyon, A. D., & Ismagilov, R. F. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.11.024 · Cited by 360
Droplet microfluidics: recent developments and future applications
Casadevall i Solvas, X., & deMello, A. (2011) · Chem. Commun. · doi:10.1039/c0cc02474k · Cited by 353
Preparation of highly monodisperse droplet in a T‐junction microfluidic device
Xu, J. H., Li, S. W., Tan, J., Wang, Y. J., & Luo, G. S. (2006) · AIChE Journal · doi:10.1002/aic.10924 · Cited by 335
Controlled formulation of monodisperse double emulsions in a multiple-phase microfluidic system
Nisisako, T., Okushima, S., & Torii, T. (2005) · Soft Matter · doi:10.1039/b501972a · Cited by 335
Fu, T., Wu, Y., Ma, Y., & Li, H. Z. (2012) · Chemical Engineering Science · doi:10.1016/j.ces.2012.08.039 · Cited by 312
Droplets Formation and Merging in Two-Phase Flow Microfluidics
Gu, H., Duits, M. H. G., & Mugele, F. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12042572 · Cited by 312
Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
Choi, S., Goryll, M., Sin, L. Y. M., Wong, P. K., & Chae, J. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0638-8 · Cited by 270
Bartolo, D., Degré, G., Nghe, P., & Studer, V. (2008) · Lab Chip · doi:10.1039/b712368j · Cited by 265
Microfluidic consecutive flow-focusing droplet generators
Seo, M., Paquet, C., Nie, Z., Xu, S., & Kumacheva, E. (2007) · Soft Matter · doi:10.1039/b700687j · Cited by 263
Continuous Microfluidic Reactors for Polymer Particles
Seo, M., Nie, Z., Xu, S., Mok, M., Lewis, P. C., Graham, R., & Kumacheva, E. (2005) · Langmuir · doi:10.1021/la050519e · Cited by 253
Droplet-based single cell RNAseq tools: a practical guide
Salomon, R., Kaczorowski, D., Valdes-Mora, F., Nordon, R. E., Neild, A., Farbehi, N., Bartonicek, N., & Gallego-Ortega, D. (2019) · Lab on a Chip · doi:10.1039/c8lc01239c · Cited by 109
Metadata
- Authors
- Dreyfus, R., Tabeling, P., & Willaime, H.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2003-04-11
- Volume
- 90
- Issue
- 14
- Pages
- 144505-144505
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2010241268
- Cited by
- 404
- References
- 3
- FWCI
- 24.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.