The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Nanoscale Resolution in the Focal Plane of an Optical Microscope
Open accessAbstract
Utilizing single fluorescent molecules as probes, we prove the ability of a far-field microscope to attain spatial resolution down to 16 nm in the focal plane, corresponding to about 1/50 of the employed wavelength. The optical bandwidth expansion by nearly an order of magnitude is realized by a saturated depletion through stimulated emission of the molecular fluorescent state. We demonstrate that en route to the molecular scale, the resolving power increases with the square root of the saturation level, which constitutes a new law regarding the resolution of an emerging class of far-field light microscopes that are not limited by diffraction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Self-citationBeiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung
Abbe, E. (1873) · Archiv für Mikroskopische Anatomie · doi:10.1007/bf02956173 · Cited by 2,724
Sharper Focus for a Radially Polarized Light Beam
Dorn, R., Quabis, S., & Leuchs, G. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.233901 · Cited by 2,125
Quantum Interferometric Optical Lithography: Exploiting Entanglement to Beat the Diffraction Limit
Boto, A. N., Kok, P., Abrams, D. S., Braunstein, S. L., Williams, C. P., & Dowling, J. P. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2733 · Cited by 1,517
High-Resolution Near-Field Raman Microscopy of Single-Walled Carbon Nanotubes
Hartschuh, A., Sánchez, E. J., Xie, X., & Novotný, L. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.095503 · Cited by 870
Super-gain antennas and optical resolving power
Di Francia, G. T. (1952) · Il Nuovo Cimento · doi:10.1007/bf02903413 · Cited by 547
Focal Spots of Size λ / 23 Open Up Far-Field Florescence Microscopy at 33 nm Axial Resolution
Dyba, M., & Hell, S. W. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.163901 · Cited by 364
Self-citationHigh Resolution 3D X-Ray Diffraction Microscopy
Miao, J., Ishikawa, T., Johnson, B., Anderson, E. H., Lai, B., & Hodgson, K. O. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.088303 · Cited by 331
Klar, T. A., Engel, E., & Hell, S. W. (2001) · Physical Review E · doi:10.1103/physreve.64.066613 · Cited by 276
Self-citationStrategy for far-field optical imaging and writing without diffraction limit
Hell, S. W. (2004) · Physics Letters A · doi:10.1016/j.physleta.2004.03.082 · Cited by 177
Self-citation
Cited by
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
“the ‘zero’, need not be formed as a doughnut; it could also be a groove [69, 78, 81] in which case the resolution would be improved just in the direction perpendicular to the groove.”
BackgroundMethodInfluentialSelf-citationNovotny, L., & van Hulst, N. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.237 · Cited by 2,649
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Metadata
- Authors
- Westphal, V., & Hell, S. W.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2005-04-15
- Volume
- 94
- Issue
- 14
- Pages
- 143903-143903
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1972259822
- Cited by
- 502
- References
- 10
- FWCI
- 20.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.